2.2.5 COM1/COM2
GEME offers two serial communications interface ports: COM 1 and COM 2.
IRQ and Address Setting
The IRQ and I/O address range are both assigned by BIOS. The table below
describes COM1/COM2 default settings:
COM Port
Mode
Bass address
IRQ
COM 1
RS-232
3F8h IRQ4
COM 2
RS-232
2F8h IRQ3
COM1/COM2 Pin Assignment
Pin
RS-232
1
DCD, Data carrier detect
2
RXD, Receive data
3
TXD, Transmit data
4
DTR, Data terminal ready
5 GND,
ground
6
DSR, Data set ready
7
RTS, Request to send
8
CTS, Clear to send
9
RI, Ring indicator
Note: COM2 can also support RS422 or RS485 (with Auto direction function) by
adjusting jumper. The customer has to request this feature while placing
the order.
COM 2
Pin no.
RS422
RS485
1 TX- D-
2 TX+ D+
3 RX+
--
4 RX-
--
5 GND GND