5.3.4
Alarm Settings
Figure 5-11 Alarm Settings
DL Signal Low Level: Allows the user to specify how low the signal can be before triggering a “Downlink Signal
Low” soft-fail alarm
DL Signal Not Detected Level: Allows the user to specify how low the signal can be before triggering a “Downlink
Signal Not Detected” soft-fail alarm
DL RF Power Level: Allows the user to set a maximum deviation value for the downlink RF power before
triggering a “DL RF Power Level” soft-fail alarm
-
For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power should
be 10 dBm. If the Downlink RF Power alarm value is set to 6dB, then a soft-fail alarm will trigger if the
output power falls below 4 dBm
DL Over Power Level: DL Over Power Alarm will trigger when the DL output level exceeds this level
UL Over Power Level: UL Over Power Alarm will trigger when the UL output level exceeds this level
Battery Check:
Check All – All battery related alarms are checked which include Battery Fail, Battery Not Installed, Low
Battery, and Battery Not Charge
Except Install – Only Battery Fail, Low Battery, and Battery Not Charge alarms are checked
Check Off – Does not perform any battery check
Battery Not Charge Check:
On – Checks for the Battery Not Charge alarm
Off – Disables the check for the Battery Not Charge alarm
Содержание PSR-78-9537
Страница 30: ...Advanced RF Technologies Inc 30 5 2 Status Tab Figure 5 2 Status Tab ...
Страница 33: ...Advanced RF Technologies Inc 33 5 3 Control Tab Figure 5 7 Control page ...
Страница 36: ...Advanced RF Technologies Inc 36 5 4 Install Tab 5 4 1 Install Figure 5 12 Install Page ...
Страница 47: ...Advanced RF Technologies Inc 47 9 MECHANICAL DRAWING Figure 9 1 PSR 78 9537 Mechanical Drawing ...