Chapter 7. Network Port Configuration
7-6
DSU IQ User Manual
61200212L1-1
Max PVC Count
Sets the maximum number of PVCs that the DSU IQ will monitor
for statistical information. This value determines the amount of
history intervals available for storage. To get the maximum
amount of statistical history storage, set this value equal to the
number of PVCs assigned to the frame relay port. A smaller value
increases history interval count but puts some of the PVC statistics
into the unknown category.
History Interval Count (HST INT COUNT)
Sets the number of history intervals to store for statistics. History
intervals are displayed in the View by Interval portions of the
Statistics menus. These views provide data divided into columns
grouped by the interval of time selected in the History Interval Size
field (see System Configuration on page 9-1 for more information).
The History Interval Count field determines how many intervals
can be stored at a time. The maximum value allowed is affected by
the previously mentioned PVC Count selection.
PVC Options (PVC CONFIG)
The information in this menu must be entered for each PVC. DLCI
numbers and their corresponding CIRs are provided by the service
provider.
DLCI
Enter the Network DLCI. Range is
16
to
1007
.
When configuring PVC options using the front panel the
N
EXT
,
P
REV
,
A
DD
, and
D
ELETE
keys are used. See Operation on page 3-1 for more
information on front panel operation.
Содержание 1200212L1
Страница 12: ...xii...
Страница 28: ...List of Tables xxviii DSU IQ User Manual 61200212L1 1...
Страница 40: ...Chapter 2 Installation 2 6 DSU IQ User Manual 61200212L1 1...
Страница 70: ...Chapter 4 Applications 4 14 DSU IQ User Manual 61200212L1 1...
Страница 90: ...Chapter 7 Network Port Configuration 7 10 DSU IQ User Manual 61200212L1 1...
Страница 136: ...Chapter 10 Statistics 10 32 DSU IQ User Manual 61200212L1 1...
Страница 154: ...Appendix B Specifications B 4 DSU IQ User Manual 61200212L1 1...
Страница 172: ......