2/2
B 340
Water cooling connection
GB 02926 - Edition 05 - 03/2013
Assembly with a
water valve
Water inlet
valve inlet
fitting
Water
outlet
- Provide a water inlet pipe
and a tap to adjust the flow
rate.
- Connect the water valve to
the water inlet line using a
flexible tube following the
assembly diagram:
- Connect the other nipple
to the draining circuit.
Standard assembly
Water OUT
Water IN
- Provide a water inlet pipe and a
tap to adjust the flow rate.
- Connect the water inlet line to
one of the cooler water fittings
1/4 NPT female on the pump,
with the other fitting connected
to the water draining circuit via a
tube (supplied by customer).
adixen Vacuum Products - Operating Instructions - ATP 2300 M