28
Operation Theory
4.1
AD Conversion and Preloaded Trigger
4.1.1
ADC
The PCI-8136 provides 6 differential ADC channels. Each channel
consists of two inputs. One for a (+) signal and the other for a (-)
signal. The input signal may have a voltage range from –10 ~
+10V or current range from –20mA ~ 20mA. The following figure
show the A (voltage or current) to D (value read) converting table.
The zero voltage or current is at value 2000.
Related functions:
_8136_A_Initial
(): please refer to section 5.5
_8136_A_Read_Value
(),
_8136_A_Read_Volt
(): please refer
to section 5.5
4.1.2
Voltage Compare
The voltage compare function allows users to set a compare value
by software function. When one ADC signal reaches the pre-set
value, an interrupt will be generated for corresponding channel.
Relative functions:
_8136_A_Set_Compare_Value
(),
_8136_A_Set_Compare_Volt
(),
_8136_S_Set_Int_Factor
() : please refer to section 5,7
Содержание PCI-8136
Страница 4: ......
Страница 20: ...12 Installation...
Страница 32: ...24 Signal Connections Figure 3 7 Connect to open collector output...
Страница 48: ...40 Operation Theory...
Страница 72: ...64 Function Library...
Страница 78: ...70 Appendix 12 A save finish window will appear 13 Press Exit button to exit utility...
Страница 80: ...72 Appendix Channel 2 Channel 3...
Страница 81: ...Appendix 73 Channel 4 Channel 5...
Страница 82: ...74 Appendix...