Spectral sensitivity

 

Figure 4.

 Spectral sensitivity (Contour IR digital camera)

 

 

Содержание IRVI Contour IR

Страница 1: ...Contour IR Digital Infrared cameras Manual ...

Страница 2: ...www ir viewers com 2 sales ir viewers com ...

Страница 3: ...3 Safety requirements 4 About 5 Operation 5 PC requirements 8 Software usage 9 Software set and features 10 Applications development by the customer 10 The Maintenance instruction 11 Spectral sensitivity 13 Power density 14 Technical information 15 Warranty 19 ...

Страница 4: ...stomer must consider protective measures if necessary While assembling or operating camera do not stare at the direct laser or other source light even with safety goggles Camera is not protected from direct high intensity radiation Use it with caution and appropriate attenuation if used in direct illumination mode Electrical safety requirements must be complied while operating this device ...

Страница 5: ...ensitivity and microlenses on photocells for better photon absorption and amplification of each pixel element Camera is connected to PC via USB 2 0 or USB 3 0 interface Operation CAUTION Do not use direct powerful laser radiation on a sensor CAUTION Use filters attenuators or beam splitters to decrease of laser radiation 1 Install the camera driver and software from provided USB key 2 Connect came...

Страница 6: ...tion decrease any extrinsic light to increase noise to signal ratio Use cut off or interference filters for raise contrast 2 1 1 Mini B USB video output 2 Tripod thread inch 3 IR cut off filter 4 Focus ring 5 Diaphragm 6 C mount ring Figure 1 Contour IR Digital camera 3 6 4 5 6 ...

Страница 7: ...www ir viewers com 7 sales ir viewers com Figure 2 IR cut off filter transmittance ...

Страница 8: ...mputer During installation camera drivers depending on your operating system will be installed To run CONTOUR IR application Microsoft NET 4 6 Framework or later must be installed The installer detects if NET framework is missing and prompts its installation NOTE High performance computer is recommended for best motion picture without stuttering Otherwise you might need to reduce frame rate or cho...

Страница 9: ...ects camera devices and enumerates them in Device list box 2 To start the capture select your camera in the list After selection the software will read camera s allowed settings and update the interface according present settings 3 Use the software provided functionalities shown in Fig 2 to suit your application needs Figure 3 Software controls description ...

Страница 10: ...n pulse mode with short exposures is useless there will be visible just one or several lines of the entire frame Gain factor is 30 dB Gamma correction can be deactivated from the driver bookmark There is no external synchronization Uncompressed video record function is available Applications development by the customer The Contour IR digital camera is supplied with the WDM driver that implements t...

Страница 11: ...icrosoft website DirectShow https docs microsoft com en us windows win32 directshow directshow The Maintenance instruction Keep device away from mechanical damage and moisture Always use a protective case while transporting equipment While changing an objective do it in clean environment to reduce chances of dust particles falling onto the sensor Protect the lenses from dirt and grease It may dete...

Страница 12: ...perience some image flickering and connection loss In this case try to reconnect camera as many times as it takes Before that end all related tasks with Contour software in Windows Task Manager If camera experiencing image flickering after performing described actions try to lower the Frame rate and Resolution through the software These actions may not help if your PC does not support Contour soft...

Страница 13: ...www ir viewers com 13 sales ir viewers com Spectral sensitivity Figure 4 Spectral sensitivity Contour IR digital camera ...

Страница 14: ... com 14 sales ir viewers com Power density The approximate minimum of power density of radiation on an object at the signal to noise ratio 10 20dB on a 0 15m distance Figure 5 Power density Contour IR digital camera ...

Страница 15: ...ange 0 05m to inf Sensor CMOS 1 3 1280 W x 960 H Size of pixel 3 75 x 3 75 µm Dynamic range 60 dB Relation signal to noise 54 dB Format 1 1280x960 4 8 12 5 16 25 30 Hz Format 2 1280x720 5 10 15 20 30 40 Hz Format 3 800x600 6 25 12 5 20 30 40 50 Hz Format 4 640x480 8 16 25 32 50 64 Hz Range of exposure 34µs 34ms Temperature range 5 40 C Weight 0 2 kg Dimensions 49x49x75 mm C mount adapter included ...

Страница 16: ...6 sales ir viewers com Standard kit includes IR camera with F1 4 25mm with internal iris C mount adapter Mounted IR cut off filter USB cable USB key with software and drivers Manual Tripod Case Figure 6 Standard camera kit ...

Страница 17: ...www ir viewers com 17 sales ir viewers com Accessories available upon request Neutral density filter for lens 1X 1 5 2 1064nm Figure 7 Neutral density filter transmittance ...

Страница 18: ...8 sales ir viewers com Zooming lens 5 50mm FOV 50 5 3 6 2 6 1 6 4 6 5 6 Figure 8 Neutral density filter transmittance 1 IR cut off filter 2 Zooming or magnification 1X 10X 3 Diaphragm 4 Focusing ring 5 CS mount thread 1 32 ...

Страница 19: ...nths from the date it was sold to the consumer Claims not accepted and warranty repair are not made because of the improper use or incorrect service and maintenance of product instructions The company shall not accept warranty claim non authorized alteration disassembling of device mechanical or any external damages if 2 year warranty term has expired Serial No Version No Spectral range Date of Is...