For Your Own Personal Safety, Please Read and Understand This 

Manual Completely Before You Attempt To Install Or Operate 

This Unit!

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Be sure that the local power outlet match that of the required volt-

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been 

   frayed or broken. 

•   Do not attempt to remove or break off the ground prong from    

   the electrical cord. This prong is used to reduce the risk of electrical  

   shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out-

   doors voids all warranties.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to cords at plugs, convenience recep- 

   tacles, and the point where they exit from the appliance. 

•   Cleaning -The fixture should be cleaned only as recommended by  

   the manufacturer. See page 20 for cleaning details.

•   Heat -This fixture should be situated away from heat sources such 

   as radiators, heat registers, stoves, or other appliances (including 

   amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. Objects have fallen, or liquid has been spilled into the appliance.

    B. The appliance has been exposed to rain or water.

    C. The appliance does not appear to operate normally or exhibits a  

     

  

 marked change in performance.

 Jellyfish IR   

                                 Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Jellyfish IR Instruction Manual Page 5

ADJ Products, LLC  -  www.adj.com  - Jellyfish IR Instruction Manual Page 4

 Jellyfish IR  

                                                     Set Up

Power Supply:

 The ADJ Jellyfish IR contains an automatic voltage 

switch, which will auto sense the voltage when it is plugged into the 

power source. With this switch you do not need to worry about wall 

voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures and  the  controller  are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Jellyfish IR can be controlled via DMX-512 protocol. 

The Jellyfish IR has two DMX Channel modes. It has a three chan-

nel mode and 28 channel mode. The DMX address 

is set electronically using the controls on the rear 

panel of the unit. Your unit and your DMX control-

ler  require  a  approved  DMX-512  110  Ohm  Data 

cable for data input and data output (Figure 1). We 

recommend  Accu-Cable  DMX  cables.  If  you  are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable  (This  cable  may  be 

purchased  at  almost  all  professional  sound  and 

lighting stores). Your cables should be made with a male and female 

Figure 1

Содержание Jellyfish IR

Страница 1: ...nds and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipmen...

Страница 2: ...packing Thank you for purchasing the Jellyfish IR by ADJ Prod ucts LLC Every Jellyfish IR has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping ca...

Страница 3: ...j com Jellyfish IR Instruction Manual Page 4 Jellyfish IR Set Up Power Supply The ADJ Jellyfish IR contains an automatic voltage switch which will auto sense the voltage when it is plugged into the po...

Страница 4: ...three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with th...

Страница 5: ...will let you the DMX Mode you want to run You can choose between 3 channel mode and 28 channel mode 1 Press the MENU button until CHND is displayed press ENTER Either 3CH or 28CH will be displayed 2 P...

Страница 6: ...onfirm IDSP This function will reverse the display 180 1 Press the MENU button until IDSP is displayed press ENTER 2 Press ENTER to flip the display Press ENTER to flip it again Press ENTER when you h...

Страница 7: ...roller Sound Active Mode This mode allows either single unit or several units linked together to run to the beat of the music 1 Press the MENU button until SOUN is displayed and press ENTER Press the...

Страница 8: ...outlet They must be the same fixtures DO NOT mix fixtures Jellyfish IR Power Cord Daisy Chaining The UC IR sold separately infrared remote gives you control of various functions See below To control...

Страница 9: ...UES 120 239 0 9 OPEN 10 255 CHASE SPEED SLOW FAST 3 CHANNEL MODE The setting of Channel 1 is used with Channel 2 and Channel 3 Jellyfish IR 3 Channel DMX Traits Channel Value Function 1 COLOR CHASE SO...

Страница 10: ...WHITE 1 255 0 100 25 RED 1 255 0 100 26 GREEN 1 255 0 100 27 BLUE 1 255 0 100 28 WHITE 1 255 0 100 ADJ Products LLC www adj com Jellyfish IR Instruction Manual Page 19 Jellyfish IR 28 Channel DMX Trai...

Страница 11: ...tness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after...

Страница 12: ...olors RGB W Duty Cycle None DMX 2 DMX Channel Modes 3 Channel Mode 28 Channel Mode Sound Active Yes Working Position Any Safe Secure Position Warranty 2 Year 730 days Auto Sensing Voltage This fixture...

Отзывы: