Total Access 362R Single Family Unit with RF Return Installation and Maintenance Guide
32
61187715G1-5B
SC/APC Fiber Drop Cable Installation
A
fiber
connection
is
required
between
the
inner
ONT
enclosure
and
the
fiber
termination
point
in
the
Outer
Enclosure.
This
may
be
achieved
by
using
the
provided
fiber
patch
cord.
To
install
the
fiber
connection,
perform
the
following
steps:
Remove
the
dust
cover
from
one
end
of
the
fiber
patch
cord
and
attach
it
to
the
incoming
fiber
drop
cable
at
the
SC/APC
bulk
head
(see
).
1. Connect
the
fiber
cable
coming
into
the
Splice
Housing
to
the
SC/APC
Connector.
2. Route
the
fiber
patch
cord
from
the
SC/APC
connector
to
the
connection
on
the
bottom
of
the
Electronics
Module
as
shown
in
.
Ensure
that
this
cable
is
not
pinched
when
the
Electronics
Module
is
closed.
3. Close
the
Electronics
Module
and
secure
by
tightening
the
“Inner
Security
Screw”
(see
19).
Figure 19. SC/APC Fiber Installation
CAUTION
!
Position
the
SC/APC
fiber
optic
cable
so
that
it
does
not
become
crimped
when
the
Electronics
Module
is
closed.
SC
/
APC Connector on
bac
k
of Electronics Module
+ 12VDC
12V R
T
N
SIG R
T
N
ON BA
T
REP
BA
T
BA
T
MIS
LOW BA
T
7
6
5
4
3
2
1
SC
/
APC Connector in
Splice Housing Bul
k
head