Section 61250110L1-5, Issue 4

61250110L1-5D

Section 61250110L1-5D

Issue 4, December 2000

CLEI Code # NDPMAK0E_ _

E220

HD-10 BRI MUX

Installation and Maintenance

1. GENERAL

This practice provides installation and maintenance
procedures for the ADTRAN E220 HD-10 BRI MUX
(

Figure 1

).

A listing of part numbers for relevant devices and
documents referenced in this Practice is in the
Specifications table.

Revision History

Document has been revised to show default switch
settings and add U-TMG mode.

Features

The HD-10 BRI MUX features include the following:

• Provides ten ISDN U-interfaces that meet all

Layer 1 requirements as specified in
ANSI T1.601-1992.

• Responds to B1, B2, and 2B+D loopbacks

through the embedded operations channel.

Figure 1.  HD-10 BRI MUX

Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.

• Provides DC test signature as specified in

TR-NWT-000397 to identify either LULT or
LUNT termination.

• Provides performance monitoring of Layer 1

facilities as specified in TR-NWT-000397 and
TR-NWT-000829.

• Provides T1 interface compatibility with DSX-1

and DS1 signals.

• Supports superframe and extended superframe

formats.

• Supports AMI and B8ZS line coding.

• Provides DB-9 terminal interface for

provisioning, testing, and performance
monitoring.

• Provides bilateral loopback capability activated

from faceplate switch.

• Provides Local, Loop, External, and CAU timing

options.

• Provides an alarm relay and alarm cutoff switch.

• Provides bank alarm LED for indicating bank

alarm conditions.

• Compliant with FCC, NEBS Level 3, and UL.

O

N

1 2 3 4

5 6 7

SW3

NT
TDM
8DSL
SF
AMI
DIS

LT

ADJ

10DSL

ESF

B8ZS

ZBS EN

1
2
3

J1

1
2
3

JP1

TERM

DSL

PWR

1250110L1

HD-10

BRI MUX

ACO

T
E
S
T

NT
TDM
8DSL
SF
AMI
DIS

LT

ADJ

10DLS

ESF

B8ZS

ZBS EN

ALM

LBK

1

2

3

4

5

6

7

8

9

10

TEST

SW4

Tables

Table 1.  Backplane Pinout Identification .......................... 2
Table 2.  DIP Switch Options ............................................. 4
Table 3.  LED Indication ..................................................... 5
Table 4.  HD-10 Specifications ......................................... 14

Figures

Figure 1.  HD-10 BRI MUX ............................................... 1
Figure 2.  Main Menu ......................................................... 6
Figure 3.  HD-10 Provisioning Menu Part 1 ....................... 7
Figure 4.  HD-10 Provisioning Menu Part 2 ....................... 8
Figure 5.  DSL Test Menu .................................................. 9
Figure 6.  Testing for DSL 1 ............................................... 9
Figure 7.  DSX Performance ............................................. 10
Figure 8.  DSL Performance in Customer Direction ........ 10

CONTENTS

1. GENERAL ...................................................................... 1
2. INSTALLATION ........................................................... 2
3. OPERATION .................................................................. 3
4. TESTING ...................................................................... 11
5. SPECIFICATIONS ....................................................... 13
6. MAINTENANCE ......................................................... 13
7. WARRANTY AND CUSTOMER SERVICE ............. 13

Содержание HD-10 BRI MUX

Страница 1: ... NWT 000829 Provides T1 interface compatibility with DSX 1 and DS1 signals Supports superframe and extended superframe formats Supports AMI and B8ZS line coding Provides DB 9 terminal interface for provisioning testing and performance monitoring Provides bilateral loopback capability activated from faceplate switch Provides Local Loop External and CAU timing options Provides an alarm relay and ala...

Страница 2: ...r seats firmly into the backplane A similar process applies to the standalone housing CAUTION This product is intended for installation in Restricted Access Locations only and is intended to be installed in equipment with a Type B or E installation code C A U T I O N SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED Connections All input and output to the HD ...

Страница 3: ...e with any D4 channel bank that is compliant with TR NWT 000397 and configured for D4 terminal with D4 counting The 10 DSL mode is compatible with any channel bank that supports the ADTRAN 4 1 TDM format such as the ADTRAN BR1 10 Channel Bank The HD 10 does not support D1D counting SLC Mode 1 or SLC Mode 3 LED Indication The HD 10 faceplate has 13 LEDs to indicate the operational status of the uni...

Страница 4: ...i f n o c n e h W t n e r r u c g n i l a e s s l o r t n o c 5 4 W S e d o m T L U L n I M D T e c r u o S e c i f f O m e d n a T r o f d e r u g i f n o c n e h W d e d i v o r p e b t s u m t n e r r u c g n i l a e s J D A d e l b a s i d e b d l u o h s d n a d e r i u q e r t o n s i t n e r r u c g n i l a e s e b d l u o h s s e n o t p u e k a w c i d o i r e P e n o t p u e k a w c i d ...

Страница 5: ... Y g n i h s a l f w o l l e Y e v i t c a s k c a b p o o l 1 T o n l a m r o N e v i t c a k c a b p o o l 1 T l a r e t a l i b l a c o L g n i d n a m m o C r o e d o m F S E k c a b p o o l d e t a i t i n i e t o m e r n i e c a f r e t n i 1 X S D r o 1 S D e d o m F S E e c a f r e t n i 1 X S D r o 1 S D e h t r e v o t i n u r e h t o n a o t k c a b p o o l e t o m e r a L S D 0 1 1 f f...

Страница 6: ...roceed with the desired action To make a selection press the number on the keyboard for the desired category then press enter Specific screen displays are on the pages following the menu tree and as listed below Main Menu below DSL Test Menu Testing for DSL 1 DSX Performance DSL Performance in CUSTOMER Direction DSX Performance Screen The DSX Performance Screen records error data from both the loc...

Страница 7: ... ft 5 533 655 ft 6 7 5 dB 7 15 dB 8 22 5 dB 1 ESF 2 SF 1 B8ZS 2 AMI 5 Framing 6 Line Code 1 OFF 2 ON 7 U TMG 2 Provisioning 1 DSX Provisioning 2 ISDN Provisioning 1 Operating Mode 2 Sealing Current 3 Tandem Feature 1 LULT 2 LUNT 1 Off 2 On 1 Off 2 On 4 Individual DSL Settings 1 Change Current DSL 1 DSL 1 2 DSL 2 3 DSL 3 4 DSL 4 5 DSL 5 6 DSL 6 7 DSL 7 8 DSL 8 9 DSL 9 10 DSL 10 2 ZBS 3 Service 1 Of...

Страница 8: ... minute registers Far end ES and SES data 24 hour and 15 minute registers Active Alarm Status DSL Performance in customer or network direction Current hourly BE ES SES data Current daily ES SES data Previous hourly BE ES 8 hours SES data Previous daily ES SES data 2 ISDN Performance E220 HD 10 Menu Structure Page 2 of 2 Test Status Test Commands Test Error Bits Total Bits BER Lost Sync Count Enter...

Страница 9: ... NT1 0 0 0 0000E 00 IDLE 7 DSL 7 B1 NT1 0 0 0 0000E 00 IDLE 8 DSL 8 B1 NT1 0 0 0 0000E 00 IDLE 9 DSL 9 B1 NT1 0 0 0 0000E 00 IDLE 10 DSL 10 B1 NT1 0 0 0 0000E 00 IDLE Selection System Help Screen Adtran HD 10 ISDN BRI Mux Active Alarm None Terminal baud rate 9600 ISDN E220 HD 10 BRI Mux Testing for DSL 1 Test NO TEST ACTIVE Selected B1 loopback to NT1 Enter 1 7 for ADR 1 7 N NT1 Error bits 0 A 2D ...

Страница 10: ... 0 0 0 0 0 0 0 0 0 Hour 6 ES 0 0 0 0 0 0 0 0 0 0 Hour 7 ES 0 0 0 0 0 0 0 0 0 0 Hour 8 ES 0 0 0 0 0 0 0 0 0 0 ENTER show NETWORK Direction System Help Screen e c n a m r o f r e P X S D s r e t s i g e r r u o h 4 2 s r e t s i g e r e t u n i m 5 1 e t a d S E S E S e m i t S E S E S e m i t S E S E S e m i t S E S E S R A E N D N E A T A D w o n 0 0 0 0 0 0 0 0 0 0 w o n 0 0 0 0 0 0 0 0 2 0 0 4 h...

Страница 11: ...oopback bridges the T1 line across the receive pair to the transmit pair isolating the bank from the T1 line This allows for internal bank testing and individual card testing and provides a baseline for T1 line testing To initiate a local loopback navigate the menu as follows TEST DSX LOOPBACKS CURRENT LOOPBACK Then select LOCAL LOOPBACK to activate the desired test The HD 10 will return to the pr...

Страница 12: ...an also activate a loopback in a downstream device An onboard 2047 pattern generator and error checker allow all 10 circuits of the HD 10 to be tested simultaneously The loopback test using the internal pattern generator is controlled via the faceplate DB 9 interface ISDN Loopback and BERT Testing Network loopback in the customer direction can be initiated from the DB 9 interface The 2047 pattern ...

Страница 13: ...vigate the menu as follows PERFORMANCE DSX PERFORMANCE The DSX Performance screen provides the following PM History in both the Near End and Far End Directions Errored Second and Severely Errored Second data 24 Hour and 15 Minute Registers To see the local Performance Monitoring of all 10 ISDN DSLs navigate through the menu as follows PERFORMANCE ISDN PERFORMANCE The ISDN Performance screen provid...

Страница 14: ...u t a t s L S D l a c i n a h c e M e z i S t h g i e W g n i t n u o M g n i t n u o m l a t n o z i r o h h g i h 8 3 1 x p e e d 2 1 0 1 x e d i w 2 1 5 z o 6 3 1 s b l 5 8 0 g n i s u o h e n o l a d n a t s r o f l e h s 0 1 D H s e d o C n o i t a r u g i f n o C C P e d o C r e w o P C T e d o C s n o i t a c i n u m m o c e l e T C I e d o C n o i t a l l a t s n I C T U O F N I X T U O X ...

Отзывы: