  UV Flood 36                                          Safety Precautions

ADJ Products, LLC  -  www.adj.com  - UV Flood 36 Instruction Manual Page 4

Power Supply:

 The ADJ UV Flood 36 contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into the 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The UV Flood 36 can be controlled via DMX-512 protocol. The UV Flood 

36 has 3 DMX channel modes; 1 channel mode, 2 channel mode, & 

3 channel mode. The DMX address is set on the rear panel of the UV 

Flood 36. Your unit and your DMX controller require a approved DMX-

512 110 Ohm Data cable for data input and data output (Figure 1). We 

recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all professional sound and 

lighting stores). Your cables should be made with 

a male and female XLR connector on either end 

of the cable. Also remember that DMX cable must 

be daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - UV Flood 36 Instruction Manual Page 5

  UV Flood 36                                                              Set Up

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

•   Cleaning -The fixture should be cleaned only as recommended by  

   t he manufacturer. See page 3 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Figure 1

Содержание UV FLOOD 36

Страница 1: ...uct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indi rect economic loss associated with the use or reliance of any information contained within this document and or as a result of the impr...

Страница 2: ...j com UV Flood 36 Instruction Manual Page 2 Unpacking Thank you for purchasing the UV Flood 36 by ADJ Prod ucts LLC Every UV Flood 36 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the ship ping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all ac...

Страница 3: ...t all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC www adj com UV Flood 36 Instruction Manual Page 5 UV Flood 36 Set Up To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water ...

Страница 4: ...ect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior UV Flood 36 Set Up DMX512 IN 3 PIN XLR POWER POWER POWER DMX512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to ...

Страница 5: ...or interrupted the fix ture will stay in the last DMX set up If power is applied and this mode is set the unit will automatically go into the last DMX set up Soun Sound Active If the DMX signal is lost or interrupted the unit will automatically go into sound active mode 3 Find your desired setting and press ENTER Your setting will be saved automatically Activate RF Control This function is used to...

Страница 6: ...annel Value Function 1 DIMMER 0 255 0 100 UV Flood 36 2 Channel Mode Channel Value Function 1 DIMMER 0 255 0 100 2 STROBING 0 31 LED OFF 32 63 LED ON 64 95 STROBING SLOW FAST 96 127 LED ON 128 159 PULSE STROBE SLOW FAST 160 191 LED ON 192 223 RANDOM STROBE SLOW FAST 224 255 SOUND ACTIVE STROBING UV Flood 36 Dotz RF Remote Operation The Dotz Par RF remote sold separately has many different func tio...

Страница 7: ...en reached you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures UV Flood 36 Power Cord Daisy Chain First unplug the power Locate and remove the unit s power cord Once the cord has been removed located the fuse holder located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse holder Remove the bad fuse and ...

Страница 8: ...d or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Products LLC if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintnance cleaning or periodic check up During the period specified above ADJ Products LLC ...

Отзывы: