background image

 

64 

MECS-6110 

5.3.9  Sub-Menu: Intel(R) I210 Gigabit Network Connection 

This setup page is shown when “Network” setting in Boot page is set to “UEFI”. When the 
BIOS boots the system, it will launch the onboard Ethernet I210 controller’s UEFI driver. The 
driver provides a setup page for configuring Ethernet parameters and shows information 
about Ethernet controller. When the Ethernet’s UEFI driver is not executed, this setup page 
will not be shown. 
 

 

 

BIOS Item

 

Options

 

Description

 

NIC Configuration

 

 

For configuring link speed and wake 
function. 

 

Содержание MECS-6110

Страница 1: ...MECS 6110 6111 1U Edge Server with Intel Xeon D Processor User s Manual Manual Rev Rev 1 2 Revision Date February 21 2022 Part No 50M 00037 1020...

Страница 2: ...its social responsibility to global environmental preservation through compliance with the European Union s Restriction of Hazardous Substances RoHS directive and Waste Electrical and Electronic Equip...

Страница 3: ...composants la perte de donn es et ou la corruption de programme lors de l ex cution d une t che sp cifique AVERTISSEMENT Information to prevent minor physical injury component damage data loss and or...

Страница 4: ...rom the Rack 28 3 7 Connecting the System to Ground 29 3 8 System Power Cable Installation 30 3 9 Login to the BMC via Console Port 31 3 10 Login to the BMC via Network 33 3 11 BMC eth0 Default and St...

Страница 5: ...R I210 Gigabit Network Connection 64 5 3 10 Sub Menu Intel R Ethernet Connection X722 for 10GbE 65 5 4 Chipset Menu 66 5 4 1 System Agent SA Configuration 66 5 4 2 Sub Menu CPU Configuration 67 5 4 3...

Страница 6: ...uting infrastructure deployment The main features of the MECS 6110 as follows 1x Intel Xeon D 2100 family processor 4x DDR4 2666 RDIMM ECC REG up to 256GB 2x 2 5 SATA bays only for MECS 6110 and 2x M...

Страница 7: ...3 0 x1 Flexible IO 10 not used Flexible IO 11 Flexible IO 14 15 PE2 15 0 miniSAS HD U 2 PCIe 3 0 x8 SATA3 0 x8 Flexible IO 18 25 Flexible IO 16 17 UART5 BMC UART1 Host Console UART2 UART3 1PPS 4x 1PPS...

Страница 8: ...CS 6111 Front Panel LEDs SATA Bay x2 Console Port RJ45 x2 SFP x4 USB x2 Reset Button PCIe Expansion Slots x2 LEDs 1PPS TOD Port Power Button Redundant Power Supply LEDs Console Port RJ45 x2 SFP x4 USB...

Страница 9: ...9 MECS 6110 1 3 3 MECS 6110 Rear Panel 1 3 4 MECS 6111 Rear Panel Redundant Power Supply Fans VGA Grounding Stud Fans VGA Grounding Stud...

Страница 10: ...CS 6110 Internal Layout See 3 1 Removing the Chassis Cover on page 15 for instructions on removing the cover DDR4 DIMM x4 PSU Fans M 2 SATA Slot PCIe x16 Gen3 FHFL x2 SATA Drive Bay x2 M 2 SATA Slot P...

Страница 11: ...1 3 6 MECS 6111 Internal Layout See 3 1 Removing the Chassis Cover on page 15 for instructions on removing the cover DDR4 DIMM x4 Fans M 2 SATA Slot PCIe x16 Gen3 FHFL x2 PSU M 2 SATA Slot PCIe 12V P...

Страница 12: ...12 MECS 6110 1 4 Mechanical Dimensions Units mm...

Страница 13: ...hput for data plane packet processing Interfaces Expansion SKU dependent Option 1 2x PCIe x16 Gen3 single slot FHFL interfaces passive cooling up to 110W each Option 2 1x PCIe x16 Gen3 dual slot FHFL...

Страница 14: ...ting temp 5 C 55 C Storage temp 40 C to 70 C Note Not including SATA drives and PCIe cards Humidity Operating 5 to 95 non condensing Storage 5 to 95 non condensing Operating half sine 2G 11ms pulse 10...

Страница 15: ...s 2 Press down on the two depressions with your thumbs and slide the cover towards the rear of the chassis and remove the cover To reinstall the cover slide it towards the front of the chassis then ti...

Страница 16: ...limitations on installing memory modules in this device Each slot can accept a memory module up to 64GB All installation procedures are restricted to skilled personnel Toutes les proc dures d install...

Страница 17: ...pecific installation procedures for your cards please contact your ADLINK representative 1 Remove the two screws from the front panel as shown 2 Remove the bracket securing the PCIe bracket blanking p...

Страница 18: ...blanking plates 4 Loosen the two screws to remove the internal PCIe bracket used to secure the PCIe cards inside the chassis The diagram shows the position of the bracket for full length cards Bracke...

Страница 19: ...the lower PCIe expansion card Align the tab on the bracket with the opening on the rear I O panel A and insert the PCIe connector into the slot on the riser card B Make sure the connector is fully ins...

Страница 20: ...20 MECS 6110 6 Then install the upper PCIe expansion card if required...

Страница 21: ...21 MECS 6110 7 Replace the internal PCIe bracket insert the PCIe cards into the slots arrows and tighten the two screws circles to secure the cards inside the chassis...

Страница 22: ...22 MECS 6110 8 Replace the bracket to secure the PCIe I O brackets to the chassis 9 Secure the bracket with two screws as shown...

Страница 23: ...uded The pin definitions of the connectors and cables are described below 4 pin ATX type 12V Power Connector Pinout Pin Signal Color 1 GND black 2 GND black 3 P12V yellow 4 P12V yellow Adapter Cable C...

Страница 24: ...24 MECS 6110 3 5 Rails Assembly and Rack Installation...

Страница 25: ...25 MECS 6110...

Страница 26: ...26 MECS 6110...

Страница 27: ...27 MECS 6110...

Страница 28: ...28 MECS 6110 3 6 Remove the Chassis from the Rack...

Страница 29: ...g IEC power cord Please use the power cord provided with the system for your region A grounding stud M4 size is provided on the rear of the chassis for additional connection to ground DC Version A gro...

Страница 30: ...30 MECS 6110 3 8 System Power Cable Installation AC PSU Input 3 prong IEC power cord DC PSU Input DC Negative connect to 36V to 72V DC Positive connect to RTN...

Страница 31: ...e 4 8 Board Layout on page 49 Console Port Mode CN15 CN16 default 1 2 1 2 BMC 2 3 2 3 Step 2 Use the included RJ 45 to DB 9 console port adapter cable to connect the PC to the RJ 45 console port of th...

Страница 32: ...serial port console tool such as PuTTY choose the higher COM port it may be different depending on the computer then set the baud rate to 115200 Step 3 Input the user name sysadmin and password superu...

Страница 33: ...1 Use a LAN cable to connect either eth0 or eth1 of the MECS 6110 to the PC Step 2 Open a serial port console tool such as PuTTY enter the IP address and open a connection to the BMC login using seri...

Страница 34: ...34 MECS 6110 Step 3 Input the user name sysadmin and password superuser to login to the system...

Страница 35: ...he IP source to static ipmitool lan set 1 ipsrc static Set the IP address ipmitool lan set 1 ipaddr xxx xxx xxx xxx Set the netmask address ipmitool lan set 1 netmask xxx xxx xxx xxx Set the gateway a...

Страница 36: ...pmitool lan set 8 ipsrc static Set the IP address ipmitool lan set 8 ipaddr xxx xxx xxx xxx Set the netmask address ipmitool lan set 8 netmask xxx xxx xxx xxx Set the gateway address ipmitool lan set...

Страница 37: ...install expect 3 Copy the BMC FW package BMC_MECS 6110_Release_Vx xx to the debug PC Upgrade Procedure 1 Check the IP of the BMC of MECS 6110 Power on the MECS 6110 boot the BMC to Linux username sysa...

Страница 38: ...ng BIOS via Host with BIOS Tool 1 Boot Login to Shell 2 Update the BIOS over host with the following commands Example AfuEfix64 BIOS ROM p b n x to update BIOS without ME AfuExfi64 BIOS BIN p b n x me...

Страница 39: ...2 Install expect to your debug PC ex sudo apt get install expect 3 Copy the BMC FW package BMC_MECS 6110_Release_Vx xx to the debug PC Upgrade Procedure 1 Check the IP of the BMC of MECS 6110 Power o...

Страница 40: ...PLEASE DO NOT USE THIS FLASH TOOL FROM THE REDIRECTION CONSOLE Uploading Firmware Image 100 done Skipping boot Module Flashing conf Module Flashing Firmware Image 100 done Verifying Firmware Image 100...

Страница 41: ...is enabled the screen below will not display but pressing the Delete or ESC key will still allow you to enter the BIOS setup screen 3 After pressing the Delete or ESC key the main BIOS setup menu wil...

Страница 42: ...r and 4 7 User LED Commands on page 47 UID Button and LED blue The UID button indicator is used to conveniently locate the server The LED can be turned off or on manually by pressing the UID button or...

Страница 43: ...onnector Their behavior is as follows The LED1 Speed indicates the speed of the LAN connection LED1 Speed 10 Mbps Off 100 Mbps Green 1000 Mbps Orange The LED2 Link Activity indicates that a link has b...

Страница 44: ...or Link up Yellow steady Link Status Link down Off Active Green blinking Link Activity Not active Off Pin Signal Name 1 GND 2 TX_FAULT 3 TX_DSBL 4 SDA 5 SCL 6 MOD_ABS 7 RS0 8 RX_ OS 9 RS1 10 GND 11 GN...

Страница 45: ...5V U2 USB2_N U3 USB2_P U4 GND U5 SSRX_N U6 SSRX_P U7 GND U8 SSTX_N U9 SSTX_P U10 5V U11 USB2_N U12 USB2_P U13 GND U14 SSRX_N U15 SSRX_P U16 GND U17 SSTX_N U18 SSTX_P The MECS 6110 comes with an RJ 45...

Страница 46: ...46 MECS 6110 4 5 1PPS TOD Connector Pin Signal Upper Signal Lower 1 NC NC 2 NC NC 3 1PPS_TXD_N 1PPS_RXD_N 4 GND GND 5 GND GND 6 1PPS_TXD_P 1PPS_RXD_P 7 TOD_TXD_N TOD_RXD_N 8 TOD_TXD_P TOD_RXD_P 8 1...

Страница 47: ...ED red 04h LED1 green 05h LED2 red Other values reserved 5 LED Function 00h LED OFF override 01h 1Eh LED BLINKING override The off duration is specified by the value of this byte and the on duration i...

Страница 48: ...rst 5 LED ID 01h UID LED blue 02h USR LED yellow HDD shared 03h Alert LED red 04h LED1 green default blink 05h LED2 red Other values reserved 6 LED Function 00h LED OFF override 01h 1Eh LED BLINKING o...

Страница 49: ...LED2 DIMMD1 DIMME1 CN29 HBLED1 CN40 CN30 H11 CN33 H12 BAT_SKT1 CN42 CN_SAS1 CN9 H3 H23 H17 PCIE1 CN10 PCIE_1 CN50 CN49 H25 SATA1 M2_2 CN11 SATA2 CN12 VGA1 CN7 CN34 CN23 CN24 CN21 H14 CN25 CN26 CN41 BM...

Страница 50: ...Flash C DDR4 Socket 2 L Secondary BIOS SPI Flash D Debug Port Port 80 M OCP Connectors E BMC MECS 6110 LAN RJ 45 N PCIe x32 Connector F Console Port RJ 45 USB 3 0 O 1PPS TOD Ports G M 2 Slot P Clear...

Страница 51: ...IOS setup menu use the following Left Right The Left and Right Arrow keys allow you to select a setup screen For example Main screen Advanced screen Chipset screen and so on Up Down The Up and Down Ar...

Страница 52: ...ields are in black The BIOS setup fields currently not used are in grey The display only strings are in black Using brackets Editable menu options are marketed with squares and to distinguish them fro...

Страница 53: ...Options Description Project Name Info only It shows Project Name CPU Brand String Info only Intel R Core It shows what CPU is booting the system CPU Frequency Info only XXXX MHz It shows CPU s freque...

Страница 54: ...n Sub Menu For configuring Network Stack CSM Configuration Sub Menu For CSM configuration NVME Configuration Sub Menu For NVME devices OEM IPMI Settings Sub Menu For OEM IPMI settings iSCSI Configurat...

Страница 55: ...55 MECS 6110 5 3 1 Sub Menu Trusted Computing BIOS Item Options Description Security Device Disabled Enabled Enable or Disable security device such as TPM...

Страница 56: ...Enabled To enable or disable serial Port Device Settings Info only Show serial port IO address and IRQ source Change Settings Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7...

Страница 57: ...ection BIOS Item Options Description Console Redirection Enabled Disabled Enable or disable serial port console redirection function Console Redirection Settings Sub Menu For configuring serial port s...

Страница 58: ...if the num of 1 s in the data bits is even Odd parity bit is 0 if num of 1 s in the data bits is odd Mark parity bit is always 1 Space Parity bit is always 0 Mark and Space Parity do not allow for err...

Страница 59: ...s Description Above 4G Decoding Disabled Enabled To enable or disable decoded in above 4G address Spacd SR IOV Support Disabled Enabled Enable or disable Single Root IO virtualization support BME DMA...

Страница 60: ...60 MECS 6110 5 3 5 Sub Menu Network Stack Configuration BIOS Item Options Description Network Stack Disabled Enabled To enable or disable network stack...

Страница 61: ...OM of network controller UEFI will execute EFI driver and legacy will search option ROM of device to hook Storage UEFI Legacy Select the method of launch option ROM of storage controller UEFI will exe...

Страница 62: ...62 MECS 6110 5 3 7 Sub Menu NVMe Configuration...

Страница 63: ...Policy Do Nothing Reset Power Down Configure how the system should respond if the POST Watchdog Timer expires OS load Watchdog Timer Disabled Enabled Enable Disable OS Load watchdog timer OS load Watc...

Страница 64: ...system it will launch the onboard Ethernet I210 controller s UEFI driver The driver provides a setup page for configuring Ethernet parameters and shows information about Ethernet controller When the...

Страница 65: ...3 10 Sub Menu Intel R Ethernet Connection X722 for 10GbE BIOS Item Options Description Firware Image Properties As below View device firmware version NIC Configuration For configuring link speed and...

Страница 66: ...66 MECS 6110 5 4 Chipset Menu 5 4 1 System Agent SA Configuration...

Страница 67: ...OS Item Options Description CPU string Info only To show CPU info Hyper Threading ALL Disable Enable To enable or disable logical processor threads Intel Virtualization Technology Enable Disable To en...

Страница 68: ...o 800 1000 1066 1200 To select maximum memory frequency Attempt Fast Boot Auto Disable Enable To enable or disable skip memory reference code on warm boots Auto is Enable now Attempt Fast Cold Boot Au...

Страница 69: ...Options Description SocketX ChX DimmX Info only To show channel dimm spd info 5 4 3 2 Sub Menu Memory Timings Override BIOS Item Options Description XMP Profile Disable Enable To enable or disable Int...

Страница 70: ...70 MECS 6110 5 4 4 Sub Menu IIO Configuration...

Страница 71: ...16 Auto Selects PCIe port bifurcation for riser card upstream port auto is x16 IOU0 IIO PCIe Br2 X4x4x4x4 X4x4x8 X8x4x4 X8x8 X16 Auto Selects PCIe port bifurcation for riser card downstream port auto...

Страница 72: ...Port Auto is enable Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s Choose Link Speed Auto is Gen3 Override Max Link Width Auto X1 X2 X4 X8 X16 Override the max link width that was set by bi...

Страница 73: ...MECS 6110 5 4 5 Sub Menu Intel R VT for Directed I O vt d BIOS Item Options Description Intel VT for Directed I O VT d Disable Enable To enable or disable Intel Virtualization Technology for Directed...

Страница 74: ...74 MECS 6110 5 4 6 PCH IO Configuration 5 4 7 Sub Menu PCH Configuration...

Страница 75: ...em Options Description Serial IRQ Mode Quiet Continuous Configure Serial IRQ Mode Exrernal SSC Enable CK420 Disable Enable To enable or disable Spread Spectrum PCH state after G3 S0 S5 Leave power sta...

Страница 76: ...k Power Management Enable Disable To Enable Disable SALP sSATA Port X Info Only To show installed sata info Port X Enable Disable To enable or disable this sata port Hot Plug Enable Disable To enable...

Страница 77: ...77 MECS 6110 5 4 8 Sub Menu Server ME Information...

Страница 78: ...Password When pressing enter a menu will be popped up for creating new password When password installed press enter without inputting password it will clear password User Password Enter to set passwor...

Страница 79: ...Boot mode select Legacy UEFI Select boot mode Legacy UEFI Boot Option 1 9 1 Hard Disk 2 CD DVD 3 SD 4 USB Hard Disk 5 USB CD DVD 6 USB Key 7 USB Floppy 8 USB LAN 9 Network For boot priority setting XX...

Страница 80: ...em do reset to boot system Discard Changes and Reset Enter Discard all changed settings and let system do reset to boot system Save Changes Enter Save all changed settings Discard Changes Enter Discar...

Страница 81: ...Enabled Disabled To enable or disable wait for BMC 30s before sending Self Test command Time Zone UTC Offset Current Time Zone 0x7FFF Info only Enter UTC Offset in hours ox7FFF to consider BIOS time...

Страница 82: ...n every reset Choose options for erasing SEL When SEL is Full Do Nothing Erase immediately Choose options for reactions when SEL is full Log EFI Status Codes Disabled Both Error code Progress code Log...

Страница 83: ...og BIOS Item Options Description Log area usage 00 out of 20 logs Read only Log area usage numbers Erase Log No Yes on every reset Erase Log Options When log is Full Clear Log Do not log any more Sele...

Страница 84: ...cBmcNonDhcp Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Configure IPV6 support R...

Страница 85: ...Sub Menu BMC User Settings BIOS Item Options Description Add User Sub Menu Press Enter to Add a User Delete User Sub Menu Press Enter to Delete a User Change User Settings Sub Menu Press Enter to Cha...

Страница 86: ...Name User Password Enter to set password Enter BMC User Password User Access Disable Enable Enable Disable the BMC User s Access Channel No 0 15 Enter BMC Channel Number User Privilege Limit Reserved...

Страница 87: ...87 MECS 6110 5 8 4 2 Sub Menu Delete User BIOS Item Options Description User Name Enter to set user name Enter BMC User Name User Password Enter to set password Enter BMC User Password...

Страница 88: ...C User Name User Password Enter to set password Enter BMC User Password User Access Disable Enable Enable Disable the BMC User s Access Channel No 0 15 Enter BMC Channel Number User Privilege Limit Re...

Страница 89: ...or liquid sources Keep equipment away from high heat or high humidity Keep equipment properly ventilated do not block or cover ventilation openings Make sure to use recommended voltage and power sour...

Страница 90: ...alified service personnel or users familiar with restrictions applied to the location reasons therefor and any precautions required Only afforded by the use of a tool or lock and key or other means of...

Страница 91: ...emettre l alimentation 6 Pour viter un risque d lectrocution et pour viter d endommager l quipement loignez l quipement de l eau et de toute source liquide loignez l quipement de toute source de chale...

Страница 92: ...ntenance qualifi ou utilisateurs familiers avec les restrictions appliqu es l emplacement motifs et tout les pr cautions n cessaires et L acc s est uniquement assur e par l utilisation d un outil ou c...

Страница 93: ...Toll Free 1 800 966 5200 USA only Fax 1 408 600 1189 Email info adlinktech com ADLINK Technology China Co Ltd Address 300 201203 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 20120...

Отзывы: