![ADLINK Technology HSLink HSL-AI16 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/adlink-technology/hslink-hsl-ai16/hslink-hsl-ai16_user-manual_2852692035.webp)
NT DLL Programming
•
27
About the operation items in the “ADLink HSLink Master Utility”, they
will be described as following.
l
“Current Select Card ID” :
This utility will detect all HSLink master
cards (include PCI-7851 and PCI-7852) in this computer . The total
master cards will display in
the “Current Select Card ID”
item. User
can use it to specify the master card he want to operate.
l
“Current Select Set ID” :
When user have selected the master card,
then the
“Current Select Set ID”
item will show the set ID number. For
the PCI-7851 master card, the “Current Select Set ID” is “Set ID0”. For
the PCI-7852 master card, the “Current Select Set ID” is “Set ID0” or
“Set ID1”.
l
“Connect / Auto Scan” :
When user press this button, the utility will
connect the master card and slave I/O modules, then scan all the
slave I/O modules in the
“Current Select Set ID”
of the
“Current
Select Card ID”.
This utility will show all the slave I/O module’s
attribute(include the address and slave type) on the screen.
l
“Slaves Disconnect” :
When user press this button, the utility will
disconnect the master card and slave I/O modules.
l
“Monitor” :
When user press
“Connect / Auto Scan”
button, all slave
I/O modules in the
“Current Select Set ID”
of the
“Current Select
Card ID”
will display in the screen. Now user can press th e
“Monitor”
button to enter the
“HSLink System Monitor”
window