cExpress-BT2
BIOS Setup
59
7.3.12. Thermal
Feature
Options
Description
Thermal
Info only
CPU Temperature
Info only
Critical Trip Point
Disabled
85 C
95 C
This value controls the temperature of the ACPI Critical
Trip Point - the point at which the OS will shut the
system down.
Active Cooling Trip Point
Disabled
40 C
50 C
60 C
70 C
BMC Default
Active Cooling Trip Point.
Passive Trip Point
Disabled
90 C
80 C
This value controls the temperature of the ACPI Passive
Trip Point - the point at which the OS will begin throtting
the processor.
Passive TC1 Value
1
This value sets the TC1 value for the ACPI Passive
Cooling Formula. Range 1 - 16
Passive TC2 Value
5
This value value sets the TC2 value for the ACPI
Passive Cooling Formula. Range 1 - 16
Passive TSP Value
10
This item sets the TSP value for the ACPI Passive
Cooling Formula. It represents in tenths of a second
how often the OS will read the temperature when
passive cooling is enabled. Range 2 - 32
7.3.13. Miscellaneous
Feature
Options
Description
Miscellaneous
Info only
High Precision Timer
Enabled
Disabled
Enable or disable the High Precision Event Timer.
SCC Configuration
Submenu
Security
Info only
BIOS Security Configuration
Submenu
Trusted Computing
Submenu
Содержание COM Express cExpress-BT2
Страница 8: ...2 Introduction This page intentionally left blank...
Страница 42: ...36 Smart Embedded Management Agent SEMA This page intentionally left blank...
Страница 48: ...42 System Resources This page intentionally left blank...
Страница 80: ...74 BIOS Checkpoints Beep Codes This page intentionally left blank...