2

Section 61222004L2-5, Issue 1

61222004L2-5A

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

The H2TU-C can be deployed in circuits consisting of
one H2TU-C and one H2TU-R.

System power and alarm bus connections are made
through the backplane of the STS 3192 shelf.  DSX-1
and HDSL2 signals are connected through the
wire-wrap pins or the 64-pin shelf connectors related
to each individual slot.

The H2TU-C contains an onboard fuse.  If the fuse
opens, it supplies a -48 VDC voltage to the fuse alarm
bus and all faceplate indicators turn 

off

.  The fuse is

not designed to be replaced in the field.

The H2TU-C uses a DC-to-DC converter to derive its
internal logic and span powering voltages from the
-48 VDC office supply.  Span powering voltages meet
all requirements of Class A2 voltages as specified by
Bellcore GR-1089-CORE.

Revision History

This is the initial release of this document.  Future
revisions to this document will be explained in this
section.

2. INSTALLATION

After unpacking the unit, inspect it for damage.  If
damage is noted, file a claim with the carrier, then
contact ADTRAN.  See 

Warranty and Customer Service

.

The H2TU-C plugs directly into standard CI Wescom
3192 office repeater shelves.  The unit may be
plugged into any of the first 28 slots of the 3192 shelf.
No installation wiring is required.

Faceplate Indicators

The H2TU-C has four faceplate LEDs which indicate
operational status.  

Table 1

 defines these LEDs.

Configuration is performed by manually selecting the
appropriate option switch or switches.  One
six-position  DIP switch (SW1) and one eight-position
rotary switch (SW5) are used to configure the mode of
operation.  Switch functions are detailed in 

Table 2

and

 Table 3

.  

Figure 2

 shows the location of these

switches.

Table 1.  Faceplate Indicators

1222004L2

Description

Indicates five possible states of the quality of the HDSL2 signals on the Loop:

Off ..................

No synchronization of H2TU-C and H2TU-R on the Loop

Red .................

Poor signal quality on the Loop (> 10

-7

 BER)

Yellow ............

Marginal signal quality on the Loop (

 2 dB margin above 10

-7

 BER)

Green .............

Good signal quality on the Loop (> 2 dB margin above 10

-7 

BER)

Blinking ..........

An error detected on either end of the Loop will cause this LED to blink briefly

Indicates the following three conditions:

Off ..................

Network-side DSX-1 signal is absent or is of a format that does not match the
provisioning of the HDSL2 circuit

Blinking ..........

Bipolar Violation (BPV), frame bit error (SF mode), or CRC error (ESF mode)
detected at DSX-1 signal

On Solid .........

Network-side DSX-1 signal is present and synchronized

Indicates the following three conditions:

Off ..................

No alarm condition detected

Red .................

Alarm condition detected either locally (H2TU-C), or locally and remotely
(H2TU-C and H2TU-R)

Yellow ............

Remote alarm condition detected

Indicates the following three conditions:

Off ..................

Unit is not in loopback or armed state

Yellow ............

Active loopback at the H2TU-C

Blinking ..........

Unit is armed but not in active loopback condition

Indicator

DSL .........

DSX .........

ALM ........

LBK .........

Содержание 3192 H2TU-C

Страница 1: ...Screen Loop Related 13 Figure 17 Performance Data Definitions Screen Path Related 13 Figure 18 Circuit ID Time Date Screen 14 Figure 19 Terminals Modes Screen 14 Figure 20 Alarm History Screen 15 Fig...

Страница 2: ...has four faceplate LEDs which indicate operational status Table 1 defines these LEDs Configuration is performed by manually selecting the appropriate option switch or switches One six position DIP sw...

Страница 3: ...to match the H2TU C 2 The ADTRAN H2TU R 1221026L6 supports AIS CI per the definition in ANSI T1 403 CORE 1997 The H2TU R will generate an AIS CI signal toward the network upon receiving unframed all o...

Страница 4: ...liance Codes Table 4 shows the Compliance Codes for the 3192 H2TU C The 3192 H2TU C complies with the requirements covered under UL 60950 Third Edition and is intended to be installed in an enclosure...

Страница 5: ...C D E F H J K L R1 RX DSX Out to DSX R TX DSX In from DSX GND 48V R HDSL2 Loop Fuse Alarm to Alarm Module T TX DSX In from DSX RCV LOS to Alarm Module T1 RX DSX Out to DSX Frame Ground T HDSL2 Loop T...

Страница 6: ...1 H2TU R H2TU C Loopbacks The H2TU C responds to two different loopback activation processes First loopbacks may be activated using the craft interface The Loopback Options Screen which provides for...

Страница 7: ...s mode enables all screen highlighting and cursor placement Print screen and log file commands are not available in this mode The default Terminal Mode is Real Time Update NOTE If you are using a pers...

Страница 8: ...erminal Once the speed has been determined an HDSL2 Main Menu is presented as illustrated in Figure 8 The Main Menu provides access to detailed performance and configuration information Selecting the...

Страница 9: ...address Figure 9 HDSL2 Unit Information Screen CIRCUIT ID 01 01 00 03 35 35 Press ESC to return to previous menu ADTRAN 901 Explorer Boulevard Huntsville Alabama 35806 2807 For Information or Technica...

Страница 10: ...dware setting The Span Status Screen illustrated in Figure 11 provides quick access to status information for each HDSL2 receiver in the circuit Figure 10 Provisioning Screen CIRCUIT ID 01 01 00 00 02...

Страница 11: ...nd H2TU R A Loop down ALL units command is available in lieu of the Self Test option when any loopback is active Figure 12 Detailed Status Screen CIRCUIT ID 01 01 00 00 05 18 Press ESC to return to pr...

Страница 12: ...24 Hour Performance History Path Data Screen CIRCUIT ID 01 01 00 00 06 35 Press ESC to return to previous menu Menu 24 Hour H2TUC DSX 1 Performance Data 1 Definitions ES P SES P UAS P CV P 2 Reset Da...

Страница 13: ...V EXZ 1544 or LOS 1 UAS L Unavailable Seconds 10 cont SES Ls CV L Code Violation Count BPV EXZ count NOTE Reverse video indicates invalid data due to a terminal restart or power cycle a data register...

Страница 14: ...pdating of HDSL2 circuit conditions and provisioning options as changes occur While in Real Time Update mode the unit is anticipating baud poll responses from the terminal CIRCUIT ID 01 01 00 00 40 53...

Страница 15: ...e most current circuit conditions and provisioning options The Alarm History Screen illustrated in Figure 20 provides the user with a detailed alarm history and events log for the HDSL2 and T1 spans T...

Страница 16: ...strated in Figure 21 provides a log history of HDSL2 circuit events The following is a summary list of possible events Circuit ID Change DS1 Transmit Level Option Change DSX DS1 Alarm Type Active Inac...

Страница 17: ...2 45 2 629 19 PIC 1 551 1 587 1 634 19 Pulp 1 817 1 856 1 909 Table 7 Loop Insertion Loss Data Frequency Hz Maximum Loss dB 3 000 12 0 10 000 15 0 50 000 25 5 100 000 30 0 150 000 32 75 200 000 35 25...

Страница 18: ...ve unit to ADTRAN See Warranty and Customer Service section of this Practice 9 PRODUCT SPECIFICATIONS Product specifications are detailed in Table 9 10 WARRANTY AND CUSTOMER SERVICE ADTRAN will replac...

Страница 19: ...7 399 feet ABAM 400 533 feet ABAM 534 655 feet ABAM DSX 1 Line Code AMI B8ZS DSX 1 Format SF ESF Unframed Power Tested with the ADTRAN H2R P N 1221045L1 and the ADTRAN H2TU R 1222026L6 Total Power wor...

Страница 20: ...20 Section 61222004L2 5 Issue 1 61222004L2 5A...

Страница 21: ...he DSX 1 signal toward the network Appendix A HDSL2 Loopbacks H2TU R Loopback A regenerative loopback of the DS1 signal toward the network This loopback is in addition to a separate Smartjack loopback...

Страница 22: ...isarmed State is the normal mode of operation Each HDSL2 element is transparent to the data flow However the in band data flow and the ESF data link are monitored for the arming sequence The in band c...

Страница 23: ...to exceed 16 repetitions to allow detection and loop down of up Table A 1 HDSL2 Loopback Control Codes Name Arming In band Arming ESF Activation H2TU C Activation H2TU R Deactivation all HDSL2 element...

Страница 24: ...DS1 signal However the data flow is monitored for the in band deactivation sequence the in band disarming sequence and the ESF data link disarming sequence Also a loop up time out value causes automat...

Отзывы: