The TEST mode commands the control station to beep continuously and light the
corresponding zone indicator, each time a zone is violated. The zone indicator of

each tested zone will remain lighted while each succeeding zone is tested. Testing
can be performed only while the system is disarmed. Testing the system should be
performed in both ELECTRICAL 

 AC ON and STANDBY BATTERY

modes. Your neighbors’ understanding and cooperation is very important. When
you are away from your residence (or commercial 

 play an

important role. Advise them that you have a security system and ask them to notify

the proper authorities if your system is sounding. The burglar alarm typically has

a pulsing bell and a fire alarm has a steady horn sound. If the battery fuse lead is
opened, call your security representative for service.

Note: A 

lighted zone indicator means 

 at least one sensor of  that

particular zone 

 been tested. It does not 

 mean that 

sensors of that zone were tested.   is recommended that you test your
system on 8 weekly 

1.

2.

3.

8.

9.

The system must be disarmed.

Use the zone I.D. card to determine the area of protection which corresponds to
each zone.
To simplify testing, all zones should first be secured (READY light ON). If it
is not possible to secure all zones prior to beginning the walk test mode, please
note that the control station will beep continuously as a result of the non-secure

zones. This will eliminate the advantages of the audible walk test mode,
although the zone indicator lights may still be relied upon for testing.
Press key 8 and hold for three seconds. The control station will beep three times

to signify entry into the TEST mode.
Violate a detection zone (open a door, window, etc.). The control station will

beep continuously and the indicator of the corresponding zone will light.

Secure the zone (close the door, window, etc.). The control station beeping will
cease.

The interior detection devices will also cause the control station to beep if

entering those protected areas when testing unless the INTERIOR is first turned

OFF. You may also want to walk test motion detection devices to check whether

the pattern is covering the areas of concern.
Begin at step five to test the remaining sensors.

Press the   *  key when finished testing.

 Your 

 should be 

 tested at 

 

 par 

 to

insure proper operation. 

 your 

 representative for 

plate instructions on regular system 

 and testing 

 the wall mounted transformer which powers the system Is 

moved for any reason, test the system to see If the standby 

 Is

adequately powertng 

 

 the transformer, secure to

the 

 with the restraining 

 

 screw, 

 test the system

 to 

 It   

 AC power.

11

Содержание Safewatch Plus Enterpreneur Security Systems

Страница 1: ......

Страница 2: ......

Страница 3: ...False Alarms 6 THE EMERGENCY KEYPAD PANIC ALARMS 7 Emergency Alarm Activation 7 Resetting The Emergency Alarm 7 SPECIAL FEATURES 8 Chime Mode 8 Force Arming 8 Bypassing Zones 9 Key Switch Operation 10 Access 10 The Reset Key 10 Remote Programming 10 Audible Zone Testing 11 FIRE DETECTION 12 What To Do If The Fire Alarm Sounds 12 Fire Supervlsoryflrouble Resetting Smoke Detectors 12 Emergency Evacu...

Страница 4: ...Depending upon the I installation this card pulls 1 out from the left or right I Armed Status If lighted the system is armed condition exists Contact your security representative side of the control station Trouble Indicator f ighted a trouble Alarm Co Police Fire If not lighted the system is disarmed If b inking time is being provided to exit the building after which the system will be armed Alar...

Страница 5: ... an exit delay time which allows a specific amount of time to leave through any delay defined intrusion detection zone without causing an alarm Be sure that you have been informed on routes to enter and exit from without causing an alarm If too much time is taken to exit the beeping tone will change to a steady tone indicating the start of entry delay Disarm the control and start over to avoid a f...

Страница 6: ...elay may also be programmed to automatically turn off at this time When the system is disarmed the interior and delaywilI return to their normal on or off state See your security representative for details Q Two Digit Arming Your system may have been programmed with an abbreviated arming feature When this feature is enabled only the first two digits of your User Code will be required to arm the sy...

Страница 7: ...rm has occurred Leave the premises immediately and go to the nearest phone to contact the appropriate authorities Do not procede into the premises 2 Enter your User Code 3 The red armed light should turn off indicating that the system is disarmed Testing the Burglar and Fire Alarm Audibles UL listed burglar and fire alarm systems which have separate audible sounding devices require a weekly test N...

Страница 8: ...tifying the specific area that was violated Use the zone I D card to determine the area of protection which corresponds to each zone If the alarm was activated manually by pressing one of the emergency keys no zone indicators will be lighted Press the key to extinguish the ALARM indicator after determining the type of alarm that occurred and area of protection involved A history of the alarm condi...

Страница 9: ...a specific type of alarm as programmed and labeled by your installer To activate an Emergency Alarm 1 Press the appropriate emergency panic key The Emergency Alarm will activate NOTE Your lnstalter may have progmmmed the panic zones to ignore momentaty key presses and to activate only by pressing and holding pressed for three seconds or pressing at least twice within three sec onds Checkwlthyoutse...

Страница 10: ... The control station will now beep two times when any burglar zone is opened Note The CHIME feature does not annunciate lntertor zones To Turn The CHIME Off Press the 6 key and hold for three seconds The control station will beep two times to signify that the CHIME has been turned off Your system may be programmed for quick arming even with one or more zones faulted In this condition when an attem...

Страница 11: ...em must be disarmed Press the BYPASS key then enter the number of the zone l 6 to be bypassed The corresponding ZONE indicators l 6 will blink to indicate zones that have been bypassed The blinking will cease 30 seconds after the system is armed and the exit delay expires Repeat steps 2 and 3 to bypass other zones To Cancel A Zone Bypass The system must be disarmed Press the BYPASS key followed by...

Страница 12: ...e ACCESS feature the control station can be used to switch other devices on and off or as a timed switch This feature is most commonly used to activate an electric door release or switch lights on and off Consult your security representative for more information The key may be used to D Silence the control station sounder and the audible output during Auxiliary A Fire and Auxiliary C Emergency ala...

Страница 13: ... fully understand thlsopwatlon USER CODES Your system may be programmed to accept up to five regular User Codes and one Muster User Code Each code may be comprised of any four digit sequence Do not program 1234 or 1111 as User Codes Codes may be added deleted or changed as necessary The Master User Code code 1 performs all of the User Code functions plus allows access to the programming mode User ...

Страница 14: ...ress 1 then to change the Master User Code or 4 then to program User Code 4 etc The control station will beep three times to signify acceptance Enter the desired new 4 digit code sequence After the fourth digit is entered the control station will emit one short beep followed by one long beep then the system will exit the programming mode automatically To program another code return to step 2 1 2 3...

Страница 15: ... see note Press key 6 then to instruct the control that you wish to program the desired code sequence for User Code 6 The control station will beep three times Enter the desired four digit code sequence After the fourth digit is entered the control station will emit one short beep followed by one long beep then the system will exit the programming mode automatically Repeat step 2 to re enter the p...

Страница 16: ...Notes ...

Страница 17: ...ior to beginning the walk test mode please note that the control station will beep continuously as a result of the non secure zones This will eliminate the advantages of the audible walk test mode although the zone indicator lights may still be relied upon for testing Press key 8 and hold for three seconds The control station will beep three times to signify entry into the TEST mode Violate a dete...

Страница 18: ... the alarm monitoring service or the proper authorities immediately if the alarm was unintentional The red ALARM light will remain on To clear the alarm enter a valid User Code If the TROUBLE indicator lights a Fire Supervisory Trouble condition may exist Consult your Security Representative to define the trouble condition Many smoke detectors latch on and illuminate a built in indicator when trig...

Страница 19: ...mergency escape ladders for rooms above the first floor Check the ladders to be sure that they will reach the ground Draw a rough sketch of your escape plan so that everyone is familiar with it Practice your escape plan to assure that everyone knows what they have to do in an emergency situation 6 Establish a meeting place outside where your family is to report 7 Advise the local fire authority if...

Страница 20: ...m ofthedoorwithyourhipagainstthemiddle andonehandagainstthetopedge Open slightly If there is arush of hot air slam the door quickly and latch it Unvented fire will build up considerable pressure Be sure that all the household realizes this danger Use your neighbors phone or street fire alarm box The job of extinguishing the fire should be left to the professionals Too many unforeseen things can oc...

Страница 21: ...e lower level Ceiling mounted smoke alarms should be located in the center of the room or hall not less than 4 inches from any wall When the detector is mounted on a wall the top of the detector should be 4 to 12 inches from the ceiling Do not install smoke alarms where normal ambient temperatures are above lOOoF 37 8 C or below 40 F 4 C Also do not locate smoke detectors in front of air condition...

Страница 22: ...ote or A Smoke Detector should be located on each story A Smoke Detector should be located between the sleeping area and the rest of the family living unit l Indicates required smoke detector Indicates smoke detector is optional if door is not provided between living and recreational rooms 16 ...

Страница 23: ...e Faulted A detection area which is not secure such as a protected door or window which has been left open causing the control to loose its Ready status Force Arm To override To force the system to arm when one or more zones are not ready Hardwire Zones The six areas of protection referred to as Zones 1 6 on the control station Indicator Lights The ten lights LEDs on the control station Interior T...

Страница 24: ......

Страница 25: ......

Страница 26: ...Notes 20 ...

Страница 27: ...io antenna 2 Reiocate or move lhe alarm control away from the receiver 3 Plug the transformer for the alarm control Into a different outlet so that the receiver and the alarm are on different branch circuits 4 lf necessary the user should consult the afarm deafer or an experienced radiotelevision technlctan for additional suggestions The user may find the following booklet prepared by the Federal ...

Страница 28: ...MOOSE Sentrol Inc resen es the rtght to change specifmtmns wthout notice tJ1991 Sentrol Inc ...

Отзывы: