61200060L1-1
TSU User Manual
4-1
Chapter 4
Testing Example
Prior to actually using the TSU to pass data, it is
recommended to run tests on the circuit.
The testing consists of sending a test pattern from end to end
and checking for errors in the pattern. There are two types of
tests used to accomplish this.
•
Send the pattern from one end and loopback the far end.
•
Send the pattern from both ends and check at both ends.
Far End Looped Back Test
Two types of tests can be executed with the far end looped.
The first is a check of the network and the network interfaces
at both ends (511). The second is a check of the DTE port.
Network Interface Test
The Network Interface Test can be run with any channel
setup because the 511 pattern is always sent in the occupied
channels.
1.
At the main menu, use the scroll keys to place the cursor
on
4)TEST
.
2.
Press
ENTER
to select.
The first two test submenu items display.
1 ) M O N I T O R 3 ) U T I L
2 ) C O N F I G 4 ) T E S T
Содержание 1200060L1
Страница 1: ...TSU T1 FT1 Data Channel Service Unit Part Number 1200060L1 User Manual 61200060L1 1B September 1999...
Страница 8: ...viii...
Страница 12: ...Table of Contents xii TSU User Manual 61200060L1 1...
Страница 14: ...List of Figures xiv TSU User Manual 61200060L1 1...
Страница 16: ...List of Tables xvi TSU User Manual 61200060L1 1...
Страница 66: ...Chapter 3 Operation 3 30 TSU User Manual 61200060L1 1...
Страница 70: ...Chapter 4 Testing Example 4 4 TSU User Manual 61200060L1 1...
Страница 72: ...Appendix A TSU Complete Menu A 2 TSU User Manual 61200060L1 1...
Страница 74: ...Appendix B DTE Data Rate Chart B 2 TSU User Manual 61200060L1 1...
Страница 78: ......