background image

VMT6010/6012/6015

 

 

43

 

 

© ads-

tec GmbH • Heinrich-Hertz-Str. 1 • D-72622 Nürtingen

  

 

 

10   Service & Support 

ads-tec and its partner companies offer your customers a comprehensive service and support, which 
ensures availability of a fast and competent support with respect to all upcoming questions related to 
ads-tec products or assemblies. 

 

Since the devices manufactured by ads-tec are also used by associate companies, these devices might 
be configured in customer specific ways. Should any questions arise with respect to these specific 
configurations and software installations, they can only be answered by the system manufacturer.  

For devices not directly purchased from ads-tec we don't deliver any support. The support is delivered 
by our associate companies in these cases. 

 

10.1  ads-tec Support 

 

The ads-tec support team is available for direct clients from Monday to Friday from  

08:30 AM to 05:00 PM using the following phone number: 

Phone:  +49 (0) 7022 2522-202 

Fax: 

+49 (0) 7022 2522-2602 

Email: 

[email protected]

 

 

Alternatively, you can contact us by completing a support form on our website 

www.ads-tec.de

.  

Our Support team will then get in touch with you as soon as possible. 

 

10.2  Company adress 

 

ads-tec GmbH 

Heinrich-Hertz-Str. 1 

D-72622 Nürtingen 

Germany 

 

Phone:  +49 (0) 7022 2522-0 

Fax: 

+49 (0) 7022 2522-400 

E-Mail:  [email protected] 

Email:  [email protected] 

Home:  www.ads-tec.de 

 

 

Содержание VMT6010

Страница 1: ...User Manual Terminals VMT6010 6012 6015 Version 2 0...

Страница 2: ...Damage Caused By Improper Use 8 2 3 Warranty Repair 8 2 4 Treatment and Disposal of Lithium Batteries 8 2 5 Notes on Safety 8 3 Mounting 9 3 1 External Device Dimensions VMT6010 9 3 2 External Device...

Страница 3: ...9 Serial COM Interface RS232 31 7 Drives 32 8 Software Driver Installation 33 8 1 Configuration Center 35 8 1 1 Automatic Brightness Adaption 36 8 1 2 COM Input Configuration 37 8 1 3 Ignition 37 8 1...

Страница 4: ...all currently applicable legal requirements and regulations The operator operating company is independently responsible for compliance with and observance of any subsequently introduced technical inn...

Страница 5: ...erminate any warranty for this device Ads tec cannot be held liable for any damages arising due to improper use and handling Temperature for devices without a heater in operation 20 55 C for storage 3...

Страница 6: ...pliance with the EMC legislation For this reason screened bus and LAN cables including screened connectors must be used and installed according to the instructions in this user manual Note By using th...

Страница 7: ...y Please check that all of the following components are contained in the packaging Scope of Delivery VMT6000 series 1 x device 4 pin Lead through connector from Phoenix Contact COMBICON MC 1 5 4 STF3...

Страница 8: ...e most important instructions on how to use this device in a safe way Appropriate storage proper transport installation and commissioning as well as careful operation are prerequisites for ensuring sa...

Страница 9: ...exposed to higher temperatures the faster it ages Warning There is an acute risk of explosion should the wrong type of battery be used Warning Do not put lithium batteries into a fire do not solder on...

Страница 10: ...VMT6010 6012 6015 9 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 3 Mounting 3 1 External Device Dimensions VMT6010 Abb 1...

Страница 11: ...VMT6010 6012 6015 10 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 3 2 External Device Dimensions VMT6012 Abb 2...

Страница 12: ...VMT6010 6012 6015 11 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 3 3 External Device Dimensions VMT6015 Abb 3...

Страница 13: ...ng The device must be switched off before connecting or disconnecting any cables in order to prevent damage to the electronics The device may only be switched on after acclimatising to the ambient tem...

Страница 14: ...ation Pos 18 D atentechni k Inbetri ebnahme R eihenfolg e der Inbetriebnahme R ei henfolge der Inbetriebnahme f r VMT 60xx Seri e 1 mod_1222073159179_6 doc 4100 4 2 Order of Steps during Commissioning...

Страница 15: ...bsbereitschaft pr fen f r OPC C PC PLC OTC ITC VMT Serie Monitore IPC 5100 5500 2400 1100 0 mod_1158905578361_6 doc 381 4 3 Check for operational Readiness Check the device for any hidden damage poten...

Страница 16: ...front panel are pre allocated with the following functions by a specific driver in the soft keyboard Level 1 Activate and deactivate the soft keyboard for letter character input by using the touch sc...

Страница 17: ...d with an operating system Windows CE 6 0 Windows XP embedded or Windows XP Professional ex works and a soft keyboard is installed The keys on the front panel are pre allocated with the following func...

Страница 18: ...rdance with customer specific requirements The above described functions are pre set ex works Pos 21 D atentechni k Bedienung Softkeyboard Softkeyboar d f r VM T 60xx 1 mod_1228750145198_6 doc 4251 5...

Страница 19: ...first Due to differences in programming of a large variety of software programmes we cannot ensure that the soft keyboard works properly with all available software When deactivating the soft keyboar...

Страница 20: ...ystem LED Indicators Behaviour Description static Device is connected with a power source and switched on flashing Volume display brightness is being modified static Minimum maximum value for volume d...

Страница 21: ...able for automatic system login The user applies the RFID tag like a key and requires neither user name nor password For authentication the key card or the RFID chip are held in front of the position...

Страница 22: ...epending on the hardware configuration a MIFARE or LEGIC RFID reader is installed MIFARE 1 To test the RFID function select the application ads tec RFID sample application on the pre installed Configu...

Страница 23: ...12 If no RFID reader is found you have the opportunity to select the serial port to which the RFID reader is connected manually Abb 13 After selection of the COM port the application opens the por whi...

Страница 24: ...of an RFID reader or a bar code scanner arrive automatically without the active application Abb 14 The functionality of the application can be integrated via the Configuration Center surface at any t...

Страница 25: ...igure shows the socket inside the device Pin Number Signal Name 1 PE 2 0V DC 3 Ignition contact 4 24V DC Voltage tolerance Input voltage 24 V DC 20 Current consumption The current consumption of this...

Страница 26: ...ectrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you have...

Страница 27: ...nition function are available from ads tec Note Switching the device ON or OFF by using the Power button will override the ignition function That means if the device is switched off by using the Power...

Страница 28: ...volume can be set up by using the device front keys When activating the described key combinations the volume level is modified If the soft keyboard is installed the system volume is additionally disp...

Страница 29: ...ces can be individually locked by using the Lock USB software tool USB Interface in Front panel One USB interface can be accessed from the front The interface is located under a plastic cover undernea...

Страница 30: ...tzwer kanschluss RJ45 f r VMT60xx 2 mod_1260451135970_6 doc 6856 6 7 Netzwork Connection RJ45 If the drivers required for functioning are installed on the device the control system may be integrated i...

Страница 31: ...eshared key WPA enterprise EAP TLS Specifications of this network topology must be observed in this case Note As an option this device can be equipped with an internal antenna and an external antenna...

Страница 32: ...by using a commercially available 9 pin SUB D cable Note Pin 9 of the serial interface connector can be used for additional switching of a 5V power supply e g for operating a serial barcode scanner Th...

Страница 33: ...ofessional Pos 35 D atentechni k Laufwer ke Exter ne Laufwerke Exter ne Laufwer ke f r OPC 5112 5115 5117 IPC 1100 CPC PLC OTC ITC VMT Serie 0 mod_1158926656205_6 doc 563 Externe Laufwerke By default...

Страница 34: ...g one of the existing interfaces An external keyboard is required for installation Installation of the Operating System The device does not have any integrated CD drive The installation of the operati...

Страница 35: ...TouchScreen folder Follow the on screen instructions and acknowledge the licence terms and conditions Once the installer has completed the installation shut down the computer and restart it subsequent...

Страница 36: ...ads tec applications are installed on the device Additionally you can start any of these applications from the Configuration Center by double clicking on it Information In the Information section devi...

Страница 37: ...both modes Note The threshold for Day Night mode has to be determined individually by the user for each device The day mode is enabled as soon as the ambient brightness is high enough The display bri...

Страница 38: ...ication that uses the COM2 port forwarded Note Unnecessary applications that use the COM2 port must be stopped before running the COM input configuration Because of different programming data on vario...

Страница 39: ...output in the event that a USB port is locked or not Additionally the locking process can be logged in the event log Password Protection In order to avoid any unauthorised access to the USB Lock prog...

Страница 40: ...button configuration allows to change the behaviour of the ON OFF pushbutton Regular Mode The ON OFF pushbutton switched the device on and off Secure Mode The ON OFF pushbutton only switches the devic...

Страница 41: ...order to test the function of the RFID reader Note In the Interfaces section of the manual you can find more information about the topic of RFIDs 8 1 7 Softkeyboard Here you can configure the soft key...

Страница 42: ...st be installed from the enclosed service CD in order to ensure usability of the 5 keys except for the VMT series where you have 6 keys underneath the monitor The installation has to be carried out as...

Страница 43: ...Flash SSD via internal USB connections 1 x Flash SSD via internal USB connections 1 2 x Flash SSD via internal USB connections 2 Alternativ 2 5 Automotive Hard Disk with min 40 GB SATA 2 5 Industrial...

Страница 44: ...ly be answered by the system manufacturer For devices not directly purchased from ads tec we don t deliver any support The support is delivered by our associate companies in these cases 10 1 ads tec S...

Страница 45: ...VMT6010 6012 6015 44 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 11 Declaration of CE Conformity VMT6008...

Страница 46: ...VMT6010 6012 6015 45 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen VMT6010 Glossar...

Страница 47: ...VMT6010 6012 6015 46 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen VMT6012...

Страница 48: ...VMT6010 6012 6015 47 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen VMT6015 Glossar Glossar...

Отзывы: