C 20
Detailed description of RS 485
commands
NSP
Switches the speed set point to the nominal speed value
Syntax
#adrNSP<CR>[LF]
This command allows to restore the nominal speed to the default
value : (80 Hz for ACP 28/40 and 100 Hz for ACP 15).
Result
#adr,ok
RPM
Defines the speed set point in stand-by mode
Syntax
#adr RPM nnnn<CR>[LF]
nnnn speed value in rpm
Set point speed from 2100 rpm ( 35 Hz) ( to maximum speed by
step
of 10 rpm.
Max. speed : ACP15: 6000rpm (100 Hz) ; ACP 28/40 or RVP :
4800 rpm (80 Hz).
Note: you must send the SBY command, before changing
the pump rotational speed using RPM command.
Result
#adr, ok or #adr, Errx
x = 1 out of range, 2: parameter error , 3: context error.
SBY
Switches the speed set point to the stand-by value
Syntax
#adrSBY<CR>[LF]
Resets the stand-by speed to the default value (35Hz for all pump
models).
Result
#adr, ok
Note : you must send the SBY command before changing
the pump rotational speed using the RPM command.
ACP
Defines the operating status of the pump
Syntax
#adrACP ON<CR>[LF] : start pump rotation
#adr OFF<CR>[LF] : stop pump
Result
#adr, ok or
#adr, Err3 if the pump is already in the requested state (context
error).
2/3
Содержание ACP 15
Страница 1: ......
Страница 12: ...Dimensional drawing mm inch ...
Страница 16: ...Dimensional drawing mm inch ...
Страница 21: ...B 00 Safety instructions Alcatel Vacuum Technology France Manuel de l Utilisateur ACP 15 28 40 Series 2 1 5 ...
Страница 45: ...G10 ACP 15 15 G pumping curves ...
Страница 46: ...G11 ACP 28 28 G pumping curves ...
Страница 47: ...G12 ACP 40 40 G pumping curves ...
Страница 49: ...G 101 52 SEMI Certificate 1 1 Alcatel Vacuum Technology France Manuel de l Utilisateur ACP 15 28 40 Series 2 ...