50
BIOS Setup
Automatic Mode
Temperature 1 Limit of OFF
When the temperature (°C) is higher than the set value, Fan1/2
will run at Start PWM speed. When the temperature is lower
than the set value, Fan1/2 will stop.
Temperature 1 Limit of Start
When the temperature (°C) is higher than the set value, Fan1/2
will increase its speed by Slope PWM 1 value.
Fan 1/2 Start PWM
Sets a value to control the fan speed between Limit of OFF and
Limit of Start. Minimum is 0 and Maximum is 127.
Slope PWM 1/2
The Slope PWM Value sets the rate of increase the fan speed
when the temperature is above Limit of Start.