ADT TSSC-BASE Скачать руководство пользователя страница 5

– 5 – 

CHIME MODE 

Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME 

mode. When activated, three tones sound at the Keypad whenever a protected perimeter door or window is 

opened, and the “Not Ready” message is displayed. Pressing the 

READY

 [*] key displays the open protection 

points. 
Note that Chime mode can be activated only when the system is disarmed. 

1. 

To turn Chime Mode on,

 enter the security code and press the 

CHIME

 key [9]. 

2. 

To turn Chime Mode off,

 enter the security code and press the 

CHIME

 key again. 

KEYPAD TONES 

When the Keypad is generating a periodic beep (once per minute), pressing the [*] key provides more 

information. 
When the system is armed and there is a trouble condition, the Keypad displays “Device Trouble”.  Pressing 

the [*] key provides more information. 

 

QUICK EXIT 

To start Quick Exit when enabled. 
Stay Mode – Enter User code + STAY key. 
Instant Mode – Enter User code + INSTANT key  
Night-Stay Mode – With the system armed in Night-Stay Mode and the exit delay expired,  
enter User code + STAY key + STAY key. 

 

HOST CHECK-IN 

If Host Check-In interval is set to 200 seconds, “Download Com/Upload Completed” message is displayed at 

the Keypad every 200 seconds.  

 

TEST MODE 

Use Test mode to check each protection point for proper operation.  
Testing should be conducted weekly to ensure proper operation. 

1.  Disarm the system and close all protected windows, doors, etc.  
2.  Enter the Master code + [5] (TEST), then press 1. 
3.  Listen. The external sounder should sound for about 1 second then turn off.  
4.  Fault all zones in turn and listen for three beeps from the keypad. ID of each faulted point should appear 

on the keypad display. The display clears when the zone is closed. Note that if wireless motion detectors 

are used, there is a 3-minute delay between activations. This conserves battery life. 

5.  Test all smoke and CO detectors following the manufacturer's instructions and check the display. 
6.  When all zones have been checked and are intact (closed), there should be no zone identification 

numbers displayed on the keypad. 

7.  Exit test mode: security code + [1] (OFF). 

 

NOTES: 

  The keypad sounds a single beep about every 60 seconds as a reminder that the system is in the Test 

mode. 

  Alarm messages are not sent to your Central Station while Test mode is on. 

  If a problem is experienced with any protection point (no confirming sounds, no display), call for service 

immediately. 

  If the test mode is inadvertently left active, it automatically turns off after 30 minutes. During the final 

five minutes, the keypad will emit a double beep every 30 seconds. 

Содержание TSSC-BASE

Страница 1: ...e 1 Low Battery Missing Battery Charging Battery Normal In Programming Red STATUS Not Ready to Arm Armed System Trouble Ready to Arm Device Trouble Can Arm Device Trouble Cannot Arm Alarm Alarm Memory...

Страница 2: ...d Amber Green Flashing Green Flashing Amber Flashing Red Alternating Flashing POWER Low Battery Missing Battery when no AC Keypad s battery Charging AC On Battery Normal no AC Low Battery no AC Keypad...

Страница 3: ...ogrammed TEST Keypad only Tests the system and alarm sounder if disarmed BYPASS Keypad only Removes individual protection zones from being monitored by the system Displays previously bypassed protecti...

Страница 4: ...they do not need to know e g bypassing protection zones Enter Master code CODE key 8 2 two digit user no 4 digit new user s code User numbers 02 through 96 are available with various authority levels...

Страница 5: ...every 200 seconds TEST MODE Use Test mode to check each protection point for proper operation Testing should be conducted weekly to ensure proper operation 1 Disarm the system and close all protected...

Страница 6: ...acing the battery and reattaching the Keypad to the mounting plate enter the 4 digit security code OFF sequence twice to clear any trouble condition REPLACING THE BATTERY IN A DESK MOUNTED KEYPAD 1 Pl...

Страница 7: ...ubject to compromise by sophisticated intruders Even if the system responds to the emergency as intended however occupants may have insufficient time to protect themselves from the emergency situation...

Страница 8: ...o a period of 90 days from the date of completion of installation The exclusive remedy of the customer hereunder shall be repair or replacement as stated above Under no circumstances shall ADT be liab...

Отзывы: