C/C++ Libraries
•
35
Visual Basic(Windows 95)
W_7396_CLR_IRQ (ByVal cardNo As Integer)
@ Argument
cardNo :
The card number of PCI7396 card initialized.
@ Return Code
None
5.11 _7396_Set_Event_Edge
@ Description
This function is used to set the edge trigger of event signal (Pin51)
and external trigger signal (Pin99). The following table shows the
possible settings.
Set_Event_Edge
C0
0
1
External Trigger (Pin99)
Active Low
Active High
Event (Pin51)
Rising Edge
Count
Falling Edge
Count
@ Syntax
C/C++ (DOS)
U16 _7396_Set_Event_Edge (U16 cardNo, U16 *c0)
C/C++ (Windows 95)
U16 W_7396_Set_Event_Edge (U16 cardNo, U16 *c0)
Visual Basic (Windows 95)
W_7396_ Set_Event_Edge (ByVal cardNo As Integer, c0
As Integer) As Integer
@ Argument
cardNo :The card number of PCI7396 card initialized.
c0: The event signal and external clock signal
setting.
@ Return Code
ERR_NoError
5.12 _7396_Cascaded_Timer
Содержание NuDAQ DIN-96DI
Страница 1: ...NuDAQ P C I 7 3 9 6 DIN 96DI DIN 96DO 96 CH Digital I O Cards U s e r s G u i d e ...
Страница 2: ......
Страница 16: ...8 Installation 2 3 PCI 7396 Layout Figure 2 1 PCI 7396 Layout ...
Страница 24: ...16 Registers Format BASE 07h x x x x x x x x P1n n port number Set to be 0 for input port 1 for output port ...