Chapter 3. Test Modes
61200062L1-1
DSU 56/64 User Manual
3-9
REMOTE TESTS
The DSU 56/64 responds to three remotely activated tests.
•
Remote Digital Loopback (RDL)
•
CSU Loopback (LL)
•
DSU Loopback (RT)
The
RDL
test is initiated by a remote DSU and causes the local DSU
56/64 to loopback. The loopback point is the same as the loop only
point. See Figure 3-4 on page 3-6. This test is run to test the end-to-
end performance of the circuit.
Both the
CSU L
OOPBACK
and the
DSU L
OOPBACK
tests are
activated from the telephone company diagnostic test equipment
and are used to isolate trouble on a circuit.
The
CSU L
OOPBACK
, commonly called the
LL
test, has the same
loopback points as the
DTE
AND
L
OOP
test. It is used by the
telephone company to test the integrity of the local loop.
The
DSU L
OOPBACK
, commonly called the
RT
test, has the same
loopback point as the
L
OOP
O
NLY
test and is used by the telephone
company to test the operation of both the local loop and DTE
interface sections.
Содержание DSU 56/64
Страница 1: ...DSU 56 64 Data Service Unit User Manual Part Number 1200062L1 61200062L1 1E May 2001...
Страница 16: ...List of Figures xvi DSU 56 64 User Manual 61200062L1 1...
Страница 18: ...List of Tables xviii DSU 56 64 User Manual 61200062L1 1...
Страница 28: ...Chapter 2 Installation 2 6 DSU 56 64 User Manual 61200062L1 1...
Страница 38: ...Chapter 3 Test Modes 3 10 DSU 56 64 User Manual 61200062L1 1...