2D.
Install two 5/16” fasteners of
appropriate type and length through
the bottom row of mounting holes.
2E.
Unwrap the AC power cord as
needed and plug in to the intended
receptacle.
Press the switches on the upper
right of the lift unit and verify the
vertical travel and movement of the
slide section before continuing with
the installation.
Secure any excess supply cord so it
will not interfere with the slide
sections when in use.
TROUBLESHOOTING:
1. The linear actuator has built-it limit switches, so if it is at the end of travel, it will not move or make
any noise, try the reverse direction switch.
2. The linear actuator has a safety mechanism, so it only pushes the lift up, gravity pulls the lift down.
The slides on a new lift may be tight until break in, and the lift may not drop at this step of the
installation. The unit will drop with the full weight of the assembly and sink installed. You can
push down on the lift to get it back to the bottom position.