Low-Level Programming
•
17
MSB
LSB
Step1
Step2
D/A Converter
BASE+1 or BASE+3
BASE+0 or BASE+2
3.3 Converted Data Representation
Two analog output range alternatives are provided by the ACL-6128 :
Unipolar and Bipolar. The numbering of the converted data with have
different presentation for different output range.
3.3.1 Unipolar Numbering
0
4095
0000 0000 0000
1111 1111 1111
2048
1000 0000 0000
V.OUT = -Vref *
( 0/4095)
V.OUT = -Vref *
( 2048/4095)
V.OUT = -Vref *
( 4095/4095)
Example:
Converted Data =2047
Binary Code
=0111 1111 1111
Vref
=-5V
V.OUT
=-(-5 V) * ( 2047/ 4095) = 2.499 V
3.3.2 Bipolar Numbering
-2048
2047
0000 0000 0000
1111 1111 1111
0
1000 0000 0000
V.OUT = -Vref * ( -2048/2047)
V.OUT = -Vref *
(0/2047)
= 0V
V.OUT = -Vref * ( 2047/2047
)
Содержание ACL -6128
Страница 1: ...N u D A Q A C L 6 1 2 8 2 Channel Isolated 12 bit Analog Output Card U s e r s G u i d e...