DO NOT APPLY AC POWER TO THE BDA UNTIL CABLES ARE CONNECTED TO BOTH PORTS OF
THE BDA AND THE ANTENNAS.
-
Prior to equipment use, the device must be registered with the FCC. This can be done through the FCC’s
website at https://signalboosters.fcc.gov/signal-boosters
1.
To mount on a wall, use the appropriate screws and anchors to attach the BDA to the wall using the four
mounting holes with the included wall mount bracket.
2.
Ensure that the isolation between the donor antenna and the serving antennas is at least 15 dB greater
than the BDA gain.
3.
Connect the cable from the donor antenna to the BDA connector labeled “DONOR” and the cable from the
serving antennas to the BDA connector labeled “SERVER”.
4.
Wire the AC power source to the AC terminal block inside of the wiring compartment of the BDA and secure
the line using the appropriate conduit and conduit hub connectors.
5.
Power on the repeater by flipping the AC switch to the ON position located on the left side of the PSU.
6.
Installation of the BDA is now complete. Adjust the gain controls to suit the specific signal environment
through the GUI on your PC.