Chapter 9. SNMP Management
9-6
ATLAS 800
PLUS
User Manual
61200226L1-1
Table 9-5 describes the Total Alert Traps, which describe events that have occurred
in the last 24-hour interval.
When one of the Total Alert thresholds is exceeded, the corresponding event bit is
set to 1 in the adDS1TotalAlert variable in the DS1 Alert Table. When enabled, the
ATLAS will send Alert Traps to each member of the Trap Destination List upon
detecting status bit changes in adDS1TotalAlert. If you have previously set the
corresponding enable bit = 1 in the adDS1TotalArm variable and
adDS1AlertEnable = On, then the ATLAS will send an Alarm Trap message. A
single Alert Trap message may report multiple event changes. The ATLAS clears
the event bits after sending the Trap message or sending the response to a Get
request for the adDS1TotalAlert variable.
The Current and Total Alerts described above are Near End events. The ATLAS
will also support Current and Total Alerts for the Far End. Far End Alert Traps are
generated upon status bit changes in adDS1FarCurrentAlert for Current Alerts
and adDS1FarTotalAlert for Total Alerts. Current and Total Far End Alerts can be
disabled by setting the corresponding enable bit = 0 in the adDS1FarCurrentArm
and adDS1FarTotalArm variables, respectively. Far End Alert Traps can also be
disabled by setting adDS1AlertEnable = Off.
Table 9-5. Total Alert Traps
Total Alert
Severity
Description
adATLAS800TotalES
WARNING
the total interval errored second threshold has been
exceeded
adATLAS800TotalSES
WARNING
the total interval severely errored second threshold
has been exceeded
adATLAS800TotalSEFS
WARNING
the total interval severely errored framing second
threshold has been exceeded
adATLAS800TotalUAS
MAJOR
the total interval unavailable second threshold has
been exceeded
adATLAS800TotalCSS
WARNING
the total interval controlled slip second threshold has
been exceeded
adATLAS800TotalPCV
WARNING
the total interval path code violation has been
exceeded
adATLAS800TotalLES
WARNING
the total interval line errored second threshold has
been exceeded
adATLAS800TotalLCV
WARNING
the total interval line code violation threshold has
been exceeded
Содержание ATLAS 800PLUS
Страница 1: ...ATLAS 800PLUS USER MANUAL Part Number 1200226L1 61200226L1 1A September 1998...
Страница 10: ...x ATLAS 800PLUS User Manual 61200226L1 1...
Страница 16: ...List of Figures xvi ATLAS 800PLUS User Manual 61200226L1 1...
Страница 18: ...List of Tables xviii ATLAS 800PLUS User Manual 61200226L1 1...
Страница 26: ...Chapter 1 Introduction 1 8 ATLAS_800PLUS User Manual 61200226L1 1...
Страница 52: ...Chapter 4 Front Panel Operation and Menu Structure 4 10 ATLAS_800PLUS User Manual 61200226L1 1...
Страница 96: ...Chapter 5 Using the Terminal Menu 5 44 ATLAS_ 800PLUS User Manual 61200226L1 1 DS0s Available Read security 5...
Страница 116: ...Chapter 7 Creating a Dial Plan 7 8 ATLAS 800 PLUS User Manual 61200226L1 1...
Страница 164: ...Index Index 12 ATLAS 800 PLUS User Manual 61200226L1 1A...
Страница 166: ......