Page 13
Heating System (cont.)
Do not replace the heating oil or any of the oil roller parts yourself
without consulting our engineers. Parts must be provided and approved
by A. Adkins and Sons Limited
3.8
Oil Drum Temperature Measurement
Testing of the Oil Drum
for temperature consistency or fault condition
should only be undertaken after consulting A. Adkins and Sons, and then
only using a wired Digital Thermometer
(*please see note below).
*Please Note:
The Digital Thermometer with external probe
is suitable for
surface, air and immersion/penetration measurement, which is
required for all Adkins heat presses.
Laser Thermometers only measure air surfaces
which can be
misleading due to currents of hot air floating on the surface of
the Oil Drum.
3.9
General Maintenance
The following checks should be carried out at regular intervals by a
qualified and competent person:-
•
Pneumatic system for air leaks
•
Pneumatic system for lubrication
•
Electrical connections
•
Belt tension and condition
•
Mechanical moving parts
Any enquiries to: