background image

11

Section 61250110L1-5, Issue 4

61250110L1-5D

4. TESTING
Self Test

When inserted into a powered-up backplane the
HD-10 performs a self test. Results are seen on the
faceplate LED: Red indicates Fail, Green indicates
Pass. Refer to Table 2.  Self Test status is also
available via the DB-9 interface.

Initiated Tests

The HD-10 supports testing and performance
monitoring at both the DS0 and DS1 levels. The
following types of loopbacks are supported on the DS1
level:

• local bilateral loopback

• local loopback

• payload loopback

• line loopback

• remote payload loopback

• remote line loopback

NOTE

DS1 level loopbacks are intrusive and will
disrupt channel bank service.

Local Bilateral Loopback

A local bilateral loopback test can be activated in both
SF and ESF modes by pressing the faceplate TEST
button. The test simultaneously places a loopback in
both the carrier and loop directions on all 10 BRI
circuits. When the bilateral loopback is active the
faceplate LBK LED will go On. Pressing the TEST
button a second time will deactivate the loopback test
returning the HD-10 to normal operation, the LBK
LED will go Off.

This loopback can also be invoked via the DB-9
interface. To initiate a local bilateral loopback test,
navigate the menu as follows:

TEST >> BILATERAL LOOPBACK

Then select ON to activate the test. The LBK LED
turns On solid yellow to indicate that the TA HD-10 is
in test mode.

To deactivate bilateral loopback, navigate the menu as
follows:

TEST >> BILATERAL LOOPBACK

Then select OFF. The LBK LED will go Off
indicating the test is terminated.

Local Loopback

A local loopback bridges the T1 line across the
receive pair to the transmit pair, isolating the bank
from the T1 line. This allows for internal bank testing
and individual card testing, and provides a baseline for
T1 line testing.

To initiate a local loopback, navigate the menu as
follows:

TEST >> DSX LOOPBACKS >> CURRENT
LOOPBACK

Then select LOCAL LOOPBACK to activate the
desired test. The  HD-10 will return to the previous
screen to show the status of the test. The LBK LED
will Flash to indicate the HD-10 is in test mode.

To deactivate remote loopbacks, navigate the menu as
follows:

TEST >> DSX LOOPBACKS >> CURRENT
LOOPBACK

To disable the local loopback select NONE. The HD-
10 will return to the previous screen to show the status
of the test. The LBK LED will turn Off indicating the
test is terminated.

Payload and Line Loopbacks (ESF and SF)

A payload loopback from the HD-10 results in only
the payload data being looped back to the remote T1
multiplexer. Framing is regenerated by the local
HD-10.

A line loopback from the HD-10 results in a full
loopback. Framing is not regenerated by the local
HD-10 but instead is echoed back to the remote T1
multiplexer.

To initiate either a payload or line loopback, navigate
the menu as follows:

TEST >> DSX LOOPBACKS >> CURRENT
LOOPBACK

Then select either PAYLOAD LOOPBACK or LINE
LOOPBACK to activate the desired test. The HD-10
will return to the previous screen to show the status of
the test. The LBK LED will Flash indicating the
HD-10 is in test mode.

To deactivate the loopbacks, navigate through the
menu as follows:

TEST >> DSX LOOPBACKS >> CURRENT
LOOPBACK

To disable either the payload or line loopback select
NONE. The HD-10 will return to the previous screen
to show the status of the test. The LBK LED will go
Off indicating the test is terminated.

Содержание HD-10 BRI MUX

Страница 1: ... NWT 000829 Provides T1 interface compatibility with DSX 1 and DS1 signals Supports superframe and extended superframe formats Supports AMI and B8ZS line coding Provides DB 9 terminal interface for provisioning testing and performance monitoring Provides bilateral loopback capability activated from faceplate switch Provides Local Loop External and CAU timing options Provides an alarm relay and ala...

Страница 2: ...r seats firmly into the backplane A similar process applies to the standalone housing CAUTION This product is intended for installation in Restricted Access Locations only and is intended to be installed in equipment with a Type B or E installation code C A U T I O N SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED Connections All input and output to the HD ...

Страница 3: ...e with any D4 channel bank that is compliant with TR NWT 000397 and configured for D4 terminal with D4 counting The 10 DSL mode is compatible with any channel bank that supports the ADTRAN 4 1 TDM format such as the ADTRAN BR1 10 Channel Bank The HD 10 does not support D1D counting SLC Mode 1 or SLC Mode 3 LED Indication The HD 10 faceplate has 13 LEDs to indicate the operational status of the uni...

Страница 4: ...i f n o c n e h W t n e r r u c g n i l a e s s l o r t n o c 5 4 W S e d o m T L U L n I M D T e c r u o S e c i f f O m e d n a T r o f d e r u g i f n o c n e h W d e d i v o r p e b t s u m t n e r r u c g n i l a e s J D A d e l b a s i d e b d l u o h s d n a d e r i u q e r t o n s i t n e r r u c g n i l a e s e b d l u o h s s e n o t p u e k a w c i d o i r e P e n o t p u e k a w c i d ...

Страница 5: ... Y g n i h s a l f w o l l e Y e v i t c a s k c a b p o o l 1 T o n l a m r o N e v i t c a k c a b p o o l 1 T l a r e t a l i b l a c o L g n i d n a m m o C r o e d o m F S E k c a b p o o l d e t a i t i n i e t o m e r n i e c a f r e t n i 1 X S D r o 1 S D e d o m F S E e c a f r e t n i 1 X S D r o 1 S D e h t r e v o t i n u r e h t o n a o t k c a b p o o l e t o m e r a L S D 0 1 1 f f...

Страница 6: ...roceed with the desired action To make a selection press the number on the keyboard for the desired category then press enter Specific screen displays are on the pages following the menu tree and as listed below Main Menu below DSL Test Menu Testing for DSL 1 DSX Performance DSL Performance in CUSTOMER Direction DSX Performance Screen The DSX Performance Screen records error data from both the loc...

Страница 7: ... ft 5 533 655 ft 6 7 5 dB 7 15 dB 8 22 5 dB 1 ESF 2 SF 1 B8ZS 2 AMI 5 Framing 6 Line Code 1 OFF 2 ON 7 U TMG 2 Provisioning 1 DSX Provisioning 2 ISDN Provisioning 1 Operating Mode 2 Sealing Current 3 Tandem Feature 1 LULT 2 LUNT 1 Off 2 On 1 Off 2 On 4 Individual DSL Settings 1 Change Current DSL 1 DSL 1 2 DSL 2 3 DSL 3 4 DSL 4 5 DSL 5 6 DSL 6 7 DSL 7 8 DSL 8 9 DSL 9 10 DSL 10 2 ZBS 3 Service 1 Of...

Страница 8: ... minute registers Far end ES and SES data 24 hour and 15 minute registers Active Alarm Status DSL Performance in customer or network direction Current hourly BE ES SES data Current daily ES SES data Previous hourly BE ES 8 hours SES data Previous daily ES SES data 2 ISDN Performance E220 HD 10 Menu Structure Page 2 of 2 Test Status Test Commands Test Error Bits Total Bits BER Lost Sync Count Enter...

Страница 9: ... NT1 0 0 0 0000E 00 IDLE 7 DSL 7 B1 NT1 0 0 0 0000E 00 IDLE 8 DSL 8 B1 NT1 0 0 0 0000E 00 IDLE 9 DSL 9 B1 NT1 0 0 0 0000E 00 IDLE 10 DSL 10 B1 NT1 0 0 0 0000E 00 IDLE Selection System Help Screen Adtran HD 10 ISDN BRI Mux Active Alarm None Terminal baud rate 9600 ISDN E220 HD 10 BRI Mux Testing for DSL 1 Test NO TEST ACTIVE Selected B1 loopback to NT1 Enter 1 7 for ADR 1 7 N NT1 Error bits 0 A 2D ...

Страница 10: ... 0 0 0 0 0 0 0 0 0 Hour 6 ES 0 0 0 0 0 0 0 0 0 0 Hour 7 ES 0 0 0 0 0 0 0 0 0 0 Hour 8 ES 0 0 0 0 0 0 0 0 0 0 ENTER show NETWORK Direction System Help Screen e c n a m r o f r e P X S D s r e t s i g e r r u o h 4 2 s r e t s i g e r e t u n i m 5 1 e t a d S E S E S e m i t S E S E S e m i t S E S E S e m i t S E S E S R A E N D N E A T A D w o n 0 0 0 0 0 0 0 0 0 0 w o n 0 0 0 0 0 0 0 0 2 0 0 4 h...

Страница 11: ...oopback bridges the T1 line across the receive pair to the transmit pair isolating the bank from the T1 line This allows for internal bank testing and individual card testing and provides a baseline for T1 line testing To initiate a local loopback navigate the menu as follows TEST DSX LOOPBACKS CURRENT LOOPBACK Then select LOCAL LOOPBACK to activate the desired test The HD 10 will return to the pr...

Страница 12: ...an also activate a loopback in a downstream device An onboard 2047 pattern generator and error checker allow all 10 circuits of the HD 10 to be tested simultaneously The loopback test using the internal pattern generator is controlled via the faceplate DB 9 interface ISDN Loopback and BERT Testing Network loopback in the customer direction can be initiated from the DB 9 interface The 2047 pattern ...

Страница 13: ...vigate the menu as follows PERFORMANCE DSX PERFORMANCE The DSX Performance screen provides the following PM History in both the Near End and Far End Directions Errored Second and Severely Errored Second data 24 Hour and 15 Minute Registers To see the local Performance Monitoring of all 10 ISDN DSLs navigate through the menu as follows PERFORMANCE ISDN PERFORMANCE The ISDN Performance screen provid...

Страница 14: ...u t a t s L S D l a c i n a h c e M e z i S t h g i e W g n i t n u o M g n i t n u o m l a t n o z i r o h h g i h 8 3 1 x p e e d 2 1 0 1 x e d i w 2 1 5 z o 6 3 1 s b l 5 8 0 g n i s u o h e n o l a d n a t s r o f l e h s 0 1 D H s e d o C n o i t a r u g i f n o C C P e d o C r e w o P C T e d o C s n o i t a c i n u m m o c e l e T C I e d o C n o i t a l l a t s n I C T U O F N I X T U O X ...

Отзывы: