background image

cExpress-BT2 

 
BIOS Setup 

49 

7.3.  Advanced 

This menu contains the settings for most of the user interfaces in the system. 

7.3.1. 

CPU 

Feature  

Options  

Description  

CPU 

Infor only 

CPU Brand Name 

Info only 

Display CPU brand name 

CPU Signature 

Info only 

Display CPU signature 

Processor Family 

Info only 

Display processor family 

Microcode Patch 

Info only 

Display microcode patch 

Max CPU speed 

Info only 

Display max. CPU speed 

Min CPU speed 

Info only 

Display min. CPU speed 

Processor Cores 

Info only 

Display number of processor cores 

Intel HT Technology 

Info only 

Display Intel HT Technology support 

Intel VT-x Technology 

Info only 

Display Intel VT-x Technology support 

64-bit 

Info only 

Display 64-bit support  

L1 Data Cache 

Info only 

Display cache info 

L1 Code Cache 

Info only 

Display cache info 

L2 Cache 

Info only 

Display cache info 

L3 Cache 

Inf o only 

Display cache info 

Limit CPUID Maximum 

Disabled 

Enabled 

Disabled for Windows XP 

Execute Disabled Bit 

Disabled 

Enabled 

XD can prevent certain classes of malicious buffer 
overflow attacks when combined with a supporting OS 
(Windows Server 2003 SP1, Windows XP SP2, SuSE 
Linux 9.2, Red Hat Enterprise 3 Update 3.) 

Intel Virtualization Technology 

Disabled 

Enabled 

When enabled, a VMM can utilize the additional 
hardware capabilities provided by Vanderpool 
Technology. 

SB CRID 

Revision ID 

CRID 0 
CRID 1 
CRID 2 

Select the Revision ID (Revision ID, CRID 0, CRID 1, 
CRID 2) reflected in PCI config space 

CPU Processor Power Management 
(PPM) 

Info only 

EIST 

Disabled 

Enabled 

Enable/Disable Intel SpeedStep 

CPU C state Report 

Disabled 

Enabled 

Enable/Disable CPU C state report to OS 

CPU DTS 

Disabled 

Enabled 

Enabled/Disable digital thermal sensor 

Содержание COM Express cExpress-BT2

Страница 1: ...cExpress BT2 User s Manual COM Express Compact Size Type 2 Module with Intel Atom E3800 and Celeron Processor SoC Manual Rev 1 2 Revision Date April 7 2020 Part Number 50 1J052 1020...

Страница 2: ...orced measures to ensure that our products manufacturing processes components and raw materials have as little impact on the environment as possible When products are at their end of life our customer...

Страница 3: ...s 5 2 11 Operating Temperatures 5 2 12 Environmental 6 2 13 Specification Compliance 6 2 14 Operating Systems 6 2 15 Functional Diagram 7 2 16 Mechanical Dimensions 8 3 Pinouts and Signal Descriptions...

Страница 4: ...ap 41 6 6 PCI Interrupt Routing Map 41 7 BIOS Setup 43 7 1 Menu Structure 43 7 2 Main 44 7 3 Advanced 49 7 4 Boot 61 7 5 Security 63 7 6 Save Exit 64 8 BIOS Checkpoints Beep Codes 65 8 1 Status Code R...

Страница 5: ...Functional Block Diagram 7 Figure 2 cExpress BT2 Mechanical Drawing 8 Figure 3 cExpress BT2 Connector Switch and LED Locations 27 Figure 4 cExpress BT2 and the DB40 Debug Module 27 Figure 6 COM Expres...

Страница 6: ...Debug Connector Pin Definition 28 Table 3 cExpress BT2 LED Descriptions 29 Table 4 MIPI60 Debug Header Pin Definition 30 Table 5 Fan Connector Pin Definition 31 Table 7 SEMA Onboard Voltage Monitor 34...

Страница 7: ...cludes features such as OpenGL 3 1 DirectX 11 OpenCL 1 1 support for H 264 MPEG2 VC1 VP8 hardware decode Graphics outputs include VGA and dual channel 18 24 bit LVDS The cExpress BT2 is specifically d...

Страница 8: ...2 Introduction This page intentionally left blank...

Страница 9: ...4 Turbo 10W 4C 1333 Single dual or quad Out of Order Execution OOE processor cores Intel VT x Intel SSE4 1 and SSE4 2 Intel 64 architecture IA 32 bit PCLMULQDQ Instruction DRNG Intel Thermal Monitor T...

Страница 10: ...atures may vary between operating systems Display Types Dual channel 18 24 bit LVDS through eDP to LVDS bridge use DDI0 signal of SoC VGA supporting resolutions of up to 2560x1600x24bpp 60Hz 2 4 Audio...

Страница 11: ...TPM 1 2 2 10 Power Specifications Power Modes AT and ATX mode AT mode startup controlled by SEMA Board Controller Standard Voltage Input ATX 12V 5 5Vsb 5 or AT 12V 5 Wide Voltage Input ATX 5 20 V 5Vs...

Страница 12: ...7 MIL STD 202F Method 213B Table 213 I Condition A and Method 214A Table 214 I Condition D HALT Thermal Stress Vibration Stress Thermal Shock and Combined Test 2 13 Specification Compliance PICMG COM...

Страница 13: ...2 PCIe x1 Gen2 port 0 1 PCIe x1 Gen2 port 3 UART0 UART1 eMMC 8 16 32GB LM73 TPM Atmel AT97SC3204 GPIO PCA9535 SEMA BMC SMBus 4x GP0 GP I2 C SPI 0 BIOS LPC bus SPI 4x GPI SPI 1 BIOS DDC I2 C SPI SPI_CS...

Страница 14: ...8 Specifications 2 16 Mechanical Dimensions Top View Side View All tolerances 0 05 mm Other tolerances 0 2 mm All are dimensions shown in millimeters Figure 2 cExpress BT2 Mechanical Drawing...

Страница 15: ...0 B12 PWRBTN C12 IDE_D14 D12 IDE_IRQ A13 GBE0_MDI0 B13 SMB_CK C13 IDE_IORDY D13 IDE_A0 A14 GBE0_CTREF B14 SMB_DAT C14 IDE_IOR D14 IDE_A1 A15 SUS_S3 B15 SMB_ALERT C15 PCI_PME D15 IDE_A2 A16 SATA0_TX B1...

Страница 16: ...C54 TYPE0 D54 PEG_LANE_RV A55 PCIE_TX4 B55 PCIE_RX4 C55 PEG_RX1 D55 PEG_TX1 A56 PCIE_TX4 B56 PCIE_RX4 C56 PEG_RX1 D56 PEG_TX1 A57 GND B57 GPO2 C57 TYPE1 D57 TYPE2 A58 PCIE_TX3 B58 PCIE_RX3 C58 PEG_RX...

Страница 17: ...RX12 D92 PEG_TX12 A93 GPO0 B93 VGA_HSYNC C93 GND D93 GND A94 SPI_CLK B94 VGA_VSYNC C94 PEG_RX13 D94 PEG_TX13 A95 SPI_MOSI B95 VGA_I2C_CK C95 PEG_RX13 D95 PEG_TX13 A96 GND B96 VGA_I2C_DAT C96 GND D96 G...

Страница 18: ...O 5V Output 5V signal level I O 3 3V Bi directional signal 3 3V tolerant I O 5V Bi directional signal 5V tolerant I O 3 3Vsb Input 3 3V tolerant active in standby state P Power Input Output REF Refere...

Страница 19: ...log DAC output designed to drive a 37 5 Ohm equivalent load O Analog PD 150R shall also be terminated on the carrier with 150 resistor to ground close to VGA connector VGA_GRN B91 Green for monitor An...

Страница 20: ...LVDS_B2 LVDS_B2 LVDS_B3 LVDS_B3 B71 B72 B73 B74 B75 B76 B77 B78 LVDS Channel B differential pairs O LVDS LVDS_B_CK LVDS_B_CK B81 B82 LVDS Channel B differential clock O LVDS LVDS_VDD_EN A77 LVDS pane...

Страница 21: ...e requirements of the Module PHY and may be as low as 0V and as high as 3 3V The reference voltage output shall be current limited on the Module In the case in which the reference is shorted to ground...

Страница 22: ...IE_RX2 PCIE_RX2 B61 B62 PCI Express channel 2 Receive Input differential pair I PCIE Not supported PCIE_TX3 PCIE_TX3 A58 A59 PCI Express channel 3 Transmit Output differential pair O PCIE Not supporte...

Страница 23: ...48 B47 PCI ExpressCard reset O 3 3V 3 3 8 LPC bus Signal Pin Description I O PU PD Comment LPC_AD 0 3 B4 B7 LPC multiplexed address command and data bus I O 3 3V LPC_FRAME B3 LPC frame indicates the s...

Страница 24: ...B44 USB over current sense USB ports 0 and 1 A pull up for this line shall be present on the module An open drain driver from a USB current monitor on the carrier board may drive this line low I 3 3VS...

Страница 25: ...pport CS0 SPI_MISO A92 Data in to module from carrier board SPI BIOS flash I 3 3VSB SPI_MOSI A95 Data out from module to carrier board SPI BIOS flash O 3 3VSB SPI_CLK A94 Clock from module to carrier...

Страница 26: ...output I OD 3 3V PU 10k 3 3V 3 3 13 SMBus Signal Pin Description I O PU PD Comment SMB_CK B13 System Management Bus bidirectional clock line Power sourced through 5V standby rail and main power rails...

Страница 27: ...SER0_RX A99 General purpose serial port receiver TTL level input I CMOS Power rail tolerance 5V 12V SER1_TX A101 General purpose serial port transmitter TTL level output O CMOS Power rail tolerance 5V...

Страница 28: ...used to signal some other external power management event I 3 3VSB PU 10k 3 3VSB LID LID button Low active signal used by the ACPI operating system for a LID switch I OD 3 3VSB PU 10k 3 3VSB Emulated...

Страница 29: ...vice O 3 3V IDE_REQ D8 IDE Device DMA Request It is asserted by the IDE device to request a data transfer I 3 3V IDE_ACK D10 IDE Device DMA Acknowledge O 3 3V IDE_CS1 D16 IDE Device Chip Select for 1F...

Страница 30: ...PCI_C BE2 PCI_C BE3 D26 C33 C38 C44 PCI bus byte enable lines active low I O 3 3V PCI_DEVSEL C36 PCI bus Device Select active low I O 3 3V PU 8k2 3 3V PCI_FRAME D36 PCI bus Frame control line active...

Страница 31: ...PCI_IRQC PCI_IRQD C49 C50 D46 D47 PCI interrupt request lines I 3 3V PU 8k2 3 3V PCI_CLK D50 PCI 33MHz clock output O 3 3V 3 4 3 Module Type Definition Signal Pin Description I O Comment TYPE0 TYPE1 T...

Страница 32: ...5 20V All available VCC_12V pins on the connector s shall be used P 5 20V GND C1 C11 C21 C31 C41 C51 C60 C70 C76 C80 C84 C87 C90 C93 C96 C100 C103 C110 D1 D11 D21 D31 D41 D51 D60 D67 D70 D76 D80 D84...

Страница 33: ...cluded in the PICMG standard specification 4 1 Connector Switch and LED Locations CD AB FAN LED1 4 pin FAN 40 pin Debug Connector BIOS Defaults RESET Switch LED2 LED3 XDP 26 pin to CPU Figure 3 cExpre...

Страница 34: ...LPC Bus 3V3_LPC System power 3 3V provide from COM module 28 OCD0B Include a jumper to connect OCD0A via 1K0 pull up to 3 3V_BMC 9 GND 29 Test points PWRBTN 10 BIOS_DIS0 30 SYS_RESET 11 RST 31 CB_RES...

Страница 35: ...1 4 Exception Codes LED2 Green Power Source 3Vcc S0 LED ON S3 S4 S5 LED OFF ECO mode LED OFF LED3 Red BMC output and same signal as WDT B27 on BtB connector Module power up LED OFF Watchdog counting L...

Страница 36: ...N_A0 TAP_PREQ I O SoC 2 OBSFN_A1 TAP_PRDY I O SoC 3 GND GND NA 4 OBSDATA_A 0 DBG 0 I O SoC 5 OBSDATA_ A 1 DBG 1 I O SoC 6 GND GND NA 7 OBSDATA_ A 2 DBG 2 I O SoC 8 OBSDATA_A 3 DBG 3 I O SoC 9 GND GND...

Страница 37: ...s BT2 Module Interfaces 31 4 5 Fan Connector Connector Type JVE 24W1125A 04M00 Pin Orientation 1 2 3 4 Pin Assignment Name Signal 1 FAN_PWMOUT 2 FAN_TACHIN 3 Ground 4 5V Table 5 Fan Connector Pin Defi...

Страница 38: ...rm the following steps 1 Shut down the system 2 Press the BIOS Setup Defaults RESET Button continuously and boot up the system You can release the button when the BIOS prompt screen appears 3 The BIOS...

Страница 39: ...he number of boot attempts Watchdog Timer Set Reset Disable Watchdog Timer Features auto reload at power up System Restart Cause Power loss BIOS Fail Watchdog Internal Reset External Reset Fail safe B...

Страница 40: ...Table 6 SEMA Onboard Voltage Monitor 5 1 2 Main Current The BMC of the cExpress BT2 implements a current monitor The current can be read by calling the SEMA function Get Main Current The function ret...

Страница 41: ...ded or supported Exception Code Error Message 0 NOERROR 2 NO_SUSCLK 3 NO_SLP_S5 4 NO_SLP_S4 5 NO_SLP_S3 6 BIOS_FAIL 7 RESET_FAIL 8 POWER_FAIL 9 LOW_VIN 10 VCORE 11 VGFX 12 V1P05S 13 VMEM 14 V1P0A 15 V...

Страница 42: ...36 Smart Embedded Management Agent SEMA This page intentionally left blank...

Страница 43: ...0h FFFFFFFFh High BIOS 0K 1MB 1MB DOS DRAM 6 2 I O Map Hex Range Device 20h 21h 24h 25h 28h 29h 2Ch 2Dh 30h 31h 34h 5h 38h 39h 3Ch 3Dh 8259 Master 40h 43h 50h 53h 8254s 60h 64h PS2 Control 61h 63h 65h...

Страница 44: ...1 5 Parallel Port LPT IRQ5 via SERIRQ PIRQ Note 1 6 Generic IRQ6 via SERIRQ PIRQ Note 1 7 Generic IRQ7 via SERIRQ PIRQ Note 1 8 Real time clock N A No 9 Generic IRQ9 via SERIRQ PIRQ Note 1 10 Generic...

Страница 45: ...A Note 1 11 N A N A Note 1 12 PS 2 Mouse IRQ12 via SERIRQ PIRQ Note 1 13 N A N A Note 1 14 N A N A Note 1 15 N A N A Note 1 16 N A PCIE Port 1 2 3 4 eMMC IGD PCI Slot 1 2 3 4 Note 1 17 N A PCIE Port...

Страница 46: ...18h 00h Internal Serial IO SIO DMA 00h 18h 01h Internal Serial IO SIO I2C Port 1 00h 18h 02h Internal Serial IO SIO I2C Port 2 00h 1Ah 00h Internal Trusted Execution Engine 00h 1Bh 00h Internal HD Aud...

Страница 47: ...TD 19 INT Line SD Host 2 SD Card SATA Controller Texas Instruments PCIe to PCI Bridge xHCI Host Low Power Audio Engine TXE HDA Int0 INTE 20 INTF 21 INTF 21 INTG 22 Int1 Int2 INTC 18 INTC 18 Int3 INTD...

Страница 48: ...42 System Resources This page intentionally left blank...

Страница 49: ...and the function of each setting is described in the right hand column of the respective table Main Advanced Boot Security Save Exit System Information Processor Information VGA Firmware Version Memor...

Страница 50: ...escription CPU Brand String Info only Display CPU brand name Max CPU Speed Info only Display CPU frequency CPU Signature Info only Display CPU ID Number of Processors Info only Display number of proce...

Страница 51: ...isplay SMC serial number Manufacturing Date Read only Display SMC manufacturing date Last Repair Date Read only Display SMC last repair date MAC ID Read only Display SMC MAC ID SEMA Features Read only...

Страница 52: ...ime Read only The returned value specifies the total time in minutes the system is running in S0 state Current Runtime Read only The returned value specifies the time in seconds the system is running...

Страница 53: ...Feature Options Description LVDS Backlight Info only LVDS Backlight Bright 255 The value range starts at 0 and ends at 255 7 2 6 8 System Management Smart Fan Feature Options Description Smart Fan Inf...

Страница 54: ...Options Description System Date Day of Week MM DD YYYY Requires the alpha numeric entry of the day of the week day of the month calendar month and all 4 digits of the year indicating the century and...

Страница 55: ...he info L1 Code Cache Info only Display cache info L2 Cache Info only Display cache info L3 Cache Inf o only Display cache info Limit CPUID Maximum Disabled Enabled Disabled for Windows XP Execute Dis...

Страница 56: ...Device IGD when selected as the primary display Disabled Always disable IGD Aperture Size 256MB Select the aperture size DVMT Pre Allocated 64M Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size...

Страница 57: ...t BIST on the integrated display panel 7 3 4 SATA Feature Options Description SATA Info only SATA Controller s Enabled Disabled Enable Disable Serial ATA SATA Mode Selection IDE Mode AHCI Mode Select...

Страница 58: ...without EHCI hand off support The EHCI ownership change should be claimed by the EHCI OS driver USB Mass Storage Driver Support Enabled Disabled Enable Disable USB mass storage driver support Chipset...

Страница 59: ...abled Enable Disable UEFI network stack LAN Controller Enabled Disabled Enable Disable LAN controller 7 3 7 PCI and PCIe Feature Options Description PCI and PCIe Info only PCI Common Settings Info onl...

Страница 60: ...Auto BIOS auto configure Disabled Disables ASPM Extended Synch Disabled Enabled If enabled allows generation of Extended Synchronization patterns Link Training Retry Disable 2 3 5 Defines number of re...

Страница 61: ...sabled Enabled Enable or disable PCI Express Device Fatal Error Reporting NFER Disabled Enabled Enable or disable PCI Express Device Non Fatal Error Reporting CER Disabled Enabled Enable or disable PC...

Страница 62: ...l Port 2 Configuration Serial Port Device Settings Change Settings Enabled Disabled IO 2F8h IRQ 3 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7...

Страница 63: ...n of the Azalia device Disabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally enabled Auto Azalia will be enabled if present disabled otherwise Azalia Docking Support...

Страница 64: ...ct number of stop bits Flow Control None Hardware RTS CTS Select flow control VT UTF8 Combo Key Support Disabled Enable Enable VT UTF8 combination key support for ANSI VT100 terminals Recorder Mode Di...

Страница 65: ...in throtting the processor Passive TC1 Value 1 This value sets the TC1 value for the ACPI Passive Cooling Formula Range 1 16 Passive TC2 Value 5 This value value sets the TC2 value for the ACPI Passiv...

Страница 66: ...abled Disabled SCC SD card support enable disable SDR25 Support for SDCard Enabled Disabled Disable Enable SDR25 capability in SD Card controller DDR50 Support for SDCard Enabled Disabled Disable Enab...

Страница 67: ...les Quiet Boot option Fast Boot Disabled Enabled Enables or disables boot with initialization of a minimal set of devices required to launch active boot option Has no effect on BBS boot options WIN8 S...

Страница 68: ...mmediate Postponed BIOS reaction on INT19 trapping by Option ROM Immediate execute the trap right away Postponed execute the trap during legacy boot Boot option filter UEFI and Legacy Legacy only UEFI...

Страница 69: ...Boot settings 7 5 1 1 Security Secure Boot Menu Feature Options Description System Mode Setup Secure Boot Info only Secure Boot Disabled Enabled Secure Boot can be enabled if 1 System running in User...

Страница 70: ...rd Changes and Reset Yes No Reset system setup without saving any changes Save Options Info only Save Changes Yes No Save Changes done so far to any of the setup options Discard Changes Yes No Discard...

Страница 71: ...by the Intel Platform Innovation Framework for EFI the Framework The Framework refers the following boot phases which may apply to various status code checkpoint descriptions Security SEC initial low...

Страница 72: ...overy errors PEI 8 2 Standard Status Codes 8 2 1 SEC Phase Status Code Description 0x00 Not used Progress Codes 0x01 Power on Reset type detection soft hard 0x02 AP initialization before microcode loa...

Страница 73: ...th Bridge initialization North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre memory South Bridge initialization South Bridge module specific 0x1B Pre memory So...

Страница 74: ...ge module specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE IPL is started PEI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory...

Страница 75: ...ocess started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9...

Страница 76: ...ecific 0x6E North Bridge DXE initialization North Bridge module specific 0x6F North Bridge DXE initialization North Bridge module specific 0x70 South Bridge DXE initialization is started 0x71 South Br...

Страница 77: ...is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0xA8 Setup Verifying Password 0xA9 Start of Setup 0xAA Reserved for ASL see ASL Status Codes section below 0xAB Setup Input Wait 0xAC Rese...

Страница 78: ...ices are found 0xD7 No Console Input Devices are found 0xD8 Invalid password 0xD9 Error loading Boot Option LoadImage returned error 0xDA Boot Option is failed StartImage returned error 0xDB Flash upd...

Страница 79: ...System is waking up from the S3 sleep state 0x40 System is waking up from the S4 sleep state 0xAC System has transitioned into ACPI mode Interrupt controller is in PIC mode 0xAA System has transitione...

Страница 80: ...74 BIOS Checkpoints Beep Codes This page intentionally left blank...

Страница 81: ...to board connector with 0 5mm for a stacking height of 5 mm This connector can be used with 5 mm through hole standoffs SMT type Tyco 3 6318491 6 Foxconn QT002206 4141 3H 220 pin board to board conne...

Страница 82: ...with all COM Express modules 9 2 2 Heat Sinks A heat sink can be used as a thermal solution for a specific COM Express module and can have a fan or be fanless depending on the thermal requirements 9 2...

Страница 83: ...asten the heatsink to the module Step 4 Place the COM Express module and heatsink assembly onto the connectors on the carrier board as shown Then press down on the module until it is firmly seated on...

Страница 84: ...78 Mechanical Information Step 6 If you are installing a heatsink with a fan plug the fan connector into the carrier board as shown...

Страница 85: ...Module 2 mm M2 5 18 mm with spring washer 2 mm heatspreader with 9 mm through hole standoffs 5 mm threaded standoff DIP Carrier Board 2 mm COM Express Module 2 mm M2 5 18 mm with spring washer 2 mm h...

Страница 86: ...ffs are DIP type and through hole standoffs are SMT type Other types not listed are available upon request 5mm through hole standoff SMT type P N 33 72000 0050 5mm threaded standoff DIP type P N 33 72...

Страница 87: ...bles To avoid electrical shock and or damage to equipment Keep equipment away from water or liquid sources Keep equipment away from high heat or high humidity Keep equipment properly ventilated do not...

Страница 88: ...8 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd Address 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 20120...

Отзывы: