Advanced RF Technologies, Inc.
46
VSWR
<
1.5 : 1
Dry Contacts
NFPA 1221 2016 Code Compliant
Remote Alarming /
Network Management
Dry Contacts, Web-GUI, SNMP, SNMP-Traps (External
Wireless Modem Required)
Humidity
5% - 90% RH Condensed
Operating at Ambient Temperature
-40°F to +140°F (-40°C to +60°C)
8.2
Mechanical Specifications
Table 8-2
Mechanical Specifications
Parameters
Specifications
Comments
Dimensions W x D x H
12.0 x 11.9 x 21.3 in (w/o mounting bracket)
Weight
64.0 lbs (w/o mounting bracket)
RF Connector
4.3-10 (Female)
Weather Resistances
IP66
8.3
Power Specifications
Table 8-3
Power Specifications
Parameters
Specifications
Comments
AC Power
100 -240 VAC, 60 Hz (Free Voltage)
AC Supply Protection
Fuse & Circuit Protector
T6.3L250V
Battery Backup
Power Consumption
AC 221.52W (110V/1.54A), DC 24V/9.23A
Ground
External Threaded Stud
8.4
Warranty & Certificates
Table 8-4
Warranty & Certificates
Parameters
Specifications
Comments
MTBF
> 100,000 Hours
Ambient
Compliance
UL60950
FCC CFR47 part 15
FCC CFR47 part 90
Warranty
2 Years
Содержание PSR-78-9537
Страница 30: ...Advanced RF Technologies Inc 30 5 2 Status Tab Figure 5 2 Status Tab ...
Страница 33: ...Advanced RF Technologies Inc 33 5 3 Control Tab Figure 5 7 Control page ...
Страница 36: ...Advanced RF Technologies Inc 36 5 4 Install Tab 5 4 1 Install Figure 5 12 Install Page ...
Страница 47: ...Advanced RF Technologies Inc 47 9 MECHANICAL DRAWING Figure 9 1 PSR 78 9537 Mechanical Drawing ...