background image

Power Supply:

 The ADJ Mega Beam Bar contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

a power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega Beam Bar can be controlled via DMX-512 protocol. The Mega 

Beam Bar has 4 DMX channel modes, please see page 8 for the different 

modes. The DMX address is set on the back panel of the Mega Beam Bar. 

Your unit and your DMX controller require a stan-

dard 3-pin XLR connector for data input and data 

output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable (This cable may be purchased at almost all 

pro lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Mega Beam Bar User Manual Page 5

  Mega Beam Bar                                                        Set Up

ADJ Products, LLC  -  www.adj.com  - Mega Beam Bar User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

  Mega Beam Bar                                                        Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Содержание MEGA BEAM BAR

Страница 1: ...six RGB color mixing LED fixtures This fixture can be used in a stand alone mode or connected in a Master Slave configuration This system has six operating modes Sound Active mode Auto Run mode Built...

Страница 2: ...e situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when...

Страница 3: ...Page 5 Mega Beam Bar Set Up ADJ Products LLC www adj com Mega Beam Bar User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug...

Страница 4: ...to set your desired DMX address CHND This will let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displayed press ENTER Either 2CH 4CH 8CH or 10CH will be displ...

Страница 5: ...System Menu Mega Beam Bar System Menu in case the DMX signal is lost the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost You can also set t...

Страница 6: ...asing through the built in programs Show mode Choose 1 of 12 show modes to run DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controll...

Страница 7: ...und sensitivity see page 9 3 The optional UC3 Controller not included may be used to con trol different functions including blackout Show Mode In this mode you can choose 1 of 12 show modes to run 1 T...

Страница 8: ...5 0 100 Mega Beam Bar 8 Channel Mode Channel Value Function 1 RED LEDS 1 2 0 255 0 100 2 GREEN LEDS 1 2 0 255 0 100 3 BLUE LEDS 1 2 0 255 0 100 4 WHITE LEDS 1 2 0 255 0 100 5 RED LEDS 3 4 0 255 0 100...

Страница 9: ...shipped in it s original package No accessories should be shipped with the product If any accessories are shipped with the product ADJ Products LLC shall have no liability whatsoever for loss of or da...

Страница 10: ...el Mode 10 Channel Mode Working Position Any safe working position Warranty 3 Year 1 095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to chan...

Отзывы: