ADJ WiFlY EXR HEX PAR Скачать руководство пользователя страница 5

ADJ Products, LLC  -  www.adj.com  - WiFly EXR HEX Par User Manual Page 9

ADJ Products, LLC  -  www.adj.com  - WiFly EXR HEX Par User Manual Page 8

  WiFly EXR HEX Par                                                  Set Up

P

ower Supply:

 The ADJ WiFly EXR HEX Par contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The WiFly EXR HEX Par can be controlled via DMX-512 protocol. The 

WiFly EXR HEX Par has 5 DMX channel modes. The DMX address is set 

on the back panel of the WiFly EXR HEX Par. Your unit and your DMX 

controller require a standard 3-pin XLR connec-

tor for data input and data output (Figure 1). We 

recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all pro lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

 WiFly EXR HEX Par 

                                           Set Up

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

Figure 1

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Содержание WiFlY EXR HEX PAR

Страница 1: ...t names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and...

Страница 2: ...llation WiFly EXR HEX Par Introduction ADJ Products LLC www adj com WiFly EXR HEX Par User Manual Page 2 Unpacking Thank you for purchasing the WiFly EXR HEX Par by ADJ Products LLC Every WiFly EXR HE...

Страница 3: ...e fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The applianc...

Страница 4: ...acement please contact ADJ customer support 800 322 6337 3 7 Do Not use a damaged Battery The battery could be damaged during shipping caused by shock Should the battery be found damaged including dam...

Страница 5: ...the cable Also remember that DMX cable must be daisy chained and cannot be split WiFly EXR HEX Par Set Up Special Note Line Termination When longer runs of cable are used you may need to use a termin...

Страница 6: ...you are in Red dimming mode Press WiFly EXR HEX Par Operating Instructions Operating Power There are two ways to supply power to this unit battery power or AC power AC Power To run the unit using AC p...

Страница 7: ...SET UP button until SP XX is displayed When this is displayed you can adjust the running speed of your Auto Mode Use the UP or DOWN button to adjust the speed between SP 01 slowest and SP 16 fastest...

Страница 8: ...press the MODE button until rCXX is dis played XX represents a number between 00 14 2 Press the UP or DOWN buttons to either activate the remote func tion On or deactivate it Off DMX State This mode...

Страница 9: ...open line of sight NOTE The ADJ RFC control must be set to OFF to use this func tion See page 14 to turn OFF ADJ RFC 1 Turn on the WiFly function using the WiFly On Off switch 2 Follow the instruction...

Страница 10: ...des you can use the and buttons to find scroll through the 16 different programs You can control the speed of each of the modes by pressing the SPEED button and using the and buttons PROGRAM SELECTION...

Страница 11: ...LED ON WiFly EXR HEX Par 8 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 AMBER 0 255 0 100 6 UV 0 255 0 100 7 MASTER DIMMER 0 255 0...

Страница 12: ...CTIVE 4 64 79 SOUND ACTIVE 5 80 95 SOUND ACTIVE 6 96 111 SOUND ACTIVE 7 112 127 SOUND ACTIVE 8 128 143 SOUND ACTIVE 9 144 159 SOUND ACTIVE 10 160 175 SOUND ACTIVE 11 176 191 SOUND ACTIVE 12 192 207 SO...

Страница 13: ...D ACTIVE 0 255 COLOR MACRO MODE See Color Macros Chart on page 27 WiFly EXR HEX Par 12 Channel Mode Channel Value Function 10 COLOR MACROS PROGRAMS SOUND ACTIVE COLOR CHANGE PROGRAMS 0 15 COLOR CHANGE...

Страница 14: ...TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT TO UNIT SETTING WiFly EXR HEX Par 12 Channel Mode 0 3 Off 64 67 B W 128 131 G B W 192 195 R B W A 4 7 Red 68 71 B A 132 135 G B A 196 199 R B W UV...

Страница 15: ...battery life is below 30 the digital display will flash NOTE After 20 seconds of inactivity the display will revert back to the battery life display Battery Recharge To recharge the battery plug the...

Страница 16: ...product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of mercha...

Страница 17: ...ADJ Products LLC www adj com WiFly EXR HEX Par User Manual Page 32 ADJ Products LLC www adj com WiFly EXR HEX Par User Manual Page 33 WiFly EXR HEX Par Notes WiFly EXR HEX Par Notes...

Страница 18: ...oltage when it is plugged into the power source WiFly EXR HEX Par Specifications Model WiFly EXR HEX Par Voltage 100V 240V 50 60Hz Battery Charge Time 5 Hours With Load Switch Off Battery Life 6 Hours...

Отзывы: