Chapter 3. Test Modes
3-4
DSU 56/64 User Manual
61200062L1-1
Figure 3-2. DTE with TP Test Diagram
The internal test pattern generator and detector of the DSU 56/64
operate with a 2047 data pattern. When this test is initiated, the test
pattern detector examines the receive data stream until
synchronization to the 2047 pattern occurs. Once synchronized, the
detector continues to check the receive data and reports any
detected bit errors by turning on the
E
RROR
LED.
Once a test is initialized with the internal test pattern generator and
detector, errors can be injected into the transmit data stream by
pressing
S
ELECT
and observed by watching the
E
RROR
LED turn
on for a brief period of time. As previously mentioned, the
DTE
WITH
TP
is automatically performed during the self-test sequence
for the DSU 56/64.
DTE AND LOOP TEST (LL)
This test is initiated at the local DSU 56/64 and allows independent
testing of the separate sections of the DSU 56/64. This includes
testing of the local DTE interface with data from the terminal or test
equipment and testing of the loop interface section of the local DSU
56/64 DSU
DTE
Receive
Interface
DTE
Transmit
Interface
Test
Pattern
Generator
Test
Pattern
Detector
Loop
Transmit
Interface
Loop
Receive
Interface
DTE
with
Test Pattern
TD
DTE or Test
Equipment
Interface
Network
Interface
RD
Loop TX
Loop RX
Содержание DSU 56/64
Страница 1: ...DSU 56 64 Data Service Unit User Manual Part Number 1200062L1 61200062L1 1E May 2001...
Страница 16: ...List of Figures xvi DSU 56 64 User Manual 61200062L1 1...
Страница 18: ...List of Tables xviii DSU 56 64 User Manual 61200062L1 1...
Страница 28: ...Chapter 2 Installation 2 6 DSU 56 64 User Manual 61200062L1 1...
Страница 38: ...Chapter 3 Test Modes 3 10 DSU 56 64 User Manual 61200062L1 1...