164
Motion Control Theory
level 2 position error settings, the controller executes Servo-Off
operation to both axes.
The setup value of this protection mechanism is to set axis
parameter of slave axis by 1: master axis selected to follow and 2:
two level of position error protection. Start up gantry mode with
APS_start_gear (slave axis ID) after set up is completed. After the
gantry mode is active, only the master axis need to be operated
and the slave axis functions exactly the same as the master axis
does.
4.10.2 High Speed Position Compare Trigger
This controller provides Compare trigger with structure as shown
in figure below. Trigger is sent by TRG0 ~3. You can set up two
trigger output formats. The one is pulse output and other is level
toggle output. Length and logic of pulse signal can be adjusted by
embedded PWM module. The PWM signal can be generated in
two ways. The one is to generate trigger by manual trigger by
calling API. The other is compare trigger that can be further
divided into linear compare and table compare. Any one of these
triggers is acceptable to PWM. Manual trigger and compare trigger
are described in sections below.
Param. No.
Define symbol
Description
60h (96)
PRA_GEAR_MASTER
Gear master
63h (99)
PRA_GANTRY_PROTECT_1
Gantry mode protection level one
64h (100)
PRA_GANTRY_PROTECT_2
Gantry mode protection level two
Содержание PCI-8254
Страница 2: ...ii Revision History Revision Date Description 2 00 2014 08 13 First release ...
Страница 8: ...viii Table of Contents Important Safety Instructions 209 Getting Service 211 ...
Страница 12: ...xii List of Figures ...
Страница 14: ...xiv List of Tables ...
Страница 24: ...10 Introduction ...
Страница 54: ...40 Getting Start with The Installation ...
Страница 78: ...64 Signal Connection ...
Страница 111: ...Motion Control Theory 97 PCI 8254 PCI 8258 MCP2 Bode plot page ...
Страница 165: ...Motion Control Theory 151 PCI 8254 PCI 8258 Example Figure 4 55 Continuous interpolation examples ...
Страница 222: ...208 Motion Control Theory ...