61222004L2-5A
Section 61222004L2-5, Issue 1
13
Figure 16
and
Figure 17
display the Performance
Data Definitions Screens.
Figure 16. Performance Data Definitions Screen, Loop Related
Figure 17. Performance Data Definitions Screen, Path Related
CIRCUIT ID: 01/01/00 03:38:08
Performance Data Definitions
H2TUC, H2TUR, and H2R LOOP Related: HDSL2 Framing
ES-L Errored Seconds CRC>=1 or LOSW>=1
SES-L Severely Errored Seconds CRC>=50 or LOSW>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls
DS1 and DSX-1 Line Related: Superframe and Extended Superframe
ES-L Errored Seconds (BPV+EXZ)>=1 or LOS>= 1
SES-L Severely Errored Seconds (BPV+EXZ)>=1544 or LOS>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls
CV-L Code Violation Count (BPV+EXZ) count
NOTE: Reverse video indicates invalid data due to a terminal restart (or power
cycle), a data register reset, or a system date or time change.
N. Next
P. Previous Selection:
CIRCUIT ID: 01/01/00 03:38:27
Performance Data Definitions
DS1 and DSX-1 Path Related: Superframe Extended Superframe
ES-P Errored Seconds FE>=1 or CRC>=1 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
SES-P Severely Errored Seconds FE>=8 or CRC>=320 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
UAS-P Unavailable Seconds >10 cont. SES-Ps >10 cont. SES-Ps
CV-P Code Violation Count FE count CRC error count
NOTE: Under a UAS-P condition, ES-P and SES-P counts are inhibited.
Under a SES-L or SES-P condition, the respective CV-L or CV-P count is
inhibited.
P. Previous Selection:
Содержание 3192 H2TU-C