58
Function Library
B_8136_P_Set_Output_Type (ByVal CardNo As
Integer, ByVal AxisNo As Integer, ByVal
PulseFmt As Integer) As Integer
B_8136_P_Set_Input_Type (ByVal CardNo As Integer,
ByVal EncNo As Integer, ByVal EncFmt As
Integer, ByVal Mul As Integer) As Integer
B_8136_P_Read (ByVal CardNo As Integer, ByVal
EncNo As Integer, EncData As Long) As
Integer
B_8136_P_Send (ByVal CardNo As Integer, ByVal
AxisNo As Integer, ByVal FrqL As Double) As
Integer
B_8136_P_Stop (ByVal CardNo As Integer, ByVal
AxisNo As Integer) As Integer
B_8136_P_Clear (ByVal CardNo As Integer, ByVal
EncNo As Integer) As Integer
B_8136_P_Set_Compare_Value (ByVal CardNo As
Integer, ByVal EncNo As Integer, ByVal
CompValue As Long) As Integer
B_8136_P_Read_Latch_Value(ByVal CardNo As
Integer, ByVal EncNo As Integer, Value As
Long) As Integer
B_8136_P_Set_Index_Latch (ByVal CardNo As
Integer, ByVal WhichIndex As Integer, ByVal
LatchType As Integer) As Integer
B_8136_P_Read_Index (ByVal CardNo As Integer,
ByVal AxisNo As Integer, Index As Integer)
As Integer
B_8136_P_Change_Speed (ByVal CardNo As Integer,
ByVal AxisNo As Integer, ByVal Frq As
Single) As Integer
@ Argument
CardNo
: card number designated to set (Range 0 - 3)
ChannelNo
: channel number designated to set (Range 0 - 5)
EncNo
: encoder channel number designated to set (Range 0 - 5)
PulseFmt
: Output pulse format
0 = Pulse/Direction
1 = CW/CCW
Содержание PCI-8136
Страница 4: ......
Страница 20: ...12 Installation...
Страница 32: ...24 Signal Connections Figure 3 7 Connect to open collector output...
Страница 48: ...40 Operation Theory...
Страница 72: ...64 Function Library...
Страница 78: ...70 Appendix 12 A save finish window will appear 13 Press Exit button to exit utility...
Страница 80: ...72 Appendix Channel 2 Channel 3...
Страница 81: ...Appendix 73 Channel 4 Channel 5...
Страница 82: ...74 Appendix...