ST-LC OPERATION MANUAL(EN) 2011-04-27
22 / 35
A2
−
15
Pcode
0000
100
0
9
999
Pcode
(P.CodE): Pass Code
;
Please remind and write down the new pass
code so that access to programming level.
Settable range: 0000~9999
Shift
Up
Down
Enter
A2
−
16
Flock
none
none
all
Flock
(F.LoCK): Function Lock)
;
There are 4 levels programmable for lock
that the function is to avoid miss-setting.
Programming:
none
(None):
no lock at all. User can
access to user level for
checking and setting.
user
(User Level):
User level lock.
User can access to user level
for checking, but can not
setting.
eng
(Programming Level):
Programming level lock. User
can access to programming
level for checking, but can not
setting.
all
(All Level):
All lock. User can
access to all level for checking,
but can not setting.
Up
Down
Enter
RELAY GROUP
(The group will not be displayed except the relay function is to be specified)
INDEX
FUNCTION DESCRIPTION
PARAMETERS & SETTING
SET
relay
group
RELAY GROUP INDEX PAGE
In following pages,press
for 1 second to back RELAY GROUP INDEX PAGE
B
−
1
rYsb
)0
00)
0
9
9(9
rYsb
(rY.Sb): Start band of Relay Output
After PV surpasses start band, when again
after start delay time, the relay will only then
start the PV and the setting value does quite
outputs.
Start Delay
Fig.2
Start D ela y Tim e
St art B and
H i Se tting
R elay
Energized
ON
Inhibit
Inhibit
[
rYsb
]
[
ry_.sp
]
[
r Ysd
]
c
d
Settable range: 0~9999 counts
Shift
Up
Down
Enter
B
−
2
rYsd
)0)0
)0)
0
(
5(9
rYsd
(rY.Sd): Relay Output start delay
time
Settable range:
0:00.0~9(M):59.9(S)
Shift
Up
Down
Enter
Next Page