Chapter 7. Network Port Configuration
7-4
DSU IQ User Manual
61200212L1-1
Frame Relay Options (FR OPT)
The terminal screen in Figure 7-3 appears when you select
F
RAME
R
ELAY
O
PTIONS
from the network configuration menu.
Figure 7-3. Terminal Network Port Frame Relay Options Menu
Signal Type (SIGNAL)
Set the signaling type option to match the network signaling type.
Choices are
N
ONE
,
LMI
(gang of four),
ANSI T1.617-D
(Annex D),
ITU-T Q.933-A
(Annex A), or
A
UTO
.
A
UTO
mode forces the DSU IQ
to use the same signaling type as the attached frame relay DTE. If
A
UTO
is selected and there is no DTE device attached, the DSU IQ
uses
ANSI T1.617-D
signaling type.
T391
Set the time (in seconds) between polls to the frame relay network.
N391
Determine how many link integrity polls occur in between full
status polls.