TROUBLESHOOTING HDSL2

This ADTRAN HDSL2 unit is equipped with troubleshooting-at-a-glance LEDs (identified on the reverse side of this document) 

that provide a simple means of identifying the location of certain faults. Additionally, screens available via the craft interface 

simplify the trouble isolation process. These screens and their associated benefits are described below.

Troubleshooting Screen

The Troubleshooting screen, available via the Main Menu, provides both current and 7-day historical view of performance. Errors 

and/or alarms detected at any of the monitored inputs (DSX-1, DS1 and HDSL) will be displayed in tabular format and highlighted 

in reverse video. This screen automatically escalates the error/alarm conditions using reverse video display. Faults detected and their 

associated meanings are as follows:

DSL:

LOS

Loss of HDSL sync

MARG

Margin has exceeded the alarm threshold

ATTEN

Attenuation has exceeded the alarm threshold

ERR

Errors recorded at the HDSL receiver

Facility:

GROUND Ground Fault Interrupt on span voltage (facility pair grounded)
SHORT

Short circuit (or low impedance) between facility pairs

OPEN

Open circuit between facility pairs

DSX-1/DS1:

LOS

Loss of signal (Red Alarm) at the DSX-1/DS1 receiver

CLK

T1 receive clock is out of range

RAI

Remote Alarm Indication (Yellow Alarm) detected at DSX-1/DS1 receiver

AIS

Alarm Indication Signal (Blue Alarm) detected at DSX-1/DS1 receiver

ERR

Errors recorded at DSX-1/DS1 receiver

Troubleshooting Guidance Screens

The Troubleshooting Guidance screens, available via the Troubleshooting screen, provide guidance on the fault(s) detected. The 

screens also provide the possible cause(s) and suggested corrective actions that can be taken.
Along with the Troubleshooting screens, the Detailed Status screen and Performance History screen, available via the craft access 

terminal, provide both real-time and historical view of this circuit.

FEATURES

TScan 2.0

This module incorporates the TScan 2.0

 feature. TScan allows for remote retrieval of circuit diagnostics and performs advanced 

fault location. For more information about TScan refer to the Installation and Maintenance practice.

Bad Splice Detection

The Runtime TScan splice detection feature is an ADTRAN proprietary non-intrusive method for detection of anomalies (bad 

splices) in the copper plant.
Data transmission transceivers, especially echo-cancelled technologies, such as HDSL2 (or HDSL4) are subject to degraded 

performance in the presence of bad splices. Poor splices in the cable are often undetected by normal testing methods. Often, these 

splices present no problem for the data transmission equipment until the point at which oxidation with the splice itself causes a rapid 

impedance change. Such a change in impedance may cause errors, signal margin fluctuation, and/or a retrain of the DSL 

transceivers. To address the difficulty in identifying bad splices, ADTRAN has developed the splice detection feature. This feature 

non-intrusively monitors the cable pair during runtime for the presence of bad splices, which may potentially impact service. 

Fault Bridging

Fault Bridging is a feature that minimizes downtime due to an intermittent impairment (GFI, short, micro-interruption, bad splice, 

noise burst, etc.) that appears on the cable pair. 
The bridging feature allows the DSL transceivers to maintain synchronization during such an interruption, thus avoiding a 25 to 30 

second retrain. Depending on the type of impairment, interruptions as long in duration as 200 ms can be bridged.

Fast Retrain

Fast Retrain is an ADTRAN proprietary feature that minimizes downtime due to an intermittent impairment (bad splice, noise burst, 

etc.) which due to its duration cannot be bridged.
When such impairments occur after HDSL synchronization has been achieved, the fast retrain feature will be invoked to restore 

service within 5 to 7 seconds. This short retrain time allows for reduced downtime compared to the traditional 25 to 30 second 

retrain duration.

NOTE: Fast-Retrain capable units must be installed on both ends of the HDSL2 circuit for this feature to function properly. Also, if there is a failure of a 

fast retrain attempt, for any reason, then the traditional (25-30 second) retrain will be initiated.

LOOPBACK AND CONTROL CODES

1 Units must be armed with 11000b or FF48h before this code can work.
2 This code will be detected only if the units are armed 

and

 there are no loopbacks active.

NOTE: All codes listed above must be sent for a minimum of five seconds in order to be detected and acted upon.
NOTE: If NIU is enabled, then the H2TU-R can be in network loopback when the H2TU-C loop-up codes are sent.

Function

Code (Hex / Bin)

Response

ARM (in-band)

a.k.a. 2-in-5 pattern

11000

When sent from the network, the units arm and the H2TU-R loops up, if NIU Loopback 

is enabled. When sent from the customer, the units arm.

ARM

(ESF Data Link)

FF48 or

1111 1111 0100 1000

sent via

Facility Data Link (FDL)

When sent from the network, the units arm and the H2TU-R  loops up, if NIU Loopback 

is enabled. When sent from the customer, the units arm.

Disarm (in-band)

a.k.a. 3-in-5 pattern

11100

When sent from the network or customer, all units are removed from the armed state and 

loopbacks are released

Disarm

(ESF Data Link)

FF24 or

1111 1111 0010 0100 

(FDL)

When sent from the network or customer, all units are removed from the armed state and 

loopbacks are released.

H2TU-C Network

Loopback

1

D3D3 or

1101 0011 1101 0011

If armed, the H2TU-C loops toward the network, 2 seconds of AIS (all 1s) is transmitted, 

the looped data is sent for 5 seconds, and a burst of 231 logic errors is injected. The burst 

of 231 logic errors continues every 20 seconds as long as the D3D3 pattern is detected. 

When the pattern is removed, the unit remains in loopback. If the pattern is re-instated, 

the injection of 231 logic errors continues every 20 seconds. If the pattern is sent from 

the network, the loop up and error injection is toward the network. If the pattern is sent 

from the customer, the loopback and error injection will be toward the customer

H2TU-R Customer

Loopback

1

3F02 or

0011 1111 0000 0010

When sent from the network, if the units are armed, the H2TU-R loops up data from the 

customer toward the customer

Loopdown

w/o disarm

9393 or

1001 0011 1001 0011

When sent from the network or customer, all units currently in loopback loop down. 

Armed units do not disarm. In order to behave like a smartjack, the H2TU-R does not 

loop down from a network loopback in response to the 9393 pattern if NIU Loopback is 

enabled. In order to behave like an NIU, the H2TU-R will not loop down from the net-

work side with 9393h.

Loopback Query

1

D5D5 or

1101 0101 1101 0101

This pattern allows a query of the devices to determine whether any units are in loop-

back. If D5D5 hex is received while in a loopback state, the unit in question transmits a 

logic error count. When sent from the network, logic errors are injected towards the net-

work to indicate a loopback is present toward the network as follows: 231 bit errors every 

20 seconds if an H2TU-C; 200 bit errors every 10 seconds if an H2TU-R. When sent 

from the customer, 200 bit errors will be injected toward the customer every 20 seconds 

if an H2TU-R is in customer loopback.

Loopback Time Out

Override

1, 2

D5D6 or

1101 0101 1101 0110

When sent from the network or customer, if the units are armed or a unit is currently in 

loopback, the loopback timeout override is disabled, and loopbacks do not time out 

(regardless of the current loopback timeout setting). As long as the units remain armed, 

the timeout remains disabled. When the units are disarmed, the loopback timeout reverts 

to the previous setting.

Span Power

Disable

1, 2

6767 or

0110 0111 0110 0111

When sent from the network or customer, if the units are armed, span power is disabled. 

When sent from the network, the span power is disabled as long as the pattern is detected. 

Once the pattern is no longer being received, the H2TU-C reactivates span power. All 

units then re-train and return to the disarmed and unlooped state. When sent from the 

customer, span power is only disabled momentarily.

Query Loop

Parameters

1

DBDB or

1101 1011 1101 1011

If the H2TU-C is in network loopback, errors are injected into the DSX-1 signal, and 

repeated every 20 seconds. The number of errors injected each time depends on the cur-

rent status of signal margin and pulse attenuation parameters on each loop. 111 errors are 

injected if all HDSL2 receiver points (H2TU-C, H2R, NET LP, H2R CST, and H2TU-R 

LP) indicate pulse attenuation is 



30 and signal margin is 



6 dB. 11 errors at a time are 

injected if any of the receiver points indicate pulse attenuation is > 30 dB and/or signal 

margin is < 6 dB.

H2TU-R Address 20

for extended 

demarc.

C754 or

1100 0111 0101 0100

If armed the H2TU-R loops up, 2 seconds of AIS (all 1s) is transmitted, the looped data is 

sent for 5 seconds, and then a burst of 200 logic errors is injected. The burst of 200 logic 

errors continues every 10 seconds as long as the C754 pattern is detected from network 

(20 seconds if from customer). When the pattern is removed, the unit remains in loop-

back. If the pattern is re-instated, the injection of 200 logic errors continues. If the pattern 

is sent from the network, the loopup and error injection is toward the network. If the pat-

tern is sent from the customer, the loopback and error injection is toward the customer.

HDSL2