background image

4

61287802F1-13F

2. Route the fiber in the fiber tray and terminate it at the 

bulkhead connector.

3. Connect a fiber jumper from the bulkhead connector to the 

SC/APC connector at the bottom of the ONT (refer to 

Figure 

7

).

Figure 7. Fiber jumper to the ONT

4. Route the fiber jumper so that when the ONT is closed, the 

fiber is not pinched.

Connect Power/Alarm

f

     

WARNING!

Before making any power connections to this equipment, verify the 
power is off (fuse removed/breaker tripped). This equipment should 
only be operated from the type of certified/listed power supply 
supplied by the manufacturer with the equipment.

The ONT is supplied with a 7-pin Power/Alarm Connector. Refer to 
the following steps and the two figures below to connect Power/
Alarms to the ONT.

1. Remove the Power/Alarm Connector (shown i

Figure 8

from 

the accessory bag.

Figure 8. Power/Alarm Connector

2. Route the Power/Alarm wire through the port as shown in 

Figure 9

.

234567

1

Power/Alarm Connector

Pin 1

Pin 7

Figure 9. Power/Alarm Connection and Routing

3. Terminate the 2 power leads (Pins 6 and 7), and the five 

Uninterruptible Power Supply (UPS) leads (see the pinout 
table).

4. Connect the Power/Alarm connector to the bottom of the ONT 

(refer to 

Figure 8

).

5. Tie wrap and route these wires as shown in 

Figure 10

. This 

will prevent the connector from coming loose when the ONT is 
closed.

Figure 10. Power/Alarm Connector Installed

The following table provides a pinout of the Power/Alarm connector.

Install a Local Power Source

f

     

WARNING!

The ONT must be powered by a UL Listed Power Supply suitable 
for the application (rated 12 VDC, 1.25 A minimum) with an LPS 
output. Installation of the Local Power Source will be dictated by on-
site conditions and local telephone company practices.

PIN

Description

1

Low Battery 

2

Battery Missing 

3

Replace Battery 

4

On Battery 

5

Signal Return 

6

12 V Return 

7

+12 VDC 

Fiber Connection

Ground Connection

Power Connection

7

S

O

R

B

L

1

+

6 5 4 3 2 1

Tie Wrap Wires as shown

Note:
Even though there are brackets
to position the Power / Alarm
Connector wires, their use is

not

 recommended. Use of

these brackets can “bind” the 
wires when the ONT is closed.

Power / Alarm Connector

ule

Содержание 1287802F1

Страница 1: ...SS 1 LASER PRODUCT INSTALLATION This section explains how to install the NID ground the NID route and attach the incoming Fiber and install the ONT in the NID There is also a section on connecting POTS and Ethernet services After unpacking the ONT inspect it for damage If damage is noted file a claim with the carrier and then contact ADTRAN For more information refer to the warranty f WARNING Read...

Страница 2: ...data the connection to the ONT is through the RJ 45 Ethernet connector For POTS the connection is made through 2 4 Two screw Terminal Bridges 2 for the 452 and 4 for the 454 or RJ 11 connections Installation Steps To install the ONT complete the following steps Mount the NID Enclosure Ground the NID Install the ONT Route the Fiber Connection Connect Power Alarm Install a Local Power Source Install...

Страница 3: ...Splice SC APC Bulkhead NID P N 1187770G1 g NOTE Clean all optical surfaces before connecting cables OptiTap NID P N 1187771G1 To install the fiber connection using the Optical Connector refer to Figure 5 and complete the following steps Figure 5 Optical Connector 1 Route the incoming fiber cable through the port identified in Figure 1 2 Connect the optical connector 3 Connect a fiber jumper from t...

Страница 4: ... 9 Power Alarm Connection and Routing 3 Terminate the 2 power leads Pins 6 and 7 and the five Uninterruptible Power Supply UPS leads see the pinout table 4 Connect the Power Alarm connector to the bottom of the ONT refer to Figure 8 5 Tie wrap and route these wires as shown in Figure 10 This will prevent the connector from coming loose when the ONT is closed Figure 10 Power Alarm Connector Install...

Страница 5: ...in any other fashion may cause harmful interference to radio communications ans is in violation of the FCC Rules part 15 CLEI TEL NUMBER PWR GPON POTS1 POTS2 POTS3 POTS4 Ethernet Connections POTS Connections Two Post Bridge Cable Routing Area POTS and Ethernet Port Captive Screw 2 Trim each wire to length 3 Connect the tip and ring wires to the terminal bridges 4 Insert the RJ 11 connectors from t...

Страница 6: ...r dial tone and flashes the GPON LED green for approximately 10 seconds with a cadence of 300 milliseconds on off before it continues its startup ranging process g NOTE If a failure occurs the ONT plays reorder tone and displays Invalid on the caller id display If the pattern is entered incorrectly the caller id displays Re enter if the first ID does not match the second Entering an invalid Regist...

Отзывы: