SET ADDRESS - In this menu you can find and set your desired DMX address.

DMX CHANNEL MODE - In this menu you can find and set your desired DMX channel mode.

NO DMX STATUS - This menu setting is used as a precaution mode in case the DMX signal is lost 

or interrupted. The operating mode chosen in this menu is the running mode the fixture will go into 

when the DMX signal is lost. Listed below are the 3 modes.
 •  

Hold Last

 - This setting will have the fixture stay in the last DMX setup.   

 •  

Blackout

 - This setting will have the fixture automatically go into stand by mode.

 •  

Manual

 - This setting will go into the current manual control set up. See MANUAL CONTROL.   

DIM MODES - In this menu you are able to select your desired dimmer mode and adjust the dimming 

speed time.

LED REFRESH RATE - In this menu you are able to select your desired LED refresh rate.

GAMMA - In this menu you are able to select your desired gamma setting.

DISPLAY - In this menu you you are able to activate/deactivate the display blackout and activate/deactivate 

the display lock. 

SERVICE - In this menu you are able to access and adjust/change: the calibration (effect adjust) and 

restore the factory settings.

MANUAL CONTROL - This menu is for manual testing and manual control. The dimmer and strobe 

can be tested/adjusted. The fixture must be set to “Manual” under “No DMX State”.

FIXTURE LIFE TIME 
 •  Power On Time -The TOTAL power ON running time of the unit is displayed. This time CANNOT  

  be reset.
 •  P-On Time-R - The CURRENT power ON running time of the unit is displayed. This running time  

  may not be the same as the TOTAL power ON running time displayed under “Power On Time”.  

  This time CAN be reset. NOTE: The displayed time represents the current power ON time  

  since the last reset.
 •  P-On Time-Reset - Reset the CURRENT power ON running time that is displayed under “P-On Time-R”.

Содержание ENCORE BURST RGBW IP

Страница 1: ...User Instructions ENCORE BURST RGBW IP...

Страница 2: ...art 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interfer...

Страница 3: ...eatures I Warranty Registration Safety Guidelines IP65 Notice Overview Installation Connections DMX Set Up DMX Addressing DMX Modes System Menu Multiple Unit Power Linking I Dimmer Curve Chart Dimensi...

Страница 4: ...s contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product re...

Страница 5: ...items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief descri...

Страница 6: ...NTO THE LIGHT SOURCE RETINA INJURY RISK MAY INDUCE BLINDNESS SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK Be sure that the local power outlet is compatible with the required voltage for your unit D...

Страница 7: ...tion against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has...

Страница 8: ...com Encore Burst RGBW IP User Manual Page 7 Encore Burst RGBW IP Overview LCD Screen Mode Button Up Button Down Button Enter Button Safety Cable Rigging Point IP65 5 Pin DMX Out IP65 5 Pin DMX In IP65...

Страница 9: ...ropriately reated professional grade rigging clamp not included to the included Omega Bracket using an M12 screw and nut not included With the rigging clamp securely attached to the Omega Bracket atta...

Страница 10: ...END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE AVAILABLE AT MOST ELECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WA...

Страница 11: ...TA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Encore Burst RGBW IP can be controlled via DMX 512 protocol...

Страница 12: ...ch individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures sim...

Страница 13: ...alf CT Blue Steel Blue Lighter Blue Light Blue Medium Blue Green Dark Green Primary Green Moss Green Fern Green JAS Green Lime Green Spring Yellow Deep Amber Chrome Orange Orange Gold Amber Millennium...

Страница 14: ...2Sec 0 3Sec 0 4Sec 0 5Sec 0 6Sec 0 7Sec 0 8Sec 0 9Sec 1 0Sec 1 5Sec 2 0Sec 3 0Sec 4 0Sec 5 0Sec 6 0Sec 7 0Sec 8 0Sec 9 0Sec 10Sec Default to Unit Setting 000 020 021 040 041 060 061 080 081 100 101 1...

Страница 15: ...Setting 900HZ 1000HZ 1100HZ 1200HZ 1300HZ 1400HZ 1500HZ 2500HZ 4000HZ 5000HZ 6000HZ 10000HZ 15000HZ 20000HZ 25000HZ GAMMA Default to Unit Setting 1 0 2 0 2 2 2 4 2 6 2 8 No Function 11 000 015 016 030...

Страница 16: ...in menu Once in the main menu you can navigate through the different menu s with the UP DOWN and MENU buttons When you reach a field that requires adjusting press the ENTER button to access that field...

Страница 17: ...l Running Time Not Resettable Total Running Time Resettable Reset Total Running Time Current Software Version Current DMX Values Current Temperature Total LED On Running Time Not Resettable LED On Run...

Страница 18: ...D REFRESH RATE In this menu you are able to select your desired LED refresh rate GAMMA In this menu you are able to select your desired gamma setting DISPLAY In this menu you you are able to activate...

Страница 19: ...URE TEMPS Current The current unit temperature is displayed Max Resettable Maximum temperature that has been recorded before reset and after reset This temperature may not be the same as the temperatu...

Страница 20: ...ER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE CHECK SILK SCREEN FOR MAX AMPS Encore Burst RGBW IP Dimmer Curve Chart DIMMER 100 50 10 0 Time ms 0 Sec 255 255 0...

Страница 21: ...cables are connected to the right connectors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be c...

Страница 22: ...and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to...

Страница 23: ...working position Power Draw 121W Weight 8 lbs 3 6 Kgs Dimensions 9 21 L x 9 8 W x 12 12 H 234 x 249 x 308mm DMX Channels 5 DMX Modes 4 6 7 8 11 Warranty 2 Year 730 days Please Note Specifications and...

Отзывы: