ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 10
UV Flood 36 3 Channel Mode
Channel Value
Function
1 DIMMER
0 - 255 0% - 100%
2 STROBING
0 - 31 LED OFF
32 - 63 LED ON
64 - 95 STROBING SLOW - FAST
96 - 127 LED ON
128 - 159 PULSE STROBE SLOW - FAST
160 - 191 LED ON
192 - 223 RANDOM STROBE SLOW - FAST
224 - 255 SOUND ACTIVE STROBING
3 DIMMER CURVES
0 - 20 STANDARD
21 - 40 STAGE
41 - 60 TV
61 - 80 ARCHTECTURAL
81 - 100 THEATRE
101 - 255 DEFAULT TO UNIT CURRENT SETTING
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 11
UV Flood 36 Dimmer Curve Chart
(Fade Time)
(Fade Time)
Ramp Effect
Standard
Stage
TV
Architectural
Theatre
UV Flood 36 1 Channel Mode
Channel Value
Function
1 DIMMER
0 - 255 0% - 100%
UV Flood 36 2 Channel Mode
Channel Value
Function
1 DIMMER
0 - 255 0% - 100%
2 STROBING
0 - 31 LED OFF
32 - 63 LED ON
64 - 95 STROBING SLOW - FAST
96 - 127 LED ON
128 - 159 PULSE STROBE SLOW - FAST
160 - 191 LED ON
192 - 223 RANDOM STROBE SLOW - FAST
224 - 255 SOUND ACTIVE STROBING
UV Flood 36 Dotz RF Remote Operation
The Dotz Par RF remote (sold separately)
has many different func-
tions and allows you to control your UV Flood 36 from long distance.
The remote can control your system up to 25 meters. To use the
remote you must first activate the fixtures receiver, to activate the re-
ceiver please see the instructions on page 9.
BLACKOUT
-
Pressing this button will blackout the fixture.
COLOR -
This button will activate the UV output. Use the “+” and “-”
buttons to adjust the output intensity.
SOUND ACTIVE -
This button activates sound active mode.