Chapter 3. Test Modes
61200062L1-1
DSU 56/64 User Manual
3-7
FAR END TESTS
Remote Digital
When the
RDL
test is initiated at the local DSU 56/64, it commands
the remote DSU into loopback with the industry standard V.54
loopback pattern. The loopback point and the signal paths for the
remote DSU are the same as the
L
OOP
O
NLY
test for a local DSU,
shown in Figure 3-4 on page 3-6. This Loopback
test is performed
with data from the terminal or test equipment. The RDL LED
flashes during initialization of the test and turns on solid once the
test is in progress.
To initiate the
RDL
test, perform the following steps:
1. Press
S
ELECT
five times to turn on the
RDL
test indicator.
2. Press
T
EST
while this test indicator is on.
3. To terminate this test, press
T
EST
.
RDL with Test Pattern (TP)
When the
RDL
WITH
TP
test is initiated at the local DSU 56/64, the
local DSU commands the remote DSU into loopback with the
industry standard V.54 loopback pattern. The loopback point and
the signal paths for the remote DSU are the same as the
L
OOP
O
NLY
test for a local DSU; see Figure 3-4 on page 3-6. This
L
OOPBACK
test
is performed with data from the internal test pattern generator and
error detector. The
RDL
and
PTRN
LEDs flash during initialization
of the test and turn on solid once the test is in progress.
To initiate the
RDL
WITH
TP
test, perform the following steps:
1. Press
S
ELECT
six times to turn on both the
RDL
and
PTRN
test
indicators.
2. Press
T
EST
while these test indicators are on.
3. To terminate this test, press the
T
EST
switch.
Содержание DSU 56/64
Страница 1: ...DSU 56 64 Data Service Unit User Manual Part Number 1200062L1 61200062L1 1E May 2001...
Страница 16: ...List of Figures xvi DSU 56 64 User Manual 61200062L1 1...
Страница 18: ...List of Tables xviii DSU 56 64 User Manual 61200062L1 1...
Страница 28: ...Chapter 2 Installation 2 6 DSU 56 64 User Manual 61200062L1 1...
Страница 38: ...Chapter 3 Test Modes 3 10 DSU 56 64 User Manual 61200062L1 1...