Safety and Regulatory Compliance
61287722G1-5B
5
WARNING
!
The
10/100/1000
Base
‐
T
port(s),
POTS
port(s)
and
DS1
port(s)
are
classified
as
Type
4
as
defined
in
Appendix
B
of
GR
‐
1089
‐
CORE
Issue
5,
and
are
suitable
for
connection
to
intra
‐
building
or
unexposed
wiring
or
cabling
only.
Do
not
metallically
connect
these
ports
to
interfaces
which
connect
to
the
Outside
Plant
(OSP)
or
to
the
OSP
wiring.
The
10/100/1000Base
‐
T
ports
and
POTS
are
designed
for
use
as
an
intra
‐
building
unexposed
interface
only
(Type
4
ports
as
described
in
GR
‐
1089
‐
CORE
Issue
5)
and
require
isolation
from
exposed
OSP
cabling.
The
addition
of
Primary
Protectors
is
not
sufficient
protection
in
order
to
connect
this
interface
metallically
to
OSP
wiring.
NOTE
•
The
Total
Access
372
SBU
ONT
is
designed
to
be
deployed
in
GR
‐
3108
‐
CORE
environmental
class
4
as
defined
in
GR
‐
3108
‐
CORE
issue
2.
•
Power
supply
input
and
output
conductors
of
equipment,
and
signal
conductors
of
equipment
which
are
exposed
outside
of
the
building,
are
intended
to
be
less
that
140
feet
(42.6
meters)
and
have
adequate
clearance
from
power
and
lightning
conductors
in
accordance
with
NEC
725
and
800.
Final
acceptance
of
the
Listed
equipment
installation
will
ultimately
be
up
to
the
local
Authority
Having
Jurisdiction
(AHJ).
This
product
is
designed
to
meet
the
following
environmental
classes:
• ETSI
EN
300
019
‐
1
‐
1
“Classification
of
environmental
conditions;
Storage”,
Class
1.2
• ETSI
EN
300
019
‐
1
‐
2
“Classification
of
environmental
conditions,
Transportation”,
Class
2.3
• ETSI
EN
300
019
‐
1
‐
4
“Classification
of
environmental
conditions,
Stationary
use
at
non
‐
weatherprotected
locations”,
Class
4.2H
The
equipment
is
designed
to
function
without
degradation
during
exposure
to
all
test
sever
‐
ities
per
Class
4.2H
of
ETSI
EN
300
019
‐
1
‐
4.
This
product
complies
with
ETSI
EN
300
386
“Electromagnetic
compatibility
and
Radio
spectrum
Matters
(ERM);
Telecommunication
network
equipment;
Electromagnetic
Compati
‐
bility
(EMC)
requirements.”
This
product
meets
EU
RoHS
Directive
2002/95/EC
and/or
applicable
exemptions.
Refer
to
www.adtran.com
for
further
information
on
RoHS/WEEE.
Содержание 1287722G1
Страница 6: ...Total Access 372 Small Business Unit ONT Installation and Maintenance Guide vi 61287722G1 5B ...
Страница 10: ...Total Access 372 Small Business Unit ONT Installation and Maintenance Guide x 61287722G1 5B ...
Страница 12: ...Total Access 372 Small Business Unit ONT Installation and Maintenance Guide xi 61287722G1 5B ...