Adjust-A-Sink® E140 System by Accessible Systems Inc. | Minneapolis, MN | 612-238-4600 | www.adjustasink.com
8 of 25
3E.
Install the T1514 telescoping drain to
the end of the drain pipe support bracket
with two hose clamps provided.
With the shampoo bowl still at its
highest position extend the Telescoping
drain to the basket strainer. Connect the
slip joint nut to the basket strainer; make
sure to use the vinyl or rubber slip
joint gasket at the joint. Adjust the Drain
Clamp Bracket so that the Telescoping
Drain unit is plumb to the floor and hand
tighten the two 5/16” bolts holding the
bracket together.
NOTE: It is critical to the
proper operation of the
telescopic drain that the bowl
strainer basket is level, front to
back and side to side, and the
telescopic drain is installed
perpendicular to the floor – any
deviation to this will cause
premature wear and possible
failure of the drain system.
3F.
With the sink in its highest position,
pull down on the base of the telescoping
drain so it is fully extended. Using tape, a
marker or other means, mark along the
top of the hose clamp. Tighten one hose
clamp enough so the drain will not slide
for the next step.
Pull down -
Mark above
hose clamps