BCU LEDs

Indicator Color 

Description

AY 

Amber 

ON indicates a Yellow Alarm is being received from the T1 carrier facility

AR 

Red 

ON indicates the BR1/10 side is in a Red Alarm condition

TP 

Amber 

ON indicates Trunk Processing is active on all U-BRITEs (10)

RCV 

Red 

ON indicates a loss of framing of T1 signal from the T1 carrier facility

ESF 

Green 

ON indicates the T1 Extended SuperFrame format is selected

SF 

Green 

ON indicates the T1 SuperFrame format is selected

B8ZS 

Green 

ON indicates T1 B8ZS line coding is selected

AMI 

Green 

ON indicates T1 AMI line coding is selected

10DSL 

Green 

ON indicates D Channel 4:1 TDM mode is selected to transport 10 BRIs

8DSL 

Green 

ON indicates TR-397 3-DS0 framing across the T1 facility to transport 8 BRIs

EXT 

Green 

ON indicates External timing input is selected (BITS)

LOC 

Green 

ON indicates BR1/10 side is using a locally generated clock source to time the
T1 network

LOOP 

Green 

ON indicates BR1/10 clock is recovered clock from the T1 network

CAU 

Green 

ON indicates clock is recovered from the DSL position #1 to time the T1 network

DS1-LOC 

Green 

ON indicates the BR1/10 side is in a Local DS1 Loopback

RMT 

Green 

ON indicates the unit has initiated remote DS1 loopback when set in ESF mode
FLASHING indicates it responded to remotely commanded loopback, or has 
provided a loopback path for the T1 data-stream in SF mode

LP-SYNC*  Red 

ON indicates the U-interface is out of sync for the selected channel unit

LP-CRC* 

Red 

In normal operation flashes upon receiving NEBEs from the loop. In Local PM
mode flashes 6-19 CRCs and is solid when >20 CRC errors are detected from the
loop

CR-SYNC* Red 

ON indicates no TR-397 framing across the T1 carrier for the selected channel

CR-CRC* 

Red 

In normal operation flashes upon receiving NEBEs from the T1 carrier. In Local
PM mode flashes 6-19 CRCs and is solid when >20 CRC errors are detected
from the T1

DS0-LB* 

Amber 

ON indicates the selected U-BRITE is in a 2B+D commanded eoc loopback. 
Flashing once per second=B1 is looped, flashing twice per second=B2 is looped

ACT* 

Green 

ON indicates the customer’s NT1 has successfully exchanged ACT bits with the
network for the selected channel

* Status is for the channel unit selected on the DSL 10-position rotary switch on the LIU of the the
BR1/10 side

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s
order for use in the U.S. is ten (10) years.  For a complete faxback copy of ADTRAN’s 

U.S. and

Canada Carrier Networks Equipment Warranty

, call (877) 457-5007, Document #414.

PRICING AND AVAILABILITY 800.827.0807

TECH SUPPORT 800.726.8663

RETURN FOR REPAIR 256.963.8722

www.adtran.com

61150081L2-22A

BR1/10 2X MINI ISDN CHANNEL BANK

5

4

3

2

1

9

8

7

6

ADR3

ADR2

AD

R1

NT1

LPTX

LPBX

AD

R6
AD

R5

ADR4

10

CRTX

T
E
S
T

IN

M
O
N

OUT

LIU

1150079L2

ON

1    2    3   

4   

5    

6    

7   

8   

9   10

BCU

1                2               3                4

TEST

AY

      

TP

       

ESF

        

B8ZS

10DSL

EXT

LOOP

DS1-LOC

LP-SYNC

CR-SYNC

DSO-LB

AR

RCV

SF

AMI

BDSL

LOC

CAU

RMT

CRC

CRC

ACT

LB ON

REMOTE

DS0

B2

OFF
LOC
DS1
B1

1150080L1

Channel Selection

Loopback Address

DB-9 Connector

BCU DIP Test Switch

Recessed Test  Push  Button

Bantam Jacks

LOOPBACK TEST (ADR6, NT1)

Loopbacks in the network to customer direction can be initiated from either the ISDN switch (eoc) or
the BR1/10 LIU and BCU. The down-stream direction is automatically selected based on the channel
unit position in the circuit. To initiate a loopback, perform the following steps:

1

. Insert TX and RX bantam plugs of the DS0 digital test set (i.e. TPI 108/109) to the TEST jacks of the

LIU

2

. Connect test set clock interface to DB9 connector of the LIU and configure the test set for Near

Logic and 64kb/s

3

. Select the desired U-BRITE using the DSL rotary switch on the LIU( the selected U-BRITE LED

flashes red and green for 3 seconds

4

. Select the desired loopback address using the address rotary switch on the LIU (note: ADR1 is

always the U-BRITE your test set is connected to

5

. Select DS0 option and select the desired Bearer channel B1/B2 dip switches on the BCU

6

. Press the recessed TEST push-button on the BCU to initiate the loopback test

7

. The DS0 LB status LED on the BCU will illuminate if the loopback is successful and will not 

illuminate if the loopback failed

8

. Send and Receive 2047 to the established loopback and observe the DS0 digital test set for bit

errors

9

. It is not necessary to exit the test mode to select additional addresses (ADR2, NT1) or to change to

B1/B2 channels

10

. To terminate the loopback, press the TEST push-button and the amber DS0-LB LED will go out