background image

ITC8113 / TabX® 

 

50

 

© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany 

 

 

11.5 Replacement stick-type battery 

A replacement battery is optionally available for operating the device  

(Article no.: DV-ITCOPT-003 001-AA). 

 

 

 

Please note: This is a UL-certified accessory. 

 

 

 

Содержание TabX ITC8113

Страница 1: ...Updated 2019 08 13 Instruction manual Tablet PCs ITC8113 TabX Version 2 1 Translation of the original instruction manual ...

Страница 2: ... Environmental conditions 9 2 9 Standards 10 2 10 Scope of delivery 11 2 11 Features of the ITC8113 12 2 12 External dimensions ITC8113 14 3 Operating and safety instructions 15 3 1 Operating location 16 3 2 Damage due to improper use 16 3 3 Warranty repairs 16 3 4 Intended use 16 3 5 Improper use 17 3 6 Treatment and disposal of lithium batteries 17 3 7 Electrostatically sensitive components 18 3...

Страница 3: ...h 38 7 3 UMTS LTE optional 38 8 Drives 39 8 1 Hard disk Flash SSD 39 8 2 External drives 39 9 Software 40 9 1 Reinstalling the operating system 40 9 2 Configuration Center 40 10 Technical details 41 10 1 Technical details of the ITC8113 41 10 2 Technical details of the stick type batteries 42 11 Accessories 43 11 1 Transport case 43 11 2 Battery charging station 44 11 3 Replacement power adapter 4...

Страница 4: ...rich Hertz Str 1 72622 Nürtingen Germany 12 Component replacement 64 12 1 Opening the service slot 64 12 2 Changing the mass storage device 66 12 3 Replacing the BIOS battery 67 13 Service support 68 13 1 ADS TEC support 68 13 2 Company address 68 ...

Страница 5: ...al are provided for basic understanding and may differ from the actual design The operator operating company is independently responsible for compliance with and observance of any subsequently introduced technical innovations or new legal requirements as well as for all usual obligations of the operator operating company The original version of this instruction manual was written in German All non...

Страница 6: ... following as ADS TEC 1 4 Relevant device documentation The following documents are decisive to device setup and operation Instruction manual Contains information for installation commissioning and operation of the device along with technical data of the device hardware Website You can download drivers software user manuals leaflets and flyers from the Download section of our website www ads tec d...

Страница 7: ...tified by an arrow SIGNAL WORD Type consequences of hazard Source of hazard Measures to prevent hazard 2 2 Graduation of risk level The signal word classifies the hazard Instructions for preventing the hazard are identified by an arrow 2 3 Explanation of used symbols DANGER Indicates an imminent danger If not avoided death or severe injury will result WARNING Indicates a possible danger If not avo...

Страница 8: ...nd Electronic Equipment Act ElektroG Electrical and electronic devices must not be disposed of with household waste but must rather be taken to a collection point for waste electrical equipment Such a collection point is generally operated by public waste management authorities i e by municipalities Symbol for the protective earth connection 2 5 Data figures and modifications All data text and fig...

Страница 9: ...ngement ADS TEC reserves the right to exercise all rights 2 8 Environmental conditions The device can be put into operation and used under the following conditions Failure to observe any one of these conditions will invalidate the warranty ADS TEC cannot be held liable for any damages arising from improper use and handling Temperature for ITC8113 in operation 0 40 C for storage 20 to 60 C Humidity...

Страница 10: ... requested at http www ads tec de support support anfrage html and is available for download at http www ads tec de support download eg konformitaetserklaerung html The device variants with DisplayPort are certified according to UL 60950 1 Electromagnetic compatibility EMC The product is a class B device Recommendation for use For full compliance with the EMC legislation all components and cables ...

Страница 11: ...device have evident signs of damages caused e g by improper operation or storage conditions or due to improper use or handling the device and accessories must be shut down immediately Ensure that they are secured against being started up accidentally 1 x device 1 x power adapter 20VDC 2 x stick type battery Quick Start Guide Optional scope of delivery ITC8113 accessories acc to delivery note ...

Страница 12: ...nsistently further developed for professional and mobile use High performance brilliant Full HD display and optimised for applications in service environments the new TabX ITC8113 scores high marks both for indoor and outdoor use Front side No Description 1 HD display with 10 finger touch screen 1920 x 1080 pixels 2 Monocoque frame 3 Status LEDs 4 Front keys with lighting ...

Страница 13: ...ITC8113 TabX 13 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany Rear side No Description 4 Battery ejector 5 Set up mechanism 6 Service slot 7 Docking connector ...

Страница 14: ...ITC8113 TabX 14 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 2 12 External dimensions ITC8113 ...

Страница 15: ...nformation All users must read this manual and have access to it at all times Installation commissioning and operation may only be performed by qualified and trained personnel The safety notices and the manual itself must be observed by all persons who work with this device At the installation site the valid guidelines and regulations for accident prevention must be observed The manual contains th...

Страница 16: ...evice must not be exposed to direct radiation by sunlight or any other light source 3 2 Damage due to improper use Should the device have evident signs of damages caused e g by improper operation or storage conditions or due to improper use or handling the device must be shut down immediately Ensure that it is secured against being started up accidentally 3 3 Warranty repairs During the device war...

Страница 17: ...the handling of the device 3 6 Treatment and disposal of lithium batteries This device contains a BIOS battery The battery has a life cycle of 3 5 years depending on which load is applied This device contains up to two rechargeable stick type batteries for supplying the device in mobile use WARNING Danger of explosion fire and chemical burns Danger of explosion if using incorrect battery types Bat...

Страница 18: ...ergised conditions Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges The provisions of DIN EN 61340 5 1 DIN EN 61340 5 2 apply 3 8 Cleaning the device For cleaning we recommend applying a cleaning agent for household use Additionally we have tested the following disinfectant Meliseptol produced by B Braun Melsungen AG It c...

Страница 19: ...s be connected with the connector housing EMC For embedded operating systems the interfaces must be explicitly enabled and the necessary drivers installed in order to use them Recommendation for use When using accessories proceed according to chapter Accessories 4 1 Procedure Datentechni k Inbetriebnahme Rei henfolge der Inbetriebnahme R eihenfolge der Inbetriebnahme für VMT 60xx Serie 1 mod_12220...

Страница 20: ...T GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 5 Operation 5 1 Full HD display The device is equipped with a full HD display with multifunction touch screen The non reflective display offers a maximum resolution of 1920 x 1080 pixels ...

Страница 21: ...rating system Recommendation for use The touch calibration data is stored independent of the operating system and requires no additional calibration by the user Pos 23 D atentechni k Bedienung Status Anzeig en SYS LED SYS LED für VMT60xx Serie 2 mod_1260525540269_6 doc 6876 Recommendation for use With older operating systems a driver is required for the touch screen functionality The appropriate d...

Страница 22: ... voltage source power supply battery Static Device is connected to a power source power supply battery and switched on Flashing The device is in suspend mode mode can be set via the operating system reactivation via the power button Static Device accesses the mass storage device Power LED Device is not connected to a voltage source Static Device is supplied with charged battery Static Device is su...

Страница 23: ...acity of the battery ies WLAN LED Static WLAN module is not switched on Static WLAN module is switched on Flashing Device is connected to a WLAN network and has data traffic Bluetooth LED Static Bluetooth module is deactivated Static Bluetooth module is activated Flashing Device is connected to a Bluetooth subscriber and has data traffic ...

Страница 24: ... 5 4 Front panel operation keys Recommendation for use After activating the operating system the soft keyboard can be opened using the corresponding front key If the soft keyboard is not installed it can be added Details can be found in the instruction manual for the Configuration Center ...

Страница 25: ...second keyboard level This key must be pressed simultaneously with the desired function key Level 1 Change task Alt ESC in Windows Level 2 Increase system volume Level 1 Switch from landscape display view to portrait display view Level 2 Decrease system volume Level 1 Right mouse key function Level 2 Increase display brightness Level 1 Activate and deactivate the soft keyboard for letter character...

Страница 26: ...ed by simply pressing the respective key The second function level of each key small icon in the upper right can be executed by first pressing the Fn key followed by the desired function key It is important that the Fn key always be kept held down to activate the second function level Recommendation for use If the soft keyboard is not installed level 1 of the ABC key has no function Furthermore no...

Страница 27: ...in to return to the initial state The function ensures that the preset calibration for 0 or 90 is always loaded ATTENTION Keep the air outlet at the right near the card slots free of obstruction To protect the device from overheating make certain that the air outlet slots are not covered or that the air outlet is not impeded ouch Scr een Touchscreen für VMT 60xx 1 mod_1246361069977_6 doc 5853 ...

Страница 28: ...reaching of IP protection IP protection is no longer provided if the rubber covers are open Only open the rubber covers when using the interfaces Recommendation for use Only use the accessories and replacement parts released by ADS TEC 6 1 Interfaces on the side 6 1 1 Standard version Pos 26 D atentechni k Schnittstell en Spannungsversorgung Spannungsversorg ung für VMT60xx Seri e 2 mod_1260450284...

Страница 29: ...6 D atentechni k Schnittstell en Spannungsversorgung Spannungsversorg ung für VMT60xx Seri e 2 mod_1260450284020_6 doc 6853 No Description 1 DisplayPort Video OUT 2 USB interfaces 3 LAN interface 4 Power supply 5 Depending on the version of the device BNC connector analogue video IN or LAN via ODU connector or None 1 2 3 4 5 ...

Страница 30: ...nrich Hertz Str 1 72622 Nürtingen Germany 6 2 Power supply via the power adapter Technical data of the power adapter Power consumption 70 watts Input voltage 100 240 VAC Output voltage 20 VDC Grid frequency 47 63 Hz Current consumption 3 5A 230 VAC ...

Страница 31: ...ed with the hot swap function which allows batteries to be changed without restarting The batteries are automatically charged during mains operation 20 VDC Recommendation for use If both batteries are to be changed while in operation power is to be supplied via the included power adapter If changing just one battery it can be changed without an external power supply Pos 29 D atentechni k Schnittst...

Страница 32: ...espective key The charge state can be queried via the Test Power button on the battery The charge state indicator illuminates for a few seconds and displays the current charge state on a scale from 0 to 100 LED State of charge Red LED blinks 0 10 Red LED on 11 32 Red and orange LEDs on 33 65 Red yellow and orange LEDs on 66 94 All the LEDs on 95 100 Recommendation for use If the device is in opera...

Страница 33: ...ith the USB 3 0 standard requirements USB 3 0 Pin Signal 1 VBUS 2 D 3 D 4 GND 5 StdA_SSRX 6 StdA_SSRX 7 GND_DRAIN 8 StdA_SSTX 9 StdA_SSTX Recommendation for use The recessed USB interface not available in the Display port version enables the use of a USB dongle This can be operated in the device The two side USB interfaces are designed for 1A Exception the recessed USB interface which is designed ...

Страница 34: ...this network topology must be observed If the drivers necessary for the function are not installed they can be downloaded from the website www ads tec de 10 100Mbit Pin Signal 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC 1000 BaseT Pin Signal 1 D1 2 D1 3 D2 4 D3 5 D3 6 D2 7 D4 8 D4 Pos 32 D atentechni k Schnittstell en Funknetzwer kkar te Funknetzwer kkarte für VMT 6000 Serie 2 mod_1260517076470_6 doc ...

Страница 35: ...l IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 6 6 Microphone The device is also equipped with an internal microphone on the front side The microphone can be configured via the integrated volume control in the operating system ...

Страница 36: ... by using the device front keys When activating the described key combinations the volume level is modified accordingly If the soft keyboard has been installed the system volume is additionally displayed by a bar graph Button combination increase volume Pos 29 Datentechnik S chnittstellen USB Anschluss USB A nschluss für VMT 60xx 2 mod_1260457598122_6 doc 6860 Button combination reduce volume ...

Страница 37: ...tworks or compatible terminals Recommendation for use The appropriate drivers can be downloaded from the website http www ads tec de for the respective device series 7 1 WLAN The device is equipped with a wireless LAN card and can be integrated wirelessly in any IT infrastructure Recommendation for use The wireless card supports the following standards Wireless LAN 802 11 a g n ...

Страница 38: ...d 7 3 UMTS LTE optional The device is equipped with a mobile communications module and is able to communicate with the Internet even without a wireless infrastructure Recommendation for use An activated SIM card is required for use There are costs fees associated with mobile data use Further information is available from your mobile provider The SIM card is to be inserted while the device is in th...

Страница 39: ...ke Exter ne Laufwerke Exter ne Laufwer ke für OPC 5112 5115 5117 IPC 1100 CPC PLC OTC ITC VMT Serie 0 mod_1158926656205_6 doc 563 8 2 External drives External storage media can be connected via USB interfaces Note here the connecting lines in chapter Interfaces ATTENTION Connecting or disconnecting external drives in operation is not admissible since it cannot be excluded that the drive might be i...

Страница 40: ...sert an operating system CD into the external drive 4 Select booting from the external drive in the boot menu and start 5 Install the operating system and set the basic data 6 For touch screen devices the touch screen driver and soft keyboard should be installed for full function Installation of the operating system via PXE Alternatively the operating system can also be installed over the network ...

Страница 41: ...s a load capacity of max 1 A Optional 1 x USB 3 0 recessed installation max 1 8 A Docking connector Optional Display Port Power adapter External power adapter input 100 240 VAC output 20 VDC BIOS battery Lithium battery CR2032 230mAh Article no ADS TEC DZ SONS 04075 1 Operating system Windows Embedded Standard 7 64 bit Windows Embedded 8 1 Industry Pro 64 bit Windows 10 IoT Protection class IP 53 ...

Страница 42: ...with an initial state of charge of 50 and after the time has elapsed at least 80 of the nominal capacity are still available Lower storage temperatures will slow down the ageing process Recommendation for long term storage For storing the battery in an optimum way at the beginning of storage the battery should have a state of charge of 30 70 Self discharge of the cells The following applies for th...

Страница 43: ...ansport case The optionally available transport case allows the device to be transported safely In addition the transport case offers the possibility to store accessory parts such as batteries power adapters and software Exterior view of sample case Please note The transport case is not a UL certified accessory ...

Страница 44: ...rging station A battery charging station is optionally available for charging the device batteries Article no DV ITCOPT 002 001 AA The battery charging station has two battery slots Two batteries can thereby be charged simultaneously Please note The battery charging station is not a UL certified accessory ...

Страница 45: ... starting up the battery charging station a 20 VDC power adapter must be connected Connect the power adapter on the rear side of the battery charging station The power adapter for the device can be used to supply power to the battery charging station 20 VDC Recommendation for use Make certain that the system LED illuminates green ...

Страница 46: ...to the battery slots so that there is a connection between the charging contacts of the battery charging station and the batteries Recommendation for use If the battery was correctly inserted in the battery charging station an audible signal sounds and the charging process begins An audible signal also sounds when a battery is removed ...

Страница 47: ...IOUR DESCRIPTION No battery inserted Static Battery fully charged Static Battery is faulty CHARGE LED INDICATOR Battery is not charging Flashin g Battery is charging SYS LED INDICATOR Device is not connected to any voltage source power supply battery Static Device is connected to a power source power supply battery and switched on Static Device not ready for operation defective power supply ...

Страница 48: ... ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany PICTOGRAPHIC REPRESENTATION Battery is charging Battery fully charged Device is not ready for operation defective power source Battery is faulty ...

Страница 49: ...Please note This is a UL certified accessory 11 4 Vehicle power adapter A vehicle power adapter is optionally available for operating the device Article no DV ITCOPT 005 001 AA This can be used to conveniently supply the device with power in vehicles Please note The vehicle power adapter is not a UL certified accessory Technical data of the power adapter Power consumption 90 watts Input voltage 11...

Страница 50: ...IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 11 5 Replacement stick type battery A replacement battery is optionally available for operating the device Article no DV ITCOPT 003 001 AA Please note This is a UL certified accessory ...

Страница 51: ... stable mounting solution for every installation site The device can be connected to the docking station using the docking connector on the rear side of the device Please note This is a UL certified accessory The docking station is available in two versions The first version is used strictly to hold the device The second version pictured has a docking connector that transfers data to the interface...

Страница 52: ...ket to a table or a wall Use adequate screws and plugs depending on the load bearing capacity of the supporting surface of the table or wall for safe mounting The type of screw connection required e g number diameter quality type and length of screws and any special wall plugs or anchors required depends largely on the fastening interface provided by the customer e g on a steel plate wooden plate ...

Страница 53: ...H Heinrich Hertz Str 1 72622 Nürtingen Germany MOUNTING THE DEVICE TO THE DOCKING STATION 1 Place device on red marking behind the turquoise marking 2 Push device to the back onto the docking station You should feel the device click into place ...

Страница 54: ...ICE FROM THE DOCKING STATION 1 Push the turquoise release downward and hold down 2 Tilt the device forward slightly 3 Lift the device upward to disconnect and remove it from the docking station The docking solution shown here illustrates the mechanical release A lockable docking solution is also available ...

Страница 55: ...ITC8113 TabX 55 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 11 7 Tip up feet The tip up feet enable comfortable operation anywhere ...

Страница 56: ...e use The 3 point strap can be mounted directly to the device and makes the device a mobile workplace Please note The 3 point strap is not a UL certified accessory 1 x DZ MECH 33255 1 A M5x16 flat head screw galvanised DIN 921 2 x DZ MECH 33255 2 flat head screw M5x20 galvanised DIN 921 B 3 x DZ MECH 31033 0 Strap eyelets 1 x DZ MECH 31039 0 3 point strap ...

Страница 57: ...72622 Nürtingen Germany MOUNTING THE 3 POINT STRAP TO THE DEVICE 1 First attach the strap eyelets to the device In doing so the appropriate mounting option must be selected for left or right handed users Left handed users white marking Right handed users red marking ...

Страница 58: ... 1 72622 Nürtingen Germany 2 Screw down the strap eyelets at the marked positions as shown in the figure Recommendation for use Tighten the screws to max 120 Ncm The strap eyelets should still move without loosening the screw Mounted state for right handed users ...

Страница 59: ...622 Nürtingen Germany 3 The shoulder strap can be attached to the strap eyelets via the carabiners The device is ready for mobile use Recommendation for use The tilt adjustment of the shoulder strap upper right should always be attached to the upper side of the device ...

Страница 60: ...ITC8113 TabX 60 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany ...

Страница 61: ...shoulder strap a hand strap is available for mobile use The hand strap can be mounted directly on the device and turns the device into a mobile workplace Please note This is a UL certified accessory 2 x supplied screws 1 x hand strap MOUNTING THE HAND STRAP ON THE DEVICE 1 The hand strap is to be mounted at the marked bore holes ...

Страница 62: ... tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 2 Screw down the hand strap at the marked positions as shown in the figure Recommendation for use Tighten the screws to max 120 Ncm 2 Mounted hand strap ...

Страница 63: ...strial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 11 10 Protection cover The optionally available protection cover offers protection against transport damages Please note The 3 point strap is not a UL certified accessory ...

Страница 64: ...e certain that all cables are disconnected and that no voltage is connected to the device 12 1 Opening the service slot Remove the six screws for the service slot on the rear of the device The screws can be removed with a size Tx 8 screwdriver The rear cover can be removed via the groove in the service slot on the bottom side ...

Страница 65: ...ITC8113 TabX 65 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany By removing the service slot cover it is possible to replace the following components 1 HDD SSD 2 Lithium battery ...

Страница 66: ...Nürtingen Germany 12 2 Changing the mass storage device Removal The extraction aid on the mass storage device should be used for removing Pull out the storage medium Installation The mass storage device must be carefully inserted into the slot and should noticeably engage ...

Страница 67: ...e same type The battery type to be used is Lithium battery CR2032 230mAh make VARTA available under ADS TEC part number DZ SONS 04075 1 Ensure the correct polarity when inserting the battery ATTENTION There is a risk of explosion if the battery is replaced with the wrong type or with the wrong polarity Observe the regulations for environmentally sound disposal of used batteries ...

Страница 68: ... not be able to answer such questions ADS TEC does not provide support services for any device that was not purchased directly from ADS TEC In this case maintenance and support is provided by the partner company 13 1 ADS TEC support The ADS TEC support team is available for inquiries from direct customers between 8 30am and 5 00pm Monday to Friday The support team can be reached via phone fax or e...

Отзывы: