Adjust-A-Sink® E140 System by Accessible Systems Inc. | Minneapolis, MN | 612-238-4600 | www.adjustasink.com
12 of 25
The hoses should flex and loop up on the left
side of the bowl without snagging at the
lowermost position.
OPTION
: If you are installing a mixing valve,
attach the valve to the Drain Support Bracket
with 8-32 screws and spacers provided.
Connect the flexible supply lines directly to the
mixing valve.
3M. FINAL TESTING / LEAK TESTING PROCEDURE
Turn on the faucet and let run for 3-5 minutes at both the highest and lowest height positions.
Check all assembled plumbing joints to verify seals. Take appropriate action to address any leaks.
The telescopic drains are pressure tested per ASME standards prior to shipment–they should not
leak if installed properly.
Supply hoses
loop in lowest
position
4 port
mixing
valve