3.15 BMC Firmware Update via Host with Yafuflash
The MECS-6110 supports a BMC Chassis Management firmware, IPMI v2.0 compliant.
To update the BMC firmware via host with Yafuflash, perform the following steps.
1. Login to the OS with root user permission.
2. Update the BMC over host using the commands below:
Example:
$ sudo ./Yafuflash
-
kcs rom.ima
YAFUFlash - Firmware Upgrade Utility (Version 4.117.7)
-------------------------------------------------
(C)Copyright 2016, American Megatrends Inc.
The Module root allocated size is different from the one in the Image
So,Type (Y/y) to do Full Firmware Upgrade or (N/n) to exit
Enter your Option : Y
**************************************************************************
WARNING!
FIRMWARE UPGRADE MUST NOT BE INTERRUPTED ONCE IT IS STARTED.
PLEASE DO NOT USE THIS FLASH TOOL FROM THE REDIRECTION CONSOLE.
**************************************************************************
Uploading Firmware Image : 100%... done
Skipping [boot] Module ....
Flashing [conf] Module ....
Flashing Firmware Image : 100%... done
Verifying Firmware Image : 100%... done
Flashing [root] Module ....
Flashing Firmware Image : 100%... done
Verifying Firmware Image : 100%... done
Flashing [osimage] Module ....
Flashing Firmware Image : 100%... done
Verifying Firmware Image : 100%... done
Flashing [www] Module ....
Flashing Firmware Image : 100%... done
Verifying Firmware Image : 100%... done
Flashing [testapps] Module ....
Flashing Firmware Image : 100%... done
Verifying Firmware Image : 100%... done
Flashing [ast2500e] Module ....
Flashing Firmware Image : 100%... done
Verifying Firmware Image : 100%... done
Resetting the firmware..........
-------------------------------------------------
Open IPMI Drivers
-------------------------------------------------
Loading Open IPMI Driver:ipmi_devintf
BMC is booting up, Please load ipmi_si Open IPMI Driver after the BMC
Boots up!!!!
Loading Open IPMI Driver:ipmi_msghandler
Содержание MECS-6110
Страница 12: ...12 MECS 6110 1 4 Mechanical Dimensions Units mm...
Страница 20: ...20 MECS 6110 6 Then install the upper PCIe expansion card if required...
Страница 24: ...24 MECS 6110 3 5 Rails Assembly and Rack Installation...
Страница 25: ...25 MECS 6110...
Страница 26: ...26 MECS 6110...
Страница 27: ...27 MECS 6110...
Страница 28: ...28 MECS 6110 3 6 Remove the Chassis from the Rack...
Страница 34: ...34 MECS 6110 Step 3 Input the user name sysadmin and password superuser to login to the system...
Страница 62: ...62 MECS 6110 5 3 7 Sub Menu NVMe Configuration...
Страница 66: ...66 MECS 6110 5 4 Chipset Menu 5 4 1 System Agent SA Configuration...
Страница 70: ...70 MECS 6110 5 4 4 Sub Menu IIO Configuration...
Страница 74: ...74 MECS 6110 5 4 6 PCH IO Configuration 5 4 7 Sub Menu PCH Configuration...
Страница 77: ...77 MECS 6110 5 4 8 Sub Menu Server ME Information...