This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit 

will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any 

unit can be configured to act as a Primary or as a Secondary, but only one unit in a given system can 

be programmed to act as the Primary.

Primary-Secondary Connections and Settings:

1.  Daisy chain your units via the XLR connectors on the rear panels of each unit. Use standard XLR 

data cables to link your units together. Remember that the male XLR connector is the input and 

the female XLR connector is the ouput. The first unit in the chain (primary) will use the female XLR 

connector only. The last unit in the chain will use the male XLR connector only.

2.  Use the display screen and control panel to navigate to the Personality > Prim/Sec Mode, and 

press ENTER. 

3.  The fixture can be set to Primary or Secondary. Select one or the other, depending on which mode 

you would like the current fixture to use.

4.  Make sure that only one unit is designated as the Primary, while all other units are designated as 

Secondaries.

5.  The secondary units will act in conjunction with the primary unit. 

P R I M A RY- S E C O N D A RY  S E T   U P

Содержание FOCUS FLEX L19

Страница 1: ...FOCUS FLEX L19 User Manual ...

Страница 2: ... contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product ADJ PRODUCTS LLC World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 800 322 6337 Fax 323 582 2941 www adj com support adj com ADJ Supply Europe B V Junostraat 2 6468 EW Kerkrade Netherlands Tel 31 45 546 85 00 Fax 31 45 546...

Страница 3: ...Device Management RDM 16 System Menu 17 Fan Modes and Low Noise Operation 21 Wireless DMX 22 DMX Setup 24 DMX Addressing 25 DMX Traits Channel Functions Values 26 Pixel Map 35 Virtual Swatch Colors 36 Color Macro Chart 37 Dimmer Curve 38 Primary Secondary Set Up 39 Power Linking Ethernet Linking 40 Cleaning Error Codes Ordering Information 41 Specifications 42 Dimensional Drawings 43 ...

Страница 4: ...CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts adj com US http www adjparts eu EU ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 4...

Страница 5: ... repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect E ADJ Products LLC reserves...

Страница 6: ... x1 Omega Brackets x2 WARRANT Y REG I ST R ATION This device carries a 2 year limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompanied by a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the...

Страница 7: ...ags inside the unit are placed in an OPEN position For superior impact protection the fixture is shipped in a custom fitted high density Foam Inlay FIL This FIL must be used inside the road cases for transportation DO NOT TIP THE CASE OVER AND AVOID ALL SHOCKS AND ROUGH HANDLING ESPECIALLY TIPPING THE PRACTICE OF TIPPING THE FIXTURE CASE OVER TO ITS SIDE AND ONTO A HARD SURFACE THE CASE MUST RIDE ...

Страница 8: ...CLAIMS AND OR REPAIRS DO NOT PLUG FIXTURE INTO A DIMMER PACK NEVER OPEN THIS FIXTURE WHILE IN USE UNPLUG POWER BEFORE SERVICING FIXTURE NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT MAXIMUM AMBIENT TEMPERATURE IS 113 F 45 C DO NOT OPERATE WHEN AMBIENT TEMPERATURE EXCEEDS THIS VALUE UNIT SURFACE TEMPERATURE MAY REACH UP TO 167 F 75 C DO NOT TOUCH THE HOUSING WITH BARE HANDS DURING OPERATION...

Страница 9: ...etween fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always attach an appropriately rated safety cable ALWAYS disconnect fixture from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out ...

Страница 10: ...OVERVIEW DMX In DMX Out Net Out Fuse Power Out Power In Net In Pan Lock Tilt Lock Safety Cable Loop Service Port Display Screen Left Button Down Button Enter Button Right Button Up Button Mode Button 10 ...

Страница 11: ...l equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cables and accessories Overhead fixture installation must always be secured with a secondary safety attachment such as an appropriately rated safety cable that meets all local national and country codes and regulations Fixture a...

Страница 12: ... tilt movement Both locks should be engaged during shipping transporation and installation in order to keep the fixture head secured in place and avoid damage Always make sure to release both locks before powering on and operating the fixture The location of the pan and tilt locks are illustrated below Pan Lock Tilt Lock 12 ...

Страница 13: ...f you lack these qualifications do not attempt the installation yourself NOTE These installations should be checked by a skilled person once a year SAFETY CABLE ALWAYS ATTACH A SAFETY CA BLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS The fixture is fully operational in three different mounting positions hanging upside down mou...

Страница 14: ...TURE Pull the safety cable through the opening located on the bottom of the unit and over the trussing system or a safe fixation spot Insert the end in the carabiner and tighten the safety screw FIXTURE I NSTAL L ATION NOTICE The suitable environmental temperature for this lighting fixture is 14 F to 113 F 10 C to 45 C Do not place this lighting fixture in an environment where the temperatures fal...

Страница 15: ...rs iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guidelines below can prevent any potential damage from occurring if followed Contact ADJ Service for more details DO NOT EXPOSE THE FIXTU...

Страница 16: ...900 Basic 22 1 Standard 31 2 Extended 40 3 Extended 104 4 Standard CMY 25 5 Extended CMY 28 6 Please be aware that not all RDM devices support all RDM features and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all of the fea tures that you require The following parameters are accessible in RDM on this device 0x0011 Proxied Device Count...

Страница 17: ... hold the MODE button for 10 seconds The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press 17 KEY LOCK This function allows the user to configure whether or not the display screen and control panel keys will lock after a certain period of inactivity It can be accessed by navigating to Personality Display Key Lock in the system menu The setting options a...

Страница 18: ...n solid When Wire less DMX is not con nected a red LED indi cator shall be on solid Wireless DMX and DMX Out When Wireless DMX is connected a green LED indicator shall be on solid The DMX XLR output shall send DMX signal out Wireless DMX Settings Wireless DMX Enable ON OFF When Wireless DMX is enabled and con nected a Wireless DMX signal strength indicator bar shall be displayed When Wireless DMX ...

Страница 19: ...andard Fast Select zoom speed Dim Modes Standard Select dim mode and set dimming speed Stage TV Architectural Theatre Stage 2 Dim Speed 0 1s 10s LED Refresh Rate 900 1500 Hz 2500 Hz 4000 Hz 5000 Hz 6000 Hz 10 KHz 15 KHz 20 KHz 25 KHZ 1200 Hz Set LED refresh rate Dim Curve Linear Select dimming curve Square Inv Squa S Curve Reset Motors Reset All Motors Yes No Reset fixture motors Pan Tilt Reset Ye...

Страница 20: ...Hours Total hours fixture has been powered on since last reset P On Time Reset Passcode 050 Reset P On Time R Total LED Time LED On Time xxxxxx Hours Total lifetime hours LED has been pow ered on non resetta ble LED On Time R xxxxxx Hours Total hours LED has been powered on since last reset LED Hours Reset Passcode 050 Reset LED On Time R Fixture Temps LEDs Current xxx F xxx C Current LED temp Max...

Страница 21: ...ls to a minimum The fixture output will only reduce when the LED engine cannot be cooled down to its safe operating range due to high ambient temperature NOTE Recommended for daily operation High Fan speeds are increased throughout for the most efficient cooling of the fixture This mode will increase wear on the fans and should only be utilized in exceptional circumstances Fans will always run eve...

Страница 22: ... DMX address and press ENTER to confirm NOTE Erratic fixture movement may occur if other Wireless DMX products are in use in the same area and are using the same Wireless DMX channel When Wireless DMX is enabled the fixture may immediately start to respond to the DMX wireless signal from another wireless DMX Transceiver Make sure to know what wireless DMX channels are being used in the area where ...

Страница 23: ... device or remote Wireless DMX signal can penetrate walls glass metal and most objects However there are many factors that can effect and or interrupt the wireless DMX signal including the presence of people Therefore it is highly recommended to position the wireless antenna a minimum of 9 8ft 3m above audiences to ensure optimum and reliable wireless DMX operation ...

Страница 24: ...rotocol Your unit and your DMX controller requires a 5 pin XLR connector for data input output We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all pro lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable mus...

Страница 25: ...ct in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the Focus Fle...

Страница 26: ...00 12 12 000 255 Lime 2 0 to 100 13 13 000 255 Red 3 0 to 100 14 14 000 255 Green 3 0 to 100 15 15 000 255 Blue 3 0 to 100 16 16 000 255 Lime 3 0 to 100 17 000 255 Red 4 0 to 100 18 000 255 Green 4 0 to 100 19 000 255 Blue 4 0 to 100 20 000 255 Lime 4 0 to 100 21 000 255 Red 5 0 to 100 22 000 255 Green 5 0 to 100 23 000 255 Blue 5 0 to 100 24 000 255 Lime 5 0 to 100 25 000 255 Red 6 0 to 100 26 00...

Страница 27: ...5 Lime 13 0 to 100 57 000 255 Red 14 0 to 100 58 000 255 Green 14 0 to 100 59 000 255 Blue 14 0 to 100 60 000 255 Lime 14 0 to 100 61 000 255 Red 15 0 to 100 62 000 255 Green 15 0 to 100 63 000 255 Blue 15 0 to 100 64 000 255 Lime 15 0 to 100 65 000 255 Red 16 0 to 100 66 000 255 Green 16 0 to 100 67 000 255 Blue 16 0 to 100 68 000 255 Lime 16 0 to 100 69 000 255 Red 17 0 to 100 70 000 255 Green 1...

Страница 28: ...5 249 8000K 250 255 10000K 11 19 83 10 13 Virtual Foreground Color Wheel 000 Open 001 060 Virtual Swatch Colors see Virtual Swatch Colors section 061 179 Open 180 201 Color Scroll Clockwise fast to slow 202 207 Stop 208 229 Color Scroll Counter Clockwise slow to fast 230 234 Open 235 239 Random Slots Fast 240 244 Random Slots Medium 245 249 Random Slot Slow 250 255 Open 12 20 84 11 14 Virtual Back...

Страница 29: ...40 244 Macro 8 245 255 No function 10 15 23 87 14 17 000 255 Foreground Effect Macro Speed slow to fast 11 16 24 88 15 18 000 255 Foreground Effect Macro Fade min to max 12 17 25 89 16 19 Background Effect Macro 000 Open 001 060 Macro 1 061 179 Macro 2 180 201 Macro 3 202 207 Macro 4 208 229 Macro 5 230 234 Macro 6 235 239 Macro 7 240 244 Macro 8 245 255 No function 13 18 26 90 17 20 000 255 Backg...

Страница 30: ...w to fast 224 255 Shutter open LEDs on 16 21 30 94 21 24 000 255 Dimmer 0 to 100 22 31 95 22 25 000 255 Dimmer Fine 17 23 32 96 23 26 000 255 Zoom wide to narrow 24 33 97 24 27 000 255 Zoom Fine 25 34 98 25 28 Dim Modes 000 020 Default to unit setting 021 040 Standard 041 060 Stage 061 080 TV 081 100 Architectural 101 120 Theatre 121 140 Stage 2 Dimming Speed 141 0 1 s 142 0 2 s 143 0 3 s 144 0 4 ...

Страница 31: ... 010 019 Program 1 020 029 Program 2 030 039 Program 3 040 049 Program 4 050 059 Program 5 060 069 Program 6 070 079 Program 7 080 089 Program 8 090 099 Program 9 100 109 Program 10 110 119 Program 11 120 129 Program 12 130 139 Program 13 140 149 Program 14 150 159 Program 15 160 169 Program 16 170 179 Program 17 180 189 Program 18 190 199 Program 19 200 209 Program 20 210 255 No function 19 28 37...

Страница 32: ... Hz 016 950 Hz 017 960 Hz 018 970 Hz 019 980 Hz 020 990 Hz 021 1000 Hz 022 1010 Hz 023 1020 Hz 024 1030 Hz 025 1040 Hz 026 1050 Hz 027 1060 Hz 028 1070 Hz 029 1080 Hz 030 1090 Hz 031 1100 Hz 032 1110 Hz 033 1120 Hz 034 1130 Hz 035 1140 Hz 036 1150 Hz 037 1160 Hz 038 1170 Hz 039 1180 Hz 040 1190 Hz 041 1210 Hz 042 1220 Hz 043 1230 Hz 044 1240 Hz 045 1250 Hz 046 1260 Hz 047 1270 Hz 048 1280 Hz 049 1...

Страница 33: ...1470 Hz 068 1480 Hz 069 1490 Hz 070 1500 Hz 071 2500 Hz 072 4000 Hz 073 5000 Hz 074 6000 Hz 075 10 KHz 076 15 KHz 077 20 KHz 078 25 KHz 079 No function 080 089 Enable blackout while pan tilt moving 090 099 Disable blackout while pan tilt moving 100 105 Fan Mode Low hold 3s 106 111 Fan Mode High hold 3s 112 117 Fan Mode Auto hold 3s 118 122 Enable Pan Invert hold 3s 123 127 Disable Pan Invert hold ...

Страница 34: ...Ext 22 31 40 104 31 34 Special Functions cont d 170 174 Enable Zoom Speed Fast 175 179 Disable Zoom Speed Fast 180 182 Enable White Calibration hold 3s 183 185 Disable White Calibration hold 3s 186 189 Fan Mode Mute hold 3s 190 193 Enable Zoom Mode 2 hold 2s 194 197 Disable Zoom Mode 2 hold 3s 198 255 No function ...

Страница 35: ...35 PIXEL MA P EXTENDED 40 CH EXTENDED 104 CH RGBL COLUMNS RGBL ROWS 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 3 1 1 4 2 2 3 4 4 4 5 6 6 6 6 7 8 8 9 9 4 6 9 2 8 5 1 3 7 5 1 3 7 9 5 2 8 4 6 ...

Страница 36: ...enta 48 139 Primary Green 9 179 Loving Amber 29 46 Dark Magenta 49 122 Fern Green 10 21 Gold Amber 30 48 Rose Purple 50 89 Moss Green 11 105 Orange 31 126 Mauve 51 124 Dark Green 12 158 Deep Orange 32 49 Medium Purple 52 88 Lime Green 13 22 Dark Amber 33 58 Lavender 53 138 Pale Green 14 778 Millennium Gold 34 199 Palace Blue 54 203 Quarter CT Blue 15 135 Deep Golden Amber 35 119 Dark Blue 55 202 H...

Страница 37: ...93 Color Macro 47 185 188 0 142 208 0 Color Macro 15 57 60 255 96 236 96 Color Macro 48 189 192 52 148 209 0 Color Macro 16 61 64 238 93 255 93 Color Macro 49 193 196 1 134 204 0 Color Macro 17 65 68 163 87 255 87 Color Macro 50 197 200 0 145 212 0 Color Macro 18 69 72 150 90 255 90 Color Macro 51 201 204 0 121 192 0 Color Macro 19 73 76 100 77 255 77 Color Macro 52 205 208 0 129 184 0 Color Macro...

Страница 38: ...ER 100 50 10 0 Time ms 0 Sec 255 255 0 0 Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time Down Time Dimming Curve Ramp Effect 0 sec Fade Time 1 sec Fade Time Rise Time ms Down Time ms Rise Time ms Down Time ms ...

Страница 39: ... link your units together Remember that the male XLR connector is the input and the female XLR connector is the ouput The first unit in the chain primary will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Use the display screen and control panel to navigate to the Personality Prim Sec Mode and press ENTER 3 The fixture can be set to Primary or ...

Страница 40: ...l for use with ArtNet or sACN operation as illustrated below Please refer to the manual for the controller that you are using for information on setup limitations To link the fixtures in this way link the Net Out port of your controller to the Net In port on the first fixture Then link the Net Out port on the first fixture to the Net In port of the next fixture in line and continue until all fixtu...

Страница 41: ...optics with glass cleaner and a soft cloth every 20 days Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew ERROR CO DES Print Error Message Description Error code PAN TILT Zoom Head Fan1 Head Fan2 Base Fan1 Base Fan2 LED Temp Base Temp ORDERING I NF O RMATION SKU US ...

Страница 42: ...lor Wheel Control Built In Color Macros 2 700K 10 000K Linear White Color Temperature Control Color Temperature Presets 2 700 3 000 3 200 4 000 4 500 5 000 5 600 6 500 8 000 and 10 000K Control 6 DMX Modes 22 31 40 104 Standard CMY 31 Extended CMY 34 Color LCD display with 6 button function menu Control DMX512 ArtNet sACN and KlingNet Compatible and wireless DMX Built In Effect Pixel Programs with...

Страница 43: ...WIN GS 3 6in 91mm 14 9in 379mm 16 0in 407mm 14 1in 359mm 5 6in 141mm 7 1in 180mm 11 0in 280mm 14 8in 375mm 11 4in 289mm 11 2in 285mm 11 3in 288mm 18 5in 470mm 8 8in 224mm 12 8in 326mm 9 2in 234mm 4 4in 112mm 16 5in 420mm ...

Страница 44: ......

Отзывы: